IFM Modbus-SL interface module, Enerlin'X

IFM Modbus-SL interface module, Enerlin'X

This IFM is a Modbus interface module, and it is part of EnerlinX communication system. It is required for connection of Masterpact, Compact and PowerPact circuit breakers to a Modbus Serial Line network. Once connected, the circuit breaker is considered as a slave by the Modbus master. The Modbus address is easily set with two rotary switches on its front face. It is equipped on the top with one 24VDC screw clamp terminal block and one RJ45 socket for Modbus Serial line. It is equipped on the bottom with two RJ45 sockets for ULP internal network connection (Universal Logic Plug). The IFM interface is a DIN rail mounting device and its dimensions are 18mm x 72mm x 96mm. The protection degree is IP4x on the front face and IP2x on the connectors. The IFM interface is entirely part of the EcoStruxure Power architecture. The IFM interface firmware can be updated using EcoStruxure Power Commission software.

Product identifiers

SKU: LV434000
EAN: 3606481201683
GTIN: 3606481201683
MPN: LV434000

V+ Loyalty points:

88

Price: £ 281.00 Excl. VAT

Videos

How to video

Specifications

Depth 73 mm
Width 18 mm
Height 109 mm
IO link master no
System accessory yes
Supply voltage DC
Radio standard GSM no
Radio standard LTE no
Radio standard UMTS no
Rack-assembly possible yes
Supply voltage AC 50 Hz
Radio standard Bluetooth no
With potential separation no
SIL according to IEC 61508 None
Number of HW-interfaces CAN 0
Supporting protocol for ASI no
Supporting protocol for KNX no
Number of HW-interfaces other 0
Suitable for safety functions no
Wall mounting/direct mounting yes
Number of HW-interfaces RS-422 0
Supporting protocol for Modbus yes
Supporting protocol for TCP/IP no
Number of HW-interfaces parallel 0
Supporting protocol for EtherCAT no
Supporting protocol for PROFIBUS no
Appendant operation agent (Ex ib) no
Supporting protocol for DeviceNet no
Explosion safety category for dust None
Supporting protocol for EtherNet/IP no
Supporting protocol for SafetyBUS p no
Supporting protocol for PROFINET CBA no
Supporting protocol for DeviceNet Safety no
Certified for UL hazardous location class I no
Supporting protocol for Foundation Fieldbus no
Certified for UL hazardous location class III no
Certified for UL hazardous location division 1 no
Supporting protocol for AS-Interface Safety at Work no
Certified for UL hazardous location group B (hydrogen) no
Fieldbus connection over separate bus coupler possible no
Certified for UL hazardous location group E (metal dusts) no
Certified for UL hazardous location group G (non-conductive dusts) no