2009 wiring accessories domestic circuit protection ELECTRIUM SALES LIMITED  A SIEMENS COMPANY EXPORT SALES Commercial Centre, Lakeside Plaza, Walkmill Lane, Bridgtown, Telephone: +44 1543 455049  Facsimile: +44 1543 455048   Cannock WS11  0XE. eMail: [email protected] eMail: [email protected]  Web: www.electrium.co.uk TECHNICAL DUBLIN OFFICE Telephone: 01543 438330  Facsimile: 01543 438321 Telephone: +353 1 4513303  Facsimile:+353 1 4513242 eMail: [email protected] UK SALES  DUBAI OFFICE  Telephone: 01543 455030   Facsimile: 01543 455031 Telephone: +971 4 3660395  Facsimile:+971 4 3660019 eMail: [email protected] Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication, specifications and performance data are constantly changing. Latest details can be obtained from Volex. Publication No.V2022 Printed in England. Covers  4/9/08  03:29  Page 1

Electrium Sales Ltd. T erms & Conditions 73 HOME 1 Contract Terms Quotations & Orders 1.1 Unless other terms and conditions are expressly accepted by Electrium by means of a specific written amendment heretosigned by Electrium or a Director of Electrium the contract willbe on the terms and conditions set out below (“the ContractTerms”) to the exclusion of any other terms and conditions(except those implied in favour of a seller which are not incon-sistent with the Contract Terms) whether or not the same areendorsed upon, delivered with or referred to in any purchaseorder or other document delivered or sent by the Customer toElectrium or by Electrium to the Buyer reference made byElectrium to the Customer’s order, specification or like docu-ment will not be deemed to imply that any terms or conditionsendorsed upon, delivered with or referred to in such order,specification or like document will have effect to the exclusionor amendment of the Contract Terms. No variation, addition ormodification of the Contract Terms conditions shall be bindingon Electrium unless such variation, addition or modification beagreed to in writing under the signature of a Director ofElectrium. 1.2 Any quotation is given on the basis that no contract will come into existence until the Customer places an order pursuantthereto. Any quotation is valid for a period of 30 days only fromits date provided that Electrium has not previously withdrawn it. 2 Price The price of Goods supplied hereunder (“the Goods”) is exclusive ofVAT or any successor tax thereto unless otherwise agreed in writing.The price for the Goods shall be (unless otherwise agreed byElectrium in writing) the list price of Electrium current at the date ofdespatch and in the case of an order for delivery by instalments theprice payable for each instalment shall be Electrium’s list price cur-rent at the date of despatch for each instalment. All prices are basedon standard pack sizes and quantities and Electrium reserves theright to levy an additional charge if such packs must be broken up tofulfil an order.The price of Goods is inclusive of costs of carriage tothe Customer’s premises in Great Britain and Northern Irelandexcept on individual orders having a net value calculated by referenceto the Company’s most recent price list of less than £200 (excludingVAT) which shall be subject to an additional charge of not less than£15.00 (excluding VAT) to cover carriage and packing.The price ofGoods is based on the costs of materials, labour, sub-contracts, trans-port, taxes, duties and currency exchange rates ruling at the date ofthe quotation. Electrium reserves the right to amend the contractprice to take account of any variations in these costs or the imposi-tion of any new taxes or duties occurring from whatever causebefore delivery of the Goods. 3 Payment The due date for payment shall be the last day of the month follow-ing the month of despatch of Goods supplied by Electrium. Paymentmade before the due date for payment shall be subject to a settle-ment discount of 2.5%.VAT is calculated on the discounted value ofthe invoice and is not subject to settlement discount. Interest at anannual rate of 3% per month will accrue daily and be calculated on adaily basis on overdue accounts from the date of invoice until pay-ment. Notwithstanding any Contract Term allowing the Customercredit payment shall become due and payable to Electrium immedi-ately upon the termination of the contract.The Customer shall notbe entitled to exercise any right of set-off or lien or any similar rightor claim in connection with the Goods or the price payable therefor. 4 Packing Materials Packing cases and cartons will be provided free of charge byElectrium. All pallets used shall remain at all times the property ofElectrium and are to be returned to Electrium on demand in goodcondition. Electrium reserves the right to alter the method of pack-ing without reference to the Customer. 5 Damage or Loss in Transit Electrium will not be liable in respect of any damage or discrepancy,shortage or loss in transit or any claim that the Goods delivered donot otherwise comply with the contract unless the Customer shallhave informed the Company in writing, telex or facsimile as follows:(a) Within three days of delivery in the event of any damage, dis-crepancy or shortage. (b) Within seven days of delivery in the event that the Goods donot comply with the contract, and(c) Within twenty-one days of receipt of the Company’s invoice inthe event of non-delivery. Where the Goods are accepted from the Company’s carriers theyshall be deemed to have been checked by the Purchaser and accept-ed unless the delivery receipt is signed and endorsed ‘unexamined’and the packing and its contents are retained for later inspection. 6 Delivery The place of delivery for Goods shall be the Customer’s premises oras otherwise agreed by Electrium in writing.The time of delivery willbe as agreed between the parties or if no such agreement has beenreached will be within a reasonable time and the Company will beentitled to make delivery by instalments. In no circumstances willElectrium be liable for loss or damage of any kind whatsoever causeddirectly or indirectly by any delay in the delivery of Goods, norunless such delay exceeds 180 days will any delay entitle theCustomer to terminate or rescind the contract. Notwithstanding anyother Contract Term, risk in the Goods shall pass to the Buyer whenthe Goods are delivered to the Customer or its agent. 7 Title of Goods Until Electrium has been paid in full for the Goods comprised in thisand/or any other contract between the Customer and Electrium, theCustomer shall hold the Goods in a fiduciary capacity as bailee forElectrium and:(i) the title to, ownership of, and the property in, the Goods shallremain vested in Electrium (notwithstanding delivery of thesame and parting of the risk therein to the Customer) until pay-ment in full for all Goods comprised in this and every othercontract between Electrium and the Customer has beenreceived by Electrium. (ii) The Customer shall be in possession of the Goods asElectrium’s bailee. If so required the Customer shall store theGoods for Electrium without charge to Electrium separate fromany goods which are the property of the Customer and/or anythird party and ensure that they are clearly marked and identi-fied as belonging to Electrium. (iii) Electrium reserves the right to require the Customer to return the Goods and may recover and sell the same at any time. Forthat purpose Electrium’s servants and agents together with all necessary and appropriate transport shall be entitled to unre-stricted access to the Customer’s premises and any other loca-tion where the Goods are situated to take possession of theGoods and, if necessary, dismantle the Goods from any articleor articles to which they may have been attached and toremove the Goods from the Customer’s premises. (iv) Prior to the property in the Goods passing to the Customer Electrium permits the Customer to deliver the Goods to athird party pursuant to a bona fide and arms-length agreementto re-sell the Goods and allows the Customer to convert orincorporate the Goods into or mix the Goods with othergoods but such liberty will cease upon the termination of thecontract. (v) Where Electrium is unable to determine whether any goods areElectrium’s Goods the Customer shall be deemed to have soldall goods of the kind sold by Electrium to the Customer in theorder in which they were invoiced to the Customer. 8 Descriptive Matter Descriptive matter, illustrations, dimensions and weights issued byElectrium are to be regarded as being for guidance only and cannotbe held as binding in any way. In pursuance of Electrium’s policy ofproduct improvement Electrium reserves the right to alter patternsand designs without prior notice. 9 Guarantee Electrium will make good by replacement (or its option by repair)defects which under proper use appear in the Goods within a periodof twelve calendar months after the Goods have been despatched,and which arise solely from faulty design, materials or workmanshipprovided always that defective Goods have been returned toElectrium and Electrium was notified of the defect or suspecteddefect immediately the same became known to the Customer.Thecost of carriage on such returned Goods and the cost of re-deliveryof the repaired or new Goods to be borne by Electrium. Save for theElectrium’s control equipment which has been correctly repaired ormodified by the use of standard parts supplied by Electrium for suchpurpose, Electrium excludes all liability in respect of any Goodswhich have been re-finished and dismantled or altered in any way orif the Goods were improperly installed or connected or if theCustomer fails to observe or perform the requirements of any main-tenance procedures relating to the Goods. Any Goods replaced willbelong to Electrium. Any repaired or replacement Goods will beguaranteed on these terms for the unexpired portion of the twelvemonth period. In addition, the obligations of Electrium under thiscondition will not apply if the Customer is in breach of this or anyother contract with Electrium. Subject to this condition, all condi-tions, warranties and representations, whether express or implied (bystatute or otherwise) relating to the Goods are hereby excludedinsofar as the same can be excluded without such exclusion beingvoid or unenforceable.Electrium will be under no liability under the contract for any per-sonal injury, death, loss or damage of any kind whatsoever (otherthan death or personal injury resulting from Electrium’s negligence)whether consequential or otherwise including but not limited to lossof profits and Electrium hereby excludes all conditions, warrantiesand stipulations express or implied, statutory, customary or other-wise which but for such exclusion would or might subsist in favourof the Customer except that such exclusion will not apply to anyimplied condition that Electrium has or will have the right to sell theGoods when the property is to pass; or when Electrium deals as aconsumer (as defined in section 12 of the Unfair Contract Terms Act1977), any implied term relating to the conformity of the Goods withtheir description or sample or as to their quality or fitness for a par-ticular purpose. In no circumstances will Electrium or its employees,agents or sub-contractors be liable for any loss or damage of anykind whatsoever (other than death or personal injury resulting fromElectrium’s negligence) whether consequential or otherwise causeddirectly or indirectly by any negligence or other tortious act orbreach of statutory duty on the part of Electrium or on the part ofany of its employees, agents or sub-contractors in connection withor arising out of the manufacture or supply of the Goods or in con-nection with any statement given or made (or advice not given ormade) by or on behalf of Electrium. 10 Patents Electrium will indemnify the Customer against any claim of infringe-ment of letters patent, registered design, trademark or copyright(existing at the date of the contract) arising from the use or sale ofany article or materials supplied by Electrium to the Customer andagainst all costs and damages which the Customer may incur in anyaction for such infringement or for which the Customer maybecome liable in any such action provided always that this indemnityshall not apply to any infringement which arises in connection withany design or instruction issued or given by the Customer toElectrium or to the use of such article or material in a manner orfor a purpose outside the UK or to any infringement which is due tothe use of such article or material in association or combination withany other article or material not supplied by Electrium and providedalso that this indemnity is conditional on the Customer making noadmission in respect of such alleged infringement and givingElectrium the earliest possible notice in writing of any claim beingmade or action threatened or brought against the Customer and onthe Customer permitting Electrium at Electrium’s expense to con-duct any litigation that may ensue and all negotiations for the settle-ment of a claim.The Customer warrants that any design or instruction issued orgiven by the Customer shall not be such as will cause Electrium toinfringe any letters patent, registered design, trademark or copyrightin the execution of the Customer’s order and the Customer agreesto indemnify and keep Electrium indemnified against all liability in theevent that such warrant is found to be untrue, misleading or breached. 11 Advice Advice which Electrium or its agents may give to the Customer shallbe given in good faith but Electrium shall not be liable for any loss ordamage arising directly or indirectly therefrom or attributable there-to unless contained in any written representation or statementissued directly by Electrium. 12 Safety The Customer shall ensure that any modifications whatsoever madeto the Goods supplied hereunder comply with the requirements ofany applicable Safety Regulations. Plugs supplied hereunder shall beso connected as to ensure that they are safe and in full compliancewith any applicable Safety Regulations. The Customer shall ensurethat any kits supplied hereunder are so assembled as to ensure thatthe assembled product is safe and complies with the requirements ofany applicable Safety Regulations.Without prejudice to the aboveprovisions, where Electrium provides the Customer with information about the use for which Goods are designed and have been testedand about any conditions to ensure that when put to that use theywould be safe and without risk to health, the Customer shall use theGoods accordingly and comply with the said conditions.To be prop-erly used the Goods shall be selected, installed, commissioned andmaintained in accordance with good engineering practice and underthe supervision of suitably qualified personnel. 13 Statutory and other Regulations If the cost to Electrium of performing its obligations under any con-tract shall be increased or reduced by reason of making or amend-ment after the date of its quotation of any law or of any other order,regulation or bye-law having the force of law that shall affect the per-formance of Electrium’s contractual obligations, the amount of suchincrease or reduction shall be added to or deducted from the con-tract price as the case may be. 14 Cancellation If the Customer cancels, extends or delays or purports to cancel,extend or delay the contract or part thereof, or fails to take deliveryof any Goods at the time agreed (if any) or if no time is agreed with-in a reasonable time, then the Customer will be liable (without preju-dice to any other rights of Electrium to claim damages) to indemnifyand keep indemnified Electrium against any resulting loss, damage orexpense incurred by Electrium in connection with the supply or non-supply of the Goods including the cost of any material, used orintended to be used therefor and the cost of labour and other over-heads including a percentage in respect of profit. If Electrium isunable (whether temporarily or permanently) to procure any servic-es or goods necessary to enable it to supply the Goods or if thesupply of the Goods is prevented or hindered by reason of any causebeyond Electrium’s reasonable control which for the avoidance ofdoubt and without prejudice to the generality of the foregoing shallinclude governmental action, war, riot, civil commotion, fire, flood,epidemic, labour disputes including labour disputes involving thework force or any part thereof of Electrium, restraints or delaysaffecting shipping or carriers, currency restrictions and Act of God,Electrium may cancel the contract by notice in writing to theCustomer so far as it relates to Goods not then supplied or worknot then done and such cancellation shall not give rise to any claimsby the Customer provided that the Customer shall remain liable topay for Goods delivered prior to the date of such cancellation. 15 General (a) The headings herein are inserted for convenience only and shallnot affect the interpretation of the Contract Terms. (b) Should any clause contained in the Contract Terms be held tobe invalid such invalidity will not affect the validity of theremaining clauses. (c) Any dispute arising out of this contract or the Contract Termsshall be referred in writing to an independent arbitrator whoshall be appointed by agreement between Electrium and theCustomer or in default of agreement by the President for thetime being of the Institute of Electrical Engineers whose deci-sion shall be binding on both parties. (d) The formation, interpretation and operation of the contract willbe subject to English Law and the Customer submits himself tothe non-exclusive jurisdiction of the English Courts. (e) Electrium will be entitled to assign sub-contract or sub-let thecontract or any part thereof. (f) Failure by Electrium to enforce any  of the Contract Terms will not be construed as a waiver of any of its rights here-under. EXPORT All Contract Terms set out above apply to overseas transactions (iesales outside the United Kingdom), where appropriate, except thefollowing:1.2 Any quotation is given on the basis that no contract will come into existence until Electrium despatches an acknowledgementof order to the Customer. Any quotation is valid for a period of 30 days only from its date provided that Electrium has notpreviously withdrawn it. 2 Price The price of Goods includes the cost of packing for shipment FOBBritish Port or Airport except that orders having a net value of £500and below shall be subject to an additional charge to cover packingand carriage. No allowance will be made in lieu of transportation ifthe Customer accepts delivery at the factory, container depot or atany other inland destination or provides his own transportation orwhere packing of a lesser standard is required. 3 Payment First orders from overseas Customers should be accompanied bybank references to enable payment terms to be agreed. Unless oth-erwise agreed in writing, payment is due on delivery. Goods shall bedeemed to have been delivered when the invoice has been presentedin the United Kingdom accompanied by the appropriate documentsof title. 16 Others The Goods will be sold FOB British Port or Airport and the Sellerwill be under no obligation to give the Buyer notice as specified inSection 32(3) of the Sale of Goods Act 1979. CIF or C & F arrange-ments can be made if requested by the Customer, at cost, andElectrium will, on receipt of Customer’s indemnity, take all reasonablesteps to recover from the Underwriters any loss or damage forwhich they may be liable.The Customer shall be solely responsible for complying with all legis-lation and regulations governing the importation of the Goods intothe country of destination including import and export licences andthe payment of duties thereon including but not limited to customsduties and VAT.The Customer shall indemnify Electrium against allcosts claims and demands arising out of any breach by the Customerof this Agreement. CONDITIONS OF USEThe products listed in this publication should be installed by suitablyqualified personnel in accordance with the requirements of relevantlegislation, regulations (including the IEE Wiring Regulations) and theaccepted practice in the industry. Any further information which maybe required about the use for which any specific product has beendesigned and tested, or about conditions of use, is available onrequest. In pursuance of our policy of continuing product improve-ment, equipment described in this publication is subject to changewithout notification. Covers  4/9/08  03:29  Page 2

Switches & Dimmers 02 Power & Control 06 Communications: TV, Telephone & Data 14 Ceiling Accessories 18 Installation Boxes 22 Grid System 24 Metal Plate 28 Flat Plate 34 Decorative Brass 40 Metalclad 44 Weatherproof 48 Interiors 52 Protector : RCD Wiring Accessories 54 Protector : Consumer Units 56 Technical Data 63 Numeric Index 70 Contents Volex Accessories has always been a namesynonymous with reliability and value. Committed toadding extra quality features and contemporaryaesthetics to its designs, Volex has recently launched anew generation of products which combine the latestlooks with value for money and product featurescustomers expect. Volex is part of Electrium, one of the UK’s largestindependent electrical groups, which has offices andmanufacturing sites in the UK, India, China and theMiddle east. All Volex products comply with the applicable British Standard specification and should be installed by suitably qualified personnel in accordance with the requirements of relevant legislation, regulations (including IEE Wiring Regulations) and the accepted practice in the industry. The products listed or described in this publication may be protected by one or more patents, and/or registered designs and/or applications. A full list of patents registered designs and applications may be obtained from the company secretary of Electrium Limited. Left:Electrium’s purpose built Commercial Centrein Cannock, Staffordshire. This publication has been printed on paper that originates from a  forest that is responsibly managed, using vegetable based inks. 2009 Volex 76pp  11/9/08  08:21  Page 1

2009 Volex 76pp  5/9/08  13:38  Page 2

Switches & Dimmers 3 Undergoing a minimum of50,000 operations, the Volex10AX switch design combinesperformance, reliability andsafety.• The silver nickel contact tip ensures a longer life. • A minimum 3mm contact gap ensures added safety. • The arc shield minimises visible arc flash whenoperating the switch. Volex provides a comprehensive range ofplate switches to control lighting fordomestic and commercial applications.The 1000 series wall switches are ratedat 10AX therefore making them ideal forswitching incandescent and fluorescentlighting. Also included in the range are avariety of wide rocker switches 2009 Volex 76pp  5/9/08  13:38  Page 3

Switches  &  Dimmers 10AX WALL  SWITCHES LIST NO DESCRIPTION CARTON QTY VX1010 1 gang 1 way switch 10 VX1020 1 gang 2 way switch 10 VX1030 1 gang intermediate switch 10 VX1040 2 gang 2 way switch 10 VX1050 3 gang 2 way switch 10 VX1054 4 gang 2 way switch 5 • BS EN 60669-1• Terminals suitable for 4x1.0mm 2 , 3x1.5mm 2 or 1x2.5mm 2 conductors • 3mm contact gap• Fully rated at 10AX for fluorescent or inductive loads• Two way switches can be wired as one wayDimensions 1–3 gang: 85mmx85mm with 60.3mm fixing centres4 gang: 145mmx85mm with 120.6mm fixing centres Mounting boxes Surface moulded: 1–3 gang VX9404; 4 gang VX9412Flush metal: 1–3 gang SB623; 4 gang SB665 4 VX1010 VX1040 VX1050 VX1054 VX4020 VX4040 VX1000 10A RETRACTIVE SWITCH LIST NO DESCRIPTION CARTON QTY VX1000 1 gang bell push with bell symbol 10 VX1000/LP 1 gang printed Light/Push 10 VX1000/P 1 gang printed Push 10 • BS EN 60669-1• Terminals suitable for 4x1.0mm 2 , 3x1.5mm 2 or 1x2.5mm 2 conductors • can be wired for normally open (N/O) or normally closed (N/C) circuits Dimensions 85mmx85mm with 60.3mm fixing centres Mounting boxes Surface moulded:VX9404Flush metal: SB623 VX2060 VX2062 6AX ARCHITRAVE  SWITCHES LIST NO DESCRIPTION CARTON QTY VX2060 1 gang 1 way switch 10 VX2061 1 gang 2 way switch 10 VX2062 2 gang 2 way switch 10 • BS EN 60669-1Dimensions 1G: 32mmx86mm2G: 32mmx146mm Mounting boxes Surface moulded: 1 gang VX9401  2 gang VX9402Flush metal: 1 gang 9257  2 gang 9258 10AX WIDE  ROCKER  SWITCHES LIST NO DESCRIPTION CARTON QTY VX4020 1 gang 1 way switch 10 VX4030 1 gang Intermediate switch 10 VX4040 2 gang 2 way switch 10 VX4000 Retractive switch 10 • BS EN60669-1Dimensions 85mmx85mm with 60.3mm fixing centres Mounting boxes Surface moulded:VX9404Flush metal: SB623 2009 Volex 76pp  5/9/08  13:38  Page 4

Switches  & Dimmers 5 VX9001 VX0250PU VX0400PU 6AX CEILING SWITCH LIST NO DESCRIPTION CARTON QTY VX9001 1 way ceiling switch 10 VX9002 2 way ceiling switch 10 VX9009 Cord & acorn for ceiling switches 50 • BS EN 60669-1• Supplied with pull cord• 50.8mm fixing centres 250W DIMMER SWITCHES LIST NO DESCRIPTION CARTON QTY VX0250PU 1 gang dimmer mainsonly 10 VX0252PU 2 gang dimmer mainsonly 5 VX0250LV 1 gang dimmer mains/low voltage 10 VX0252LV 2 gang dimmer mains/low voltage 5 • BS EN 60669-1, BS EN 55014• Dimmers can be used 1 or 2 way Dimensions 86mmx86mm with 18.5mm plate depth Mounting boxes Surface moulded:VX9409Flush metal:SB655 400W DIMMER SWITCH LIST NO DESCRIPTION CARTON QTY VX0400PU 1 gang dimmer mainsonly 10 VX0402PU 2 gang dimmer mainsonly 5 VX0400LV 1 gang dimmer mains/low voltage 10 VX0402LV 2 gang dimmer mains/low voltage 5 • BS EN 60669-1, BS EN 55014• Dimmers can be used 1 or 2 way Dimensions 86mmx86mm with 18.5mm plate depth Mounting box Surface moulded:VX9409Flush metal: SB655 2009 Volex 76pp  5/9/08  13:38  Page 5

2009 Volex 76pp  5/9/08  13:38  Page 6

P o w er & Contr ol 7 The extensive range of power and control accessories is suitable for any residential installation.The range incorporates such features as wide rockers for easy operation, an arc shield, which minimises visible arc flash and positive switching mechanism to prevent balancing between the on and off positions. A product marking service is also available on 13A fused connection units as well as 20A and 45A control switches. 2009 Volex 76pp  5/9/08  13:38  Page 7

P o w er  &  Contr ol 13A SOCKET OUTLETS LIST NO DESCRIPTION CARTON QTY VX1300 1 gang SP switched socket 10 VX1300/D 1 gang DP switched socket 10 VX1400 1 gang SP switched socket with neon 10 VX1500 2 gang SP switched socket 5 VX1500/D 2 gang DP switched socket 5 VX1600 2 gang SP switched socket with neon 5 VX1700 2 gang DP switched socket with outboard rockers 5 VX1800 2 gang DP switched socket with outboardrockers & neon 5 VX9100 1 gang unswitched socket 10 VX9200 2 gang unswitched socket 5 VX9230 3 gang unswitched socket, fused 13A 5 VT1507 1-2 gang conversion socket 1 • BS1363• Terminals suitable for up to 3x2.5mm 2 or 2x4mm 2 conductors • 2 gang DP comes with twin earth as standard Dimensions 1 gang: 85mmx85mm with 60.3mm fixing centres2 gang: 145mmx85mm with 120.6mm fixing centres3 gang: 205mmx85mm with 181mm fixing centres Mounting boxes Surface moulded: 1 gang VX9409; 2 gang VX9414; 3 gang VX9403Flush metal: 1 gang SB655; 2 gang SB665; 3 gang SB646Flush dry lining: 1 gang SB619; 2 gang SB629 8 VX1400 VX1500 LOUNGE PLATE LIST NO DESCRIPTION CARTON QTY VX1590WH Lounge Plate 10 •  BS1363• Terminals suitable for up to 3x2.5mm 2 or 2x4mm 2 conductors Dimensions 267mmx250mm 180mm fixing centres Mounting boxes Flush metal: 35mm SB695, 56mm SB1590 VX1590WH VT1092 VT1108 VT1208 13A 30mA RCD PROTECTED SOCKETS & FCU LIST NO DESCRIPTION CARTON QTY VT1108 1 gang switched RCD protected socket outlet 1 VT1208 2 gang switched RCD protected socket outlet 1 VT1092 RCD Fused Connection Unit 1 • Socket outlets to BS7288• FCU to BS4293• Double pole switching• Terminals suitable for up to 3x2.5mm 2 or 2x4.0mm 2 conductors Dimensions 1G & FCU: 86mmx86mm with 60.3mm fixing centres2G: 146mmx86mm with 120.6mm fixing centres Mounting boxes Surface moulded: 1G & FCU:VX9405   2G:VX9417Flush metal: 1G & FCU: SB615   2G: SB625 VX1700 2009 Volex 76pp  5/9/08  13:38  Page 8

P o w er  & Contr ol 9 ROUND PIN SOCKET OUTLET LIST NO DESCRIPTION CARTON QTY VX9900 15A switched socket 10 VX9901 2A 3 pin socket 10 VX1904 16A 2 pin socket (for export only) 10 VX1906 16A 2 pin switched socket (for export only) 10 VX1907 16A 2 pin twin switched socket (for export only) 5 • BS546 (VX9900,VX9901), BS5733Dimensions 1 gang: 85mmx85mm with 60.3mm fixing centres2 gang: 145mmx85mm with 120.6mm fixing centres Mounting boxes Surface moulded:VX9409. Flush metal:SB655 VX9900 VX1904 VX1081 VX1090 13A FUSED CONNECTION UNITS WITH OPTIONALFLEX OUTLET LIST NO DESCRIPTION CARTON QTY VX1080 DP switched 10 VX1081 DP switched with neon 10 VX1090 Unswitched 10 VX1091 Unswitched with neon 10 • BS1363• Terminals suitable for up to 3x2.5mm 2 or 2x4mm 2 conductors • Fitted with knockout position at bottom edge of plate• Cord outlet suitable for flexible cord up to 10mm 2 diameter Dimensions 85mmx85mm with 60.3mm fixing centres Mounting boxes Surface moulded:VX9409. Flush metal: 1 gang SB655 VX1080WM FUSED CONNECTION UNIT MARKING SERVICE EXAMPLES LIST NO MARKING  VX1080BO BOILER VX1080HD EXTRACTOR HOOD VX1080DW DISH WASHER VX1080EF EXTRACTOR FAN VX1080FR FRIDGE VX1080FZ FREEZER VX1080FF FRIDGE FREEZER VX1080HB HOB LIST NO MARKING  VX1080HT HEATING VX1080MW MICROWAVE VX1080TD TUMBLE DRYER VX1080WD WASTE DISPOSAL VX1080WDR WASHER DRYER VX1080WM WASHING MACHINE VX1080WH WATER HEATER Marking to customer specification also availableCarton Quantity 10 6A THREE POLE CONTROL SWITCH LIST NO DESCRIPTION CARTON QTY VX1013 3 pole isolating switch marked withisolator and fan symbol 10 • BS3676, BS EN 60947-3• 250V only Dimensions 85mmx85mm with 60.3mm fixing centres Mounting boxes Surface moulded:VX9404Flush metal: 1 gang SB623 VX1013 2009 Volex 76pp  5/9/08  13:38  Page 9

P o w er  &  Contr ol 10 20A DP CONTROL SWITCHES WITH OPTIONALFLEX OUTLET LIST NO DESCRIPTION CARTON QTY VX1070 DP switch 10 VX1070WH DP switch marked ‘Water Heater’ 10 VX1060 DP switch with neon 10 VX1060WH DP switch with neon marked ‘Water Heater’ 10 • BS EN 60669-1• Terminals suitable for 3x2.5mm 2 or 2x4mm 2 conductors • Fitted with knockout position at bottom edge of plate• Cord outlet suitable for flexible cord up to 10mm 2 Dimensions 85mmx85mm with 60.3mm fixing centres Mounting boxes Surface moulded:VX9409Flush metal:SB655 20A DP CONTROL SWITCH MARKING SERVICE The following markings are available as standard by adding theappropriate suffix to the list number, eg VX1060AC: AIR CONDITIONING – ACHEATING – HEHEATER – HTWATER HEATER – WHWASHING MACHINE – WM Markings to customer specification also available 20A BATH/SINK SWITCH LIST NO DESCRIPTION CARTON QTY VX5207 20A bath/sink switch with neon 10 VX5208 20A bath/sink switch 10 • BS 3676 VX1060 VX1060WH VX1060AC VX5207 VX5208 CHIMES AND  BELLPUSHES LIST NO DESCRIPTION CARTON QTY CA1075 2 Note Chime with Integral Transformer 1 CA1076 2 Note Chime 1 CA2001 Bell Push 1 CA2001L Illuminated Bell Push 1 Chime:• 8V ˜ • Max 85 dB/A Dimensions 169mmx104mmx49mm Bellpush:•  Max 24V Dimensions65mmx25mmx20mmFixing screws not supplied CA1075 2009 Volex 76pp  5/9/08  13:38  Page 10

P o w er  & Contr ol 11 45A DP CONTROL SWITCHES LIST NO DESCRIPTION CARTON QTY VX9712 45A DP switch with neon 1 VX9713 45A DP switch 1 VX9702 45A DP switch with neon (large plate) 1 VX9703 45A DP switch (large plate) 1 • BS EN 60669-1• Terminals suitable for up to 1x16mm 2 cable Dimensions 1 gang: 85mmx85mm with 60.3mm fixing centresLarge plate: 85mmx145mm with 120.6mm fixing centres Mounting boxes Surface moulded: 1 gang VX9405; large plate VX9416Flush metal: 1 gang SB618; large plate SB628 • The following markings are available, add the appropriate suffix to the list number, eg VX9712CK – COOKER – CK – SHOWER – SH – AIR CONDITIONING – AC VX9712 VX9713 45A COOKER CONTROL UNITS LIST NO DESCRIPTION CARTON QTY VX9700 45A cooker control unit with 13A switch socket& neon indicators 1 VX9701 45A cooker control unit with 13A switch socket 1 • BS4177, BS1363• Terminals suitable for up to 1x16mm 2 cable • Double pole switching on both 45A & 13A circuits• 2 earth terminals Dimensions 145mmx85mm with 120.6mm fixing centres Mounting boxes Surface moulded:VX9416Flush metal:SB628 VX9702 VX9703 COOKER OUTLET PLATE LIST NO DESCRIPTION CARTON QTY VX9704 Cooker outlet plate with pillar terminals 10 • BS5733 Dimensions 85mmx85mm with 60.3mm fixing centres Mounting boxes Surface moulded:VX9405Flush metal:SB615 VX9700 VX9704 front VX9704 back 2009 Volex 76pp  5/9/08  13:38  Page 11

P o w er  &  Contr ol 13A FLEX OUTLET PLATE LIST NO DESCRIPTION CARTON QTY VX9990 Flex outlet plate with pillar type terminals 10 • BS5733 where applicable• Suitable for flex up to 10mm 2 • Terminals suitable for up to 3x2.5mm 2 conductors Dimensions 85mmx85mm with 60.3mm fixing centres Mounting boxes Surface moulded:VX9409Flush metal:SB655 12 VX9990 VX9990 front back 20A DUAL VOLTAGE SHAVER LIGHT UNIT LIST NO DESCRIPTION CARTON QTY VT7066 115/230V 20VA dual voltage shaver unit 1 • BSEN60598• Socket outlet, with safety shutters• Switching facility to change between 115V and 230V• Pull cord switch for operation of 60W lamp• Accepts British, Continental or American shaver plugs• Automatic cut-out and reset protects against overload Dimensions 438mmx72mm VX9800 DUAL VOLTAGE  SHAVER  UNIT LIST NO DESCRIPTION CARTON QTY VX9800 20VA dual voltage shaver unit 1 • BSEN 61558• Suitable for bathrooms when installed in accordance with IEE regulations • 2 socket outlet, with safety shutters, clearly marked 115V or 230V• Accepts British, Continental or American shaver plugs• Double wound safety isolating transformer with overload protection• Terminal suitable for 2x2.5mm 2 conductors Dimensions 85mmx145mm with 120.6mm fixing centres Mounting boxes Surface moulded:VX9410Flush metal:SB628 VT7066 50A DP CEILING SWITCHES LIST NO DESCRIPTION CARTON QTY VX9706 50A DP ceiling switch with neon andmechanical ‘off’ indicator 5 • BS EN 60669-1• Double pole switching• 60.3mm fixing centres• Pillar terminals suitable for all cables up to 10mm 2 • For ease of wiring, 2 earth terminals are fitted Mounting box Surface moulded:VX9405 VX9706 2009 Volex 76pp  5/9/08  13:38  Page 12

13A PLUGS LIST NO DESCRIPTION CARTON QTY VX1307 White Nylon plug 20 VX1307BK Black Nylon plug 20 • BS1363/A• Fused 13A with ASTA approved BS1362 fuse ROUND PIN PLUGS LIST NO DESCRIPTION CARTON QTY VX1302 2A round pin plug 10 VX0030 5A round pin plug 10 VX0042 15A round pin plug 10 • ASTA approved to BS1363/A or BS546 VX1307 VX1307BK VX1302 VX0030 VX0042 ADAPTORS LIST NO DESCRIPTION CARTON QTY VX1390 13A 3 way fused adaptor 10 VX0580 13A shaver adaptor fused at 1A 10 • BS1363 & BS5733• All pin apertures are spring shuttered• Fused adaptors are fitted with ASTA approved fuses and are designed to allow the fuse to be changed without dismantling • The fused 1A shaver adaptor can be used with British & Continental 2 pin shaver plugs VX0580 VX1390 Accessories 13 BLANKING PLATES LIST NO DESCRIPTION CARTON QTY VX9991 1 gang blanking plate 10 VX9996 2 gang blanking plate 5 • BS5733 where applicable Dimensions 1 gang: 85mmx85mm with 60.3mm fixing centres2 gang: 145mmx85mm with 120.6mm fixing centres VX9991 VX9996 2009 Volex 76pp  5/9/08  13:38  Page 13

The comprehensive Volex Communication range offers a flexible solution to a variety of communication requirements and includes a wide range of coaxial, data and audio modules. 2009 Volex 76pp  5/9/08  13:38  Page 14

Comm unications: TV,T elephone  & Data 15 TELEPHONE OUTLETS LIST NO DESCRIPTION CARTON QTY VX9974 Master 10 VX9984 Secondary 10 Dimensions 86mmx86mm with 60.3mm fixing centres Mounting boxes Surface moulded:VX9404Flush metal: SB655 VX9974 VX9984 RJ11 TELEPHONE  OUTLETS LIST NO DESCRIPTION CARTON QTY VX9986 RJ11 outlet 10 Dimensions 86mmx86mm with 60.3mm fixing centres Mounting boxes Surface moulded:VX9404Flush metal: SB655 VX9986 COAXIAL OUTLETS LIST NO DESCRIPTION CARTON QTY VX9992 1 gang, non-isolated 10 VX9993 2 gang, non-isolated 10 VX9982 1 gang, isolated 10 • BS3041 where applicable Dimensions 85mmx85mm with 60.3mm fixing centres Mounting boxes Surface moulded:VX9409Flush metal: SB655 VX9992 VX9993 2009 Volex 76pp  5/9/08  13:38  Page 15

MOULDED MOUNTING PLATES LIST NO DESCRIPTION CARTON QTY VX9062 2 module mounting plate 10 VX9064 4 module mounting plate 10 Mounting boxesSurface moulded: 1 gang VX9405  2 gang VX9416 Flush metal: 1 gang SB615  2 gang SB625 VX9062 VX9064 VX9062SS VX9064PS RAISED DECORATIVE MOUNTING PLATES 1 Gang  1 Module LIST NO DESCRIPTION CARTON QTY VX9061RBN Black Nickel-Black Insert 1 VX9061RBB Brushed Brass-White Insert 1 VX9061APC Angled polished chrome-Black Insert 1 1 Gang  2 Module LIST NO DESCRIPTION CARTON QTY VX9062SS Stainless Steel-White Insert 1 VX9062PS Polished Steel-White Insert 1 VX9062RBN Black Nickel-Black Insert 1 VX9062RBB Brushed Brass-White Insert 1 VX9062APC Angled polished chrome-Black Insert 1 2 Gang  4 Module LIST NO DESCRIPTION CARTON QTY VX9064SS Stainless Steel-White Insert 1 VX9064PS Polished Steel-White Insert 1 VX3061SS VX3062BN FLATPLATE DECORATIVE MOUNTING PLATES 1 Gang  1 Module LIST NO DESCRIPTION CARTON QTY VX3061SS Stainless Steel-White Insert 1 VX3061PS Polished Steel-White Insert 1 VX3061BN Black Nickel-Black Insert 1 VX3061BB Brushed Brass-White Insert 1 VX3061PBWH Polished Brass-White Insert 1 1 Gang  2 Module LIST NO DESCRIPTION CARTON QTY VX3062SS Stainless Steel-White Insert 1 VX3062PS Polished Steel-White Insert 1 VX3062BN Black Nickel-Black Insert 1 VX3062BB Brushed Brass-White Insert 1 VX3062PBWH Polished Brass-White Insert 1 Comm unications: TV , T elephone & Data 16 VX9062SS fitted with VX9969 VX3061BB fitted with VX9989 2009 Volex 76pp  5/9/08  13:38  Page 16

VX9988 VX9981 VX9980 VX9969 VX9970 VX9989  WHITE DATA & COMMUNICATION MODULES LIST NO DESCRIPTION CARTON QTY VX9969 2 module Quadplexer (1xTV, 1xFM, 2xSky) 10 VX9970 2 module plate 4 binding posts 10 VX9972 1 module plate 2 binding posts VX9973 3 module Multimode (1xTV, 1xFM, 2xSky plus1xFM Return) 10 VX9976  1 module RJ11/12 10 VX9977  2 module Diplexer (1xTV, 1xFM) 10 VX9978  1 Module Single screened TV outlet 10 VX9979  1 module Single non screened TV outlet 10 VX9980 1  module  Telephone  Master 10 VX9981 1  module  Telephone  Secondary 10 VX9987 2 module Triplexer (1xTV, 1xFM, 1xSky) 10 VX9988  1 module RJ45 Outlet - category 5e 10 VX9989  1 module Satellite outlet 10 VX6080  Half module Blank 10 VX6081  One module Blank 10 VX6082  Two module Blank 10 Dimensions 1 module - 25mmx25mm2 module - 25mmx50mm3 module - 25mmx75mm VX9987BK VX9980BK VX9989BK  BLACK DATA & COMMUNICATION MODULES LIST NO DESCRIPTION CARTON QTY VX9976BK  1 module RJ11/12 10 VX9978BK  1 module Single screened TV outlet 10 VX9979BK  1 module Single non screened TV outlet 10 VX9980BK 1  module  Telephone  Master 10 VX9981BK 1  module  Telephone  Secondary 10 VX9987BK 2 module Triplexer (1xTV, 1xFM, 1xSky) 10 VX9988BK  1 module RJ45 Outlet - category 5e 10 VX9989BK  1 module Satellite outlet 10 VX6080BK  Half module Blank 10 VX6081BK  One module Blank 10 Dimensions 1 module - 25mmx25mm2 module - 25mmx50mm Comm unications: TV,T elephone & Data 17 2009 Volex 76pp  4/9/08  03:15  Page 17

Volex offer a complete range of qualityceiling accessories to suit everyinstallation including a range of safetyceiling accessories and a compactfluorescent lampholder which providesthe ideal solution to the energy efficientlighting requirements detailed in theBuilding Regulations. Ceiling Accessories 18 2009 Volex 76pp  4/9/08  03:15  Page 18

STRAIGHT BATTEN LAMPHOLDERS,WITH INTEGRALTERMINAL BLOCK LIST NO DESCRIPTION CARTON QTY VX9215 Heat resistant, 3 terminals & earth, short skirt,T2 rating 10 VX9215HO Heat resistant, 3 terminals & earth, home office skirt, T2 rating 10 • BS EN 61184,T2 Rating• In-line integral terminal block: 3 live, 2 switch, 3 neutral• Each terminal accepts up to 1.5mm 2 cable • Separate earth terminal with 6.0mm 2 capacity • 3 sets of knockouts• Fitted with heat resistant tails VX9215 VX9215HO Ceiling  Accessories 19 PENDANT SETS LIST NO DESCRIPTION CARTON QTY VX6677 Pendant fitting (VX9074 & VX1/T2) 6" HR flex,T2 rating 25 VX6678 Pendant fitting (VX9074 & VX1/T2) 9" HR flex,T2 rating 25 • Ceiling rose manufactured to BS67• Lampholders manufactured to BS5042• Heat resistant, 2 core, 0.75mm 2 PVC flexible cable VX6677 VX6678 LOW ENERGY PENDANT SET LIST NO DESCRIPTION CARTON QTY VX6681 10-13W and 18W 6” Pendant set with compact Fluorescent Lampholder 1 • 42mm diameter Lampshade• Accepts G24 4 pin lamp (not supplied) VX6681 SAFETY PENDANT SET LIST NO DESCRIPTION CARTON QTY VX6850 6” cord (VX9074 & VX0850) 10 • Supplied with appropriate length of heat resistant 0.75mm 2 twin core circular cord to BS 6141 for service loads up to 2.5kg VX6850 SAFETY LAMPHOLDERS LIST NO DESCRIPTION CARTON QTY VX0850 Safety pendant lampholder 20 VX0851 Safety batten lampholder 1 • BS EN 61184 where applicable,T2 rating• Fixed terminals on pendant lampholder accept 1.0m cable• Batten lampholder has terminals for live, neutral, loop in and protective earth • Fixed terminal strip on batten lampholder accepts 1.5m cable• Home Office shield supplied with the safety batten lampholder• ‘Wipe clean’ contacts avoid seizure to pins making for safe and easy lamp replacement VX0850 VX0851 2009 Volex 76pp  4/9/08  03:15  Page 19

PENDANT LAMPHOLDERS LIST NO DESCRIPTION CARTON QTY VX1/T2 Cord grip lampholder, heat resistant, short skirt,spring plungers,T2 rating 20 VX1/T2HO Cord grip lampholder, heat resistant,home office skirt, spring plungers,T2 rating 10 VX4522 1 / 2 ” screwed entry double pole switched lampholder 20 • BS EN 61184,T2 Rating• All unswitched lampholders have one-piece thermoplastic con- struction of interior • Switched lampholder has metal interior• Non-rising terminals, ensuring that cables are not disturbed when the lamp is changed • Non-stick skirt and cap VX1/T2 VX1/T2HO CEILING ROSES LIST NO DESCRIPTION CARTON QTY VX9074 3 terminals & earth 10 • BS67• In-line integral terminal block: 3 live, 2 switch, 3 neutral• Each terminal accepts up to 1.5mm 2 cable • Separate earth terminal with 6.0mm 2 capacity • 3 sets of knockouts• 3 fixing holes at 50.8mm centres VX9074 Ceiling  Accessories 20 STRAIGHT BATTEN LAMPHOLDERS LIST NO DESCRIPTION CARTON QTY VX0205 Heat resistant, 3 terminals, short skirt,T2 rating 10 VX0205HO Heat resistant, 3 terminals, home office skirt,T2 rating 10 • BS EN 61184,T2 Rating• Direct wiring to lampholder for VX0205 series• 50.8mm fixing centres VX0205 VX0205HO VX0208HO VX0218HO ANGLED BATTEN LAMPHOLDERS LIST NO DESCRIPTION CARTON QTY VX0208HO Heat resistant, 3 terminals, home office skirt, T2 rating 10 VX0218HO Heat resistant, 3 terminals & earth, home office skirt, T2 rating 10 • BS EN 61184,T2 Rating• VX0208HO – Direct wiring to lampholder• VX0218HO – Separate 4 way terminal block with lampholder VX0208HO – tails and integral backplate • 50.8mm fixing centres 2009 Volex 76pp  4/9/08  03:15  Page 20

6A CEILING SWITCHES LIST NO DESCRIPTION CARTON QTY VX9001 1 way, 6A ceiling switch 10 VX9002 2 way, 6A ceiling switch 10 • BS EN 60669-1• Supplied with pull cord• 50.8mm fixing centres VX9001 50A DP CEILING SWITCH LIST NO DESCRIPTION CARTON QTY VX9706 DP ceiling switch with neon & mechanical‘off’ indicator 5 • BS EN 60669-1• Terminal suitable for all cables up to 10mm 2 • 60.3mm fixing centres• Pillar terminals suitable for all cables up to 10mm 2 • For ease of wiring, 2 earth terminals are fitted Mounting boxes For use with surface box VX9405 VX9706 Ceiling  Accessories 21 JUNCTION BOXES LIST NO DESCRIPTION CARTON QTY VX9023BK 30A, 3 terminals, black 10 VX9023 30A, 3 terminals, white 10 VX9029BK 20A, 4 terminals, black 10 VX9029 20A, 4 terminals, white 10 • BS6220• The selective entry shutters on the cover close any entry slots not in use • Symbols clearly show which entries are open and closed• Slotted pillar terminals accept up to 4x4mm 2 (30A) or 4x1.5mm 2 (20A) twin & earth cables VX9029 VX9023BK VX20/2 MOUNTING BLOCKS LIST NO DESCRIPTION CARTON QTY VX20/2 2 terminal 20 VX0009 VX0010 VX0011 ANCILLARY ITEMS LIST NO DESCRIPTION CARTON QTY VX0009 Shade ring 100 VX0010 Short skirt 50 VX0011 Home office skirt 50 VX0018 Break ring 50 2009 Volex 76pp  4/9/08  03:15  Page 21

A comprehensive range of PVC andUrea surface mounted boxes areavailable for Volex accessories. This unique Volex conversion unit provides asimple method of converting a single flushmounted accessory into a slim surface mounted3 gang unit. Installation Bo x es 22 2009 Volex 76pp  4/9/08  03:15  Page 22

Installation  Bo x es 23 SURFACE MOUNTING BOXES 1 Gang  LIST NO DESCRIPTION CARTON QTY VX9401 1 gang architrave moulded, 19mm deep 10 VX9404 1 gang moulded, 20mm deep with earth terminal 10 VX9409 1 gang moulded, 29mm deep 10 VX9405 1 gang moulded, 42mm deep 10 • BS5733 SURFACE MOUNTING BOXES 2 Gang  LIST NO DESCRIPTION CARTON QTY VX9402 2 gang architrave moulded, 19mm deep 10 VX9412 2 gang moulded, 20mm deep with earth terminal 10 VX9414 2 gang moulded, 29mm deep 5 VX9415 2 gang moulded dual, 29mm deep 5 VX9417 2 gang moulded, 32mm deep 5 VX9416 2 gang moulded, 35mm deep with cable clamp 10 VX9410 2 gang moulded, 47mm deep with cable clamp 5 • BS5733 VX9409 VX9414 SURFACE MOUNTING BOXES 3 Gang  LIST NO DESCRIPTION CARTON QTY VX9403 3 gang moulded, 29mm deep 5 • BS5733 VX9403 CONVERSION PATTRESSES LIST NO DESCRIPTION CARTON QTY VX9406 2 gang socket conversion pattress, 20mm deep 5 VX9143 3 gang socket conversion pattress, 20mm deep 5 • This unique range provides the ideal method to convert a flush mounted 1 gang socket to a slim surface mounted 2 or 3 gangversion VX9406 2009 Volex 76pp  4/9/08  03:15  Page 23

2009 Volex 76pp  4/9/08  03:15  Page 24

Grid System 25 The Volex grid switch system enhances an alreadycomprehensive range of electrical accessories.Offering versatility and style,Volex grid is available in a choiceof finishes that can be flush or surface mounted.Switches have silver alloy contacts for prolonged life andlow contact resistance and are designed to minimise arc flashand prevent front access to live parts. 2009 Volex 76pp  4/9/08  03:15  Page 25

Grid System 26 10AX SWITCHES - MOULDED ROCKER LIST NO DESCRIPTION CARTON QTY VG3430 10AX 1 way SP 6 VG3530 10AX 2 way SP 6 VG3489 10AX Retractive 6 VG3490 10AX Retractive - bell symbol 6 VG3490/1  10AX Retractive - fan symbol 6 • BS EN 60669-1• Fully rated for fluorescent and inductive loads.• Retractive switches can be wired for normally open (N/O) or normally closed (N/C) circuits. 20AX SWITCHES - MOULDED ROCKER LIST NO DESCRIPTION CARTON QTY VG3450 1 way 6 VG3451  1 way complete with key 6 VG3460 DP 6 VG3461 DP complete with key 6 VG3461ELT DP complete with key marked ‘Emergency light test’ 6 VG3469 DP marked ‘ON’ 6 VG3535 Intermediate 6 VG3550 2 way 6 VG3551 2 way complete with key 6 VG3552 2 way and off 6 VG3940 Spare key 6 • BS EN 60669-1 • Fully rated for fluorescent and inductive loads (except List No.VG3552). ANCILLARY ITEMS - MOULDED  LIST NO DESCRIPTION CARTON QTY VG3435 Cord outlet - 10mm diameter aperture, complete with earthing terminal and cable clamp 6 VG3436 Fuse unit fitted with 13A ASTA certified fuse link 6 VG3491 Indicator - Red 6 VG3492 Blanking  component 6 VG3493 Indicator - Green 6 VG3494 Indicator - Amber 6 • BS 5733 (Where Applicable) VG3430 VG3490 VG3490/1 VG3450 VG3535 VG3551 VG3460 VG3550 VG3435 VG3491 VG3493 VG3436 VG3492 VG3494 LIST NO MARKING CARTON QTY LIST NO MARKING CARTON QTY VG3460BO BOILER 6 VG3460HT HEATING SYSTEM 6 VG3460HD COOKER HOOD 6 VG3460MW MICROWAVE 6 VG3460DW DISHWASHER 6 VG3460TD TUMBLE DRYER 6 VG3460EF EXTRACTOR FAN 6 VG3460WD WASTE DISPOSAL 6 VG3460FR FRIDGE 6 VG3460WDR WASHER DRYER 6 VG3460FZ FREEZER 6 VG3460WM WASHING MACHINE 6 VG3460FF FRIDGE FREEZER 6 VG3460WA WATER HEATER 6 VG3460HB HOB 6 Marking to customer specification also available 20AX DOUBLE POLE SWITCH MARKINGS VG3901 VG3904 GRIDS COMPLETE WITH EARTH TERMINAL LIST NO DESCRIPTION CARTON QTY VG3901 1 gang 20 VG3902 2  gang 20 VG3903 3  gang 10 VG3904 4  gang 10 Dimensions 1-2 gang 81mmx58mm 3-4 gang 141mmx58mm When required for surface mounting assemblies, the fixing earsshould be removed or bent downwards at 90˚. 2009 Volex 76pp  4/9/08  03:15  Page 26

Grid System 27 VG3572 VG3570WH VG3574PS VG3578SS VG3201SG VG3206SG FLUSH WHITE  PLATES LIST NO DESCRIPTION CARTON QTY VG3571 1 gang white moulded 20 VG3572 2 gang white moulded 20 VG3573 3 gang white moulded 10 VG3574 4 gang white moulded 10 VG3576 6 gang white moulded 1 VG3578WH 8 gang white metal 1 VG3570WH 12 gang white metal 1 Dimensions 1-2 gang 86mmx86mm 6-8 gang 147mmx147mm 3-4 gang 146mmx86mm 12 gang 147mmx207mm FLUSH METAL PLATES LIST NO DESCRIPTION CARTON QTY VG3571 _ _ 1 gang 20 VG3572 _ _ 2 gang 20 VG3573 _ _ 3 gang 20 VG3574 _ _ 4 gang 20 VG3576 _ _ 6 gang 1 VG3578 _ _ 8 gang 1 VG3579 _ _ 9 gang 1 VG3570 _ _ 12 gang 1 Dimensions 1-2 gang 86mmx86mm  6-8 gang 147mmx147mm 3-4 gang 146mmx86mm  9-12 gang 147mmx207mmadd suffix P PS S (Polished Steel) S SS S (Stainless Steel)  BOXES LIST NO DESCRIPTION CARTON QTY VG3201SG 1 and 2 gang surface or flush 10 VG3203SG 3 and 4 gang surface or flush 5 VG3206SG 6 and 8 gang surface or flush 1 VG3209SG 12 gang surface or flush 1 Dimensions 1-2 gang 73mmx73x40mm  3-4 gang 133mmx73mmx40mm 6-8 gang 133mmx133mmx40mm 12 gang 133mmx194mmx40mm 20mm knock-outs in 1 and 2 gang box.20mm and 25mm knock-outs in 3-12 gang boxes. VG3583SG VG3586SG SURFACE METALCLAD PLATES LIST NO DESCRIPTION CARTON QTY VG3581SG 1 gang 20 VG3582SG 2 gang 20 VG3583SG 3 gang 10 VG3584SG 4 gang 10 VG3586SG 6 gang 1 VG3588SG 8 gang 1 Dimensions 1-2 gang 77mmx77mm3-4 gang 137mmx77mm6-8 gang 137mmx137mm 2009 Volex 76pp  4/9/08  03:15  Page 27

Available in Brushed Steel, Polished Steel, Black Nickel, Brushed Brass and Satin Brass finishes, the Volex metal plate range allows specification of a co-ordinated and comprehensive range of  wiring accessories. Metal Plate 28 Stainless Steel Curved Edge Polished Stainless Steel Curved Edge Satin Brass Curved Edge Black Nickel Round Edge Brushed Brass Round Edge Polished Chrome Angled Edge Satin Bras Curved Ed 2009 Volex 76pp  4/9/08  03:15  Page 28

10AX SWITCHES LIST NO DESCRIPTION CARTON QTY VX1010 _ _ 1 gang 1 way switch 10 VX1020 _ _ 1 gang 2 way switch 10 VX1030 _ _ 1 gang intermediate switch 10 VX1040 _ _ 2 gang 2 way switch 10 VX1050 _ _ 3 gang 2 way switch 10 VX1054 _ _ 4 gang 2 way switch 5 • BS EN 60669-1• Terminals suitable for 4x1.0mm 2 , 3x1.5mm 2 or 1x2.5mm 2 conductors • Fully rated at 10AX for fluorescent loads VX1040PS VX1050SS 10AX TOGGLE  SWITCHES LIST NO DESCRIPTION CARTON QTY VX1120_ _ 1 gang 1 way 1 VX1140_ _ 2 gang 2 way 1 VX1150_ _ 3 gang 2 way 1 VX1130_ _ Intermediate 1 VX1120RBN VX1140RBB DIMMERS LIST NO DESCRIPTION CARTON QTY VX0250_ _PU 1 gang 250W Dimmer 5 VX0252_ _PU 2 gang 250W Dimmer 5 VX0400_ _PU 1 gang 400W Dimmer 5 VX0402_ _PU 2 gang 400W Dimmer 5 VX0253_ _PU 3 gang 250W Dimmer 1 VX0254_ _PU 4 gang 250W Dimmer 1 VX0400LV_ _ 1 gang 400W Low Voltage Dimmer 1 VX0252LV_ _ 2 gang 250W Low Voltage Dimmer 1 VX0253LV_ _ 3 gang 250W Low Voltage Dimmer 1 VX0500TD_ _ 500W Touch Dimmer 1 VX0400TRD_ _ 400W Touch/Remote  Dimmer 1 VX0402SSPU VX0253APCPU FAN ISOLATOR LIST NO DESCRIPTION CARTON QTY VX1013 _ _ Triple Pole Fan Isolator 10 • BS EN 60669-1, BS EN 60947-3• Terminals suitable for 4x1.0mm 2 , 3x1.5mm 2  or 1x2.5mm 2 conductors 20A DP SWITCHES LIST NO DESCRIPTION CARTON QTY VX1060 _ _ Switch with neon 10 VX1060F _ _ Switch with neon, flex outlet & cord grip 10 VX1060WH _ _ Switch with neon, marked ‘Water Heater’ 10 VX1060WHF _ _  Switch with neon, flex outlet & cord grip, marked ‘Water Heater’ 10 VX1070 _ _ Switch 10 VX1070F _ _ Switch with flex outlet & cord grip 10 • BS EN 60669-1• Terminals suitable for 3x2.5mm 2 or 2x4.0mm 2 conductors VX1060SB VX1060FSS VX1013SS Metal  Plate 29 Metal plate accessories are available in the following finishes: SS - Brushed Stainless Steel; SB - Satin Brass; PS - Polished Stainless SteelAPC - Angled Polished Chrome; RBB - Round Edge Brushed Brass; RBN - Round Edge Black Nickel. Indicate the finish you require byadding the suffix to the list number, eg VX1080SS   Only available in Black Nickel, Brushed Brass and Polished Chrome  Only available in Stainless Steel and Polished Steel Satin Brass Curved Edge Technical detail - page 66 2009 Volex 76pp  4/9/08  03:15  Page 29

13A SOCKET OUTLETS LIST NO DESCRIPTION CARTON QTY VX9100 _ _  1 gang unswitched socket 10 VX9200 _ _  2 gang unswitched socket 5 VX1300 _ _  1 gang SP switched socket 10 VX1300/D _ 1 gang DP switched socket 10 VX1500 _ _  2 gang SP switched socket 5 VX1500/D _ 2 gang DP switched socket 5 VX1400 _ _  1 gang SP switched socket with neon 10 VX1600 _ _  2 gang SP switched socket with neon 5 • BS1363• Terminals suitable for up to 3x2.5mm 2 or 2x4.0mm 2 conductors • 2 gang DP sockets come with twin earth as standard 45A COOKER CONTROL UNIT LIST NO DESCRIPTION CARTON QTY VX9701 _ _  Cooker Control Unit 1 VX9700 _ _ Cooker Control Unit with neon 1 • BS4177, BS1363• Terminals suitable for up to 1x16mm 2 conductors VX9701PS ROUND PIN SOCKET OUTLETS LIST NO DESCRIPTION CARTON QTY VX9900 _ _  15A switched socket, 1 gang, SP 10 VX9905 _ _ 5A switched socket, 1 gang, SP 10 VX9901 _ _  2A 3 pin socket 10 • BS546 VX9905RBN 13A FUSED CONNECTION UNITS LIST NO DESCRIPTION CARTON QTY VX1080 _ _ DP switched 10 VX1080F _ _  DP switched with flex outlet & cord grip 10 VX1081 _ _ DP switched with neon 10 VX1081F _ _  DP switched with neon, flex outlet & cord grip 10 VX1090 _ _ Unswitched 10 VX1090F _ _  Unswitched with flex outlet & cord grip 10 • BS1363• Terminals suitable for 3x2.5mm 2 or 2x4.0mm 2 conductor VX1080SB VX1081RBN VX1300APC VX1500SS Metal Plate 30 45A DP CONTROL SWITCHES LIST NO DESCRIPTION CARTON QTY VX9712 _ _ 1 gang 45A DP Switch with neon  1 VX9713 _ _ 1 gang 45A DP Switch  1 VX9702 _ _ 2 gang 45A DP Switch with neon  1 VX9703 _ _ 2 gang 45A DP Switch 1 VX9713PS VX9703SS Metal plate accessories are available in the following finishes: SS - Brushed Stainless Steel; SB - Satin Brass; PS - Polished Stainless SteelAPC - Angled Polished Chrome; RBB - Round Edge Brushed Brass; RBN - Round Edge Black Nickel. Indicate the finish you require byadding the suffix to the list number, eg VX1080SS   Only available in Black Nickel, Brushed Brass and Polished Chrome  Only available in Stainless Steel and Polished Steel Technical detail - page 66 2009 Volex 76pp  4/9/08  03:15  Page 30

TELEPHONE OUTLETS LIST NO DESCRIPTION CARTON QTY VX9974 _ _ Telephone master socket 10 VX9984 _ _ Telephone secondary socket 10 VX9974SB COAXIAL OUTLETS LIST NO DESCRIPTION CARTON QTY VX9992 _ _ 1 gang, non-isolated 10 VX9993 _ _ 2 gang, non-isolated 10 VX9992PS VX9993SB MOUNTING PLATES LIST NO DESCRIPTION CARTON QTY VX9061 _ _  1 module mounting plate 1 VX9062 _ _ 2 module mounting plate 5 VX9064 _ _  4 module mounting plate 5 • Refer to page 17 for compatible modules VX9062RBB VX9064SS BLANKING PLATES LIST NO DESCRIPTION CARTON QTY VX9991 _ _ 1 gang 10 VX9996 _ _ 2 gang 5 VX9991PS VX9996SB SHAVER SOCKET LIST NO DESCRIPTION CARTON QTY VX9800 _ _ Dual Voltage Shaver Unit 1 • BSEN61558• Terminals suitable for up to 2x2.5mm 2 conductors VX9800PS Metal  Plate 31 Metal plate accessories are available in the following finishes: SS - Brushed Stainless Steel; SB - Satin Brass; PS - Polished Stainless SteelAPC - Angled Polished Chrome; RBB - Round Edge Brushed Brass; RBN - Round Edge Black Nickel. Indicate the finish you require byadding the suffix to the list number, eg VX1080SS   Only available in Black Nickel, Brushed Brass and Polished Chrome  Only available in Stainless Steel and Polished Steel Technical detail - page 66 2009 Volex 76pp  4/9/08  03:15  Page 31

Metal  Plate 32 10AX SWITCHES 1G 1 Way Switch 10A   VX1010PS VX1010SS VX1010SB 1G 2 Way Switch 10A    VX1020PS VX1020SS VX1020SB 2G 2 Way Switch 10A  VX1040PS VX1040SS VX1040SB 3G 2 Way Switch 10A  VX1050PS VX1050SS VX1050SB 4G 2 Way Switch 10A  VX1054PS VX1054SS VX1054SB Intermediate Switch    VX1030PS VX1030SS VX1030SB Fan Isolating Switch    VX1013PS VX1013SS VX1013SB TOGGLE SWITCHES 1G 2 Way Toggle Switch  -  -  -  2G 2 Way Toggle Switch  -  -  -  3G 2 Way Toggle Switch  -  -  -  Intermediate Toggle Switch  -  -  - DIMMERS Dimmer 2 Way Mains / LV 1x400W / 400VA  -  -  -  Dimmer 2 Way Mains / LV 2x250W / 250VA  -  -  -  Dimmer 2 Way Mains / LV 3x250W / 250VA  -  -  -  1G Dimmer 2 Way Mains 1X250W  VX0250PSPU VX0250SSPU VX0250SBPU 1G Dimmer 2 Way Mains 1X400W  VX0400PSPU VX0400SSPU VX0400SBPU 2G Dimmer 2 Way Mains 2X250W  VX0252PSPU VX0252SSPU VX0252SBPU 3G Dimmer 2 Way Mains 3X250W  -  -  -  4G Dimmer 2 Way Mains 4X250W  -  -  -  Touch Dimmer 1 Way 1X500W / 500VA  -  -  -  Touch / Remote Dimmer 1 Way 1X400W -  -  -  SOCKET OUTLETS 13A 1G Switched Socket Outlet SP  VX1300PS VX1300SS VX1300SB 13A 2G Switched Socket Outlet SP  VX1500PS VX1500SS VX1500SB 13A 1G Switched Socket Outlet DP  VX1300PS/D VX1300SS/D VX1300SB/D 13A 2G Switched Socket Outlet DP  VX1500PS/D VX1500SS/D VX1500SB/D 5A Switched Socket Outlet SP  VX9905PS VX9905SS  -  FUSED CONNECTION UNITS Unswitched Fused Connection Unit 13A   VX1090PS VX1090SS VX1090SB Switched Fused Connection Unit 13A   VX1080PS VX1080SS VX1080SB Switched Fused Connection Unit 13A & Neon   VX1081PS VX1081SS VX1081SB CONTROL SWITCHES 1G DP 20A Switch      VX1070PS VX1070SS VX1070SB 1G DP 20A Switch With Neon      VX1060PS VX1060SS VX1060SB Cooker Switch 1G Plate 45A   VX9713PS VX9713SS VX9713SB Cooker Switch 2G Plate 45A   VX9703PS VX9703SS VX9703SB Cooker Control Unit + Neon & 13A Socket 45A    VX9700PS VX9700SS VX9700SB Shaver Dual Voltage 230V/115V  VX9800PS VX9800SS VX9800SB DATA & COMMUNICATIONS Telephone Master Socket    VX9974PS VX9974SS VX9974SB Telephone Secondary Socket   VX9984PS VX9984SS VX9984SB Co-Axial TV Socket  VX9992PS VX9992SS VX9992SB Twin TV Co-Axial Socket  VX9993PS VX9993SS VX9993SB 1 gang 1 Module Communication Plate  -  -  -  1 gang 2 Module Communication Plate  VX9062PS VX9062SS VX9062SB 2 gang 4 Module Communication Plate  VX9064PS VX9064SS VX9064SB Blanking Plate 1 Gang  VX9991PS VX9991SS VX9991SB Blanking Plate 2 Gang  VX9996PS VX9996SS VX9996SB Note: PS, SS and SB Products are available with Black Inserts - Add BK to the List Number ie: VX1020SSBK. Some Black insert Products may be made to order Polished Steel  Stainless Steel Satin Brass White Insert White Insert White Insert STANDARD RAISED 2009 Volex 76pp  4/9/08  03:15  Page 32

Metal Plate 33 - -  -  VX1020RBN VX1020RBB VX1020APC VX1040RBN VX1040RBB VX1040APC VX1050RBN VX1050RBB VX1050APC VX1054RBN VX1054RBB VX1054APC VX1030RBN VX1030RBB VX1030APC VX1013RBN VX1013RBB VX1013APC VX1120RBN VX1120RBB VX1120APC VX1140RBN VX1140RBB VX1140APC VX1150RBN VX1150RBB VX1150APC VX1130RBN VX1130RBB VX1130APC VX0400LVRBN VX0400LVRBB VX0400LVAPC VX0252LVRBN VX0252LVRBB VX0252LVAPC VX0253LVRBN VX0253LVRBB VX0253LVAPC - -  - VX0400RBNPU VX0400RBBPU VX0400APCPU VX0252RBNPU VX0252RBBPU VX0252APCPU VX0253RBNPU VX0253RBBPU VX0253APCPU VX0254RBNPU VX0254RBBPU VX0254APCPU VX0500TDRBN VX0500TDRBB VX0500TDAPC VX0400TRDRBN VX0400TRDRBB VX0400TRDAPC - - - - - -  VX1300RBN/D VX1300RBB/D VX1300APC/D VX1500RBN/D VX1500RBB/D VX1500APC/D VX9905RBN VX9905RBB VX9905APC VX1090RBN VX1090RBB VX1090APC VX1080RBN VX1080RBB VX1080APC VX1081RBN VX1081RBB VX1081APC - - - VX1060RBN VX1060RBB VX1060APC VX9712RBN VX9712RBB VX9712APC VX9703RBN VX9703RBB VX9703APC VX9700RBN VX9700RBB VX9700APC VX9800RBN VX9800RBB VX9800APC VX9974RBN VX9974RBB VX9974APC VX9984RBN VX9984RBB VX9984APC VX9992RBN VX9992RBB VX9992APC VX9993RBN VX9993RBB VX9993APC VX9061RBBN VX9061RBB VX9061APC VX9062RBBN VX9062RBB VX9062APC - -  -  VX9991RBN VX9991RBB VX9991APC VX9996RBN VX9996RBB VX9996APC  Black Nickel Brushed Brass  Polished Chrome Black Insert White Insert Black Insert ROUND EDGE ANGLED EDGE 2009 Volex 76pp  4/9/08  03:15  Page 33

Flat Plate 34 The Volex Flatplate range of metal plateaccessories offers a clean and slim solution witha decorative finish for residential dwellings.Products are available in Polished Chrome,Stainless Steel, Black Nickel, Brushed Brassand Polished Brass plates with a choice of white or black inserts on certain finishes. Polished Chrome Stainless Steel Black Nickel Brushed Brass Polished Brass 2009 Volex 76pp  4/9/08  03:16  Page 34

10AX SWITCHES LIST NO DESCRIPTION CARTON QTY VX3010 _ _ 1 gang 1 way switch 1 VX3020 _ _ 1 gang 2 way switch 1 VX3030 _ _ 1 gang intermediate switch 1 VX3040 _ _ 2 gang 2 way switch 1 VX3050 _ _ 3 gang 2 way switch 1 VX3054 _ _ 4 gang 2 way switch 1 • BS EN 60669-1• Terminals suitable for 4x1.0mm 2 or 3x1.5mm 2  conductors VX3020PSBK VX3054BB SWITCHED SOCKETS LIST NO DESCRIPTION CARTON QTY VX3300 _ _/D 1 gang DP Switched Socket 1 VX3500 _ _/D 2 gang DP Switched Socket 1 VX3905 _ _ 5A Switched Socket 1 • BS 1363• Terminals suitable for up to 3x2.5mm 2 or 2x4.0mm 2  conductors 13A FUSED CONNECTION UNITS LIST NO DESCRIPTION CARTON QTY VX3080 _ _ DP switched 1 VX3081 _ _ DP switched with neon  1 VX3090 _ _ Unswitched 1 • BS 1363• Terminals suitable for up to 3x2.5mm 2 or 2x4.0mm 2  conductors VX3080PB VX3081PS VX3300PS / D VX3500SS / D Flat Plate 35 Flush back boxes must be at least 5mm below the surface of the wall.SS - Brushed Stainless Steel - White interior as standard (add BK suffix for Black) ie:VX3080SSBKPS - Polished Chrome - White interior as standard (add BK suffix for Black) ie:VX3080PSBKPB - Polished Brass - Black interior as standard (add WH suffix for White) ie:VX3080PBWHBN - Black Nickel - Black interior as standardBB - Brushed Brass - White interior as standardIndicate the finish required by adding the suffix to the List Number ie:VX3500SS/D TOGGLE SWITCHES LIST NO DESCRIPTION CARTON QTY VX3120_ _ 1 gang 2 way 1 VX3140_ _ 2 gang 2 way 1 VX3150_ _ 3 gang 2 way 1 VX3130_ _ Intermediate 1 • BS EN 60669-1 VX3120BN VX3140BB DIMMERS LIST NO DESCRIPTION CARTON QTY VX3252_ _PU 2 gang 250W Dimmer 1 VX3400_ _PU 1 gang 400W Dimmer 1 VX3253_ _PU 3 gang 250W Dimmer 1 VX3254_ _PU 4 gang 250W Dimmer 1 VX3400LV_ _ 1 gang 400W Low Voltage Dimmer 1 VX3252LV_ _ 2 gang 250W Low Voltage Dimmer 1 VX3253LV_ _ 3 gang 250W Low Voltage Dimmer 1 VX3005TDBN  Touch Dimmer 500W 1 VX3400TRDBN Touch/RemoteDimmer  400W 1 VX3252PBPU VX3005TDBB Technical detail - page 66 2009 Volex 76pp  4/9/08  03:16  Page 35

20A SWITCH LIST NO DESCRIPTION CARTON QTY VX3060 _ _ 1 gang Switch with neon 1 • BS EN 60669-1• Terminals suitable for 3x2.5mm 2  or 2x4.0mm 2  conductors VX3060SS 45A SWITCH LIST NO DESCRIPTION CARTON QTY VX3712 _ _ 1 gang Switch with neon 1 VX3703 _ _ 2 gang Switch 1 • BS EN 60669-1• Terminals suitable for up to 1x16mm 2  conductor 45A COOKER CONTROL SWITCH LIST NO DESCRIPTION CARTON QTY VX3700 _ _ Cooker Switch with neon 1 • BS 4177, BS 1363• Terminals suitable for up to 1x16mm 2  conductor VX3712BN VX3700PB Flat Plate 36 6AX ISOLATOR LIST NO DESCRIPTION CARTON QTY VX3013 _ _ TP Fan Isolator 1 • BS EN 60669-1, BS EN 60947-3• Terminals suitable for 4x1.0mm 2 or 3x1.5mm 2  conductors VX3013PS Flush back boxes must be at least 5mm below the surface of the wall.SS - Brushed Stainless Steel - White interior as standard (add BK suffix for Black) ie:VX3080SSBKPS - Polished Chrome - White interior as standard (add BK suffix for Black) ie:VX3080PSBKPB - Polished Brass - Black interior as standard (add WH suffix for White) ie:VX3080PBWHBN - Black Nickel - Black interior as standardBB - Brushed Brass - White interior as standardIndicate the finish required by adding the suffix to the List Number ie:VX3500SS/D Technical detail - page 66 2009 Volex 76pp  4/9/08  03:16  Page 36

TELEPHONE OUTLETS LIST NO DESCRIPTION CARTON QTY VX3974 _ _ Telephone Master 1 VX3984 _ _ Telephone Secondary 1 VX3974PB COAXIAL OUTLET LIST NO DESCRIPTION CARTON QTY VX3992 _ _ 1 gang non isolated 1 VX3993 _ _ 2 gang non isolated 1 • BS 3041 where applicable VX39992PS COMMUNICATION MOUNTING PLATE LIST NO DESCRIPTION CARTON QTY VX3061 _ _ 1 gang 1 module mounting plate 1 VX3062 _ _ 2 gang 2 module mounting plate 1 Refer to page 17 for compatible modules  VX3061BB BLANKING PLATES LIST NO DESCRIPTION CARTON QTY VX3991 _ _ 1 gang blank plate 1 VX3996 _ _ 2 gang blank plate 1 VX3991PS SHAVER SOCKET LIST NO DESCRIPTION CARTON QTY VX3800 _ _ Dual Voltage Shaver Socket 1 • BSEN 61558• Terminals suitable 2x2.5mm 2  conductors VX3800SS Flat Plate 37 Flush back boxes must be at least 5mm below the surface of the wall.SS - Brushed Stainless Steel - White interior as standard (add BK suffix for Black) ie:VX3080SSBKPS - Polished Chrome - White interior as standard (add BK suffix for Black) ie:VX3080PSBKPB - Polished Brass - Black interior as standard (add WH suffix for White) ie:VX3080PBWHBN - Black Nickel - Black interior as standardBB - Brushed Brass - White interior as standardIndicate the finish required by adding the suffix to the List Number ie:VX3500SS/D Technical detail - page 66 2009 Volex 76pp  4/9/08  03:16  Page 37

Flat Plate 38 10AX SWITCHES 1G 1 Way Switch 10A   1G 2 Way Switch 10A    VX3020PS VX3020SS 2G 2 Way Switch 10A  VX3040PS VX3040SS 3G 2 Way Switch 10A  VX3050PS VX3050SS 4G 2 Way Switch 10A  VX3054PS VX3054SS Intermediate Switch    VX3030PS VX3030SS Fan Isolating Switch    VX3013PS VX3013SS TOGGLE SWITCHES 1G 2 Way Toggle Switch  VX3120PS VX3120SS 2G 2 Way Toggle Switch  VX3140PS VX3140SS 3G 2 Way Toggle Switch  VX3150PS VX3150SS Intermediate Toggle Switch  VX3130PS VX3130SS DIMMERS Dimmer 2 Way Mains / LV 1x400W / 400VA  VX3400LVPS VX3400LVSS Dimmer 2 Way Mains / LV 2x250W / 250VA  VX3252LVPS VX3252LVSS Dimmer 2 Way Mains / LV 3x250W / 250VA  VX3253LVPS VX3253LVSS 1G Dimmer 2 Way Mains 1X400W  VX3400PSPU VX3400SSPU 2G Dimmer 2 Way Mains 2X250W  VX3252PSPU VX3252SSPU 3G Dimmer 2 Way Mains 3X250W  VX3253PSPU VX3253SSPU 4G Dimmer 2 Way Mains 4X250W  VX3254PSPU VX3254SSPU Touch Dimmer 1 Way 1X500W / 500VA  VX3005TDPS VX3005TDSS Touch / Remote Dimmer 1 Way 1X400W VX3400TRDPS VX3400TRDSS SOCKET OUTLETS 13A 1G Switched Socket Outlet DP  VX3300PS/D VX3300SS/D 13A 2G Switched Socket Outlet DP  VX3500PS/D VX3500SS/D 5A Switched Socket Outlet SP  VX3905PS VX3905SS FUSED CONNECTION UNITS Unswitched Fused Connection Unit 13A   VX3090PS VX3090SS Switched Fused Connection Unit 13A   VX3080PS VX3080SS Switched Fused Connection Unit 13A & Neon   VX3081PS VX3081SS CONTROL SWITCHES 1G DP 20A Switch With Neon      VX3060PS VX3060SS Cooker Switch 1G Plate 45A   VX3713PS VX3713SS Cooker Switch 2G Plate 45A   VX3703PS VX3703SS Cooker Control Unit with Neon & 13A Socket 45A    VX3700PS VX3700SS Shaver Dual Voltage 230V/115V  VX3800PS VX3800SS DATA & COMMUNICATIONS Telephone Master Socket    VX3974PS VX3974SS Telephone Secondary Socket   VX3984PS VX3984SS Co-Axial TV Socket  VX3992PS VX3992SS Twin TV Co-Axial Socket  VX3993PS VX3993SS 1 gang 1 Module Communication Plate  VX3061PS VX3061SS 1 gang 2 Module Communication Plate  VX3062PS  VX3062SS Blanking Plate 1 Gang  VX3991PS VX3991SS Blanking Plate 2 Gang  VX3996PS VX3996SS Note: Polished Chrome and Stainless Steel Products are available with Black Inserts - Add BK to the List Number ie: VX3020SSBK. Polished Chrome Brushed Steel White Insert White Insert F 2009 Volex 76pp  4/9/08  03:16  Page 38

Flat Plate 39 VX3020BN VX3020BB VX3020PB VX3040BN VX3040BB VX3040PB VX3050BN VX3050BB VX3050PB VX3054BN VX3054BB VX3054PB VX3030BN VX3030BB VX3030PB VX3013BN VX3013BB VX3013PB VX3120BN VX3120BB VX3120PB VX3140BN VX3140BB VX3140PB VX3150BN VX3150BB VX3150PB VX3130BN VX3130BB VX3130PB VX3400LVBN VX3400LVBB VX3400LVPB VX3252LVBN VX3252LVBB VX3252LVPB VX3253LVBN VX3253LVBB VX3253LVPB VX3400BNPU VX3400BBPU VX3400PBPU VX3252BNPU VX3252BBPU VX3252PBPU VX3253BNPU VX3253BBPU VX3253PBPU VX3254BNPU VX3254BBPU VX3254PBPU VX3005TDBN VX3005TDBB VX3005TDPB VX3400TRDBN VX3400TRDBB VX3400TRDPB VX3300BN/D VX3300BB/D VX3300PB/D VX3500BN/D VX3500BB/D VX3500PB/D VX3905BN VX3905BB VX3905PB    VX3090BN VX3090BB VX3090PB VX3080BN VX3080BB VX3080PB VX3081BN VX3081BB VX3081PB VX3060BN VX3060BB VX3060PB VX3713BN VX3713BB VX3713PB VX3703BN VX3703BB VX3703PB VX3700BN VX3700BB VX3700PB VX3800BN VX3800BB VX3800PB VX3974BN VX3974BB VX3974PB VX3984BN VX3984BB VX3984PB VX3992BN VX3992BB VX3992PB VX3993BN VX3993BB VX3993PB  VX3061BN VX3061BB VX3061PB VX3062BN VX3062BB VX3062PB VX3991BN VX3991BB VX3991PB VX3996BN VX3996BB VX3996PB Black Nickel  Brushed Brass Polished Brass Black Insert White Insert Black Insert FLAT PLATE 2009 Volex 76pp  4/9/08  03:16  Page 39

The elegance of Georgian andthe sophistication of  Victorian provide two finishes to meet the needs ofany residential environment.Manufactured from quality cast brass,with oven-baked lacquer coating foradded protection.Volex cast brass isavailable fitted with black interiors asstandard, white available on request. Decorativ e  Brass 40 2009 Volex 76pp  4/9/08  03:16  Page 40

250W DIMMERS LIST NO DESCRIPTION CARTON QTY VB0250_ _PU 1 gang push on/off dimmer 10 VB0252_ _PU 2 gang push on/off dimmer 5 • Complies with EMC directive• Terminal suitable for 3x1.5mm 2 conductors • Can be used 1 or 2 way• For use with tungsten filament lamp only Dimensions 94.6mmx94.6mm Mounting box Flush metal:SB655 VB0252GEPU VB0252VIPU 400W DIMMERS LIST NO DESCRIPTION CARTON QTY VB0400_ _PU 1 gang push on/off dimmer 5 • Complies with EMC directive• Can be used 1 or 2 way• For use under tungsten filament lamp only Dimensions 94.6mmx94.6mm Mounting box Flush metal: SB655 VB0400GEPU VB0400VIPU Decorativ e Brass 41 Decorative Brass Accessories are available in the following finishes: GE-Georgian or VI-Victorian. Indicate the finish that you require by addingthe suffix to the list number. eg. VB1020GE 10AX PLATE SWITCHES LIST NO DESCRIPTION CARTON QTY VB1020 _ _  1 gang 2 way switch  5 VB1030 _ _  1 gang intermediate switch  5 VB1040 _ _ 2 gang 2 way switch  5 VB1050 _ _  3 gang 2 way switch  5 VB1054 _ _  4 gang 2 way switch  5 • BS EN 60669-1, BS3676• Terminals suitable for 4x1mm 2  2x2.5mm 2  or 3x1.5mm 2 conductors • Fully rated at 10AX for fluorescent loads Dimensions 1–3 gang: 94.6mmx94.6mm4 gang: 154.5mmx94.6mm Mounting boxes Flush metal: 1–3 gang SB623; 4 gang SB665 VB1020GE VB1020VI 2009 Volex 76pp  4/9/08  03:16  Page 41

20A DP SWITCHES LIST NO DESCRIPTION CARTON QTY VB1060 _ _  20A DP switch with neon  5 • BS EN 60669-1, BS3676• Terminals suitable for 3x2.5mm 2 or 2x4.0mm 2 conductor Dimensions 94.6mmx94.6mm Mounting boxes Flush metal:SB655Flush PVC:VX8111 VB1060GE VB1060VI VB9702GE VB9702VI 45A DP SWITCHES LIST NO DESCRIPTION CARTON QTY VB9702 _ _  45A DP switch with neon  5 • BS3676• Terminals suitable for up to 1x16mm 2 cable Dimensions 154.5mmx94.6mm Mounting box Flush metal:SB628 13A SOCKET OUTLETS LIST NO DESCRIPTION CARTON QTY VB1300 _ _  1 gang SP switched socket  5 VB1500 _ _  2 gang SP switched socket  5 • BS1363• Terminals suitable for up to 3x2.5mm 2 or 2x4.0mm 2 conductors • Double pole switching avaialble. Suffix list no. -/D i.e.VB1500GE/D• 2 gang DP sockets come with twin earth as standard Dimensions 1 gang: 94.6mmx94.6mm, 2 gang: 154.5mmx94.6mm Mounting boxes Flush metal: 1 gang SB655; 2 gang SB665 VB1500GE VB1500VI Decorativ e Brass 42 Decorative Brass Accessories are available in the following finishes: GE-Georgian or VI-Victorian. Indicate the finish that you require by addingthe suffix to the list number. eg. VB1020GE 2009 Volex 76pp  4/9/08  03:16  Page 42

VB1080GE VB1081VI 13A FUSED CONNECTION UNITS LIST NO DESCRIPTION CARTON QTY VB1080 _ _  Switched fuse connection unit  5 VB1081 _ _ Switched fuse connection unit with neon 5 • BS1363• Terminals suitable for 3x2.5mm 2 or 2x4.0mm 2 conductors Dimensions 94.6mmx94.6mm Mounting box Flush metal:SB655 BLANKING PLATES LIST NO DESCRIPTION CARTON QTY VB9991 _ _  1 gang  5 VB9996 _ _  2 gang  5 Dimensions 1 gang: 94.6mmx94.6mm2 gang: 154.5mmx94.6mm WHITE INTERIORS Both the Georgian and Victorian ranges are available in whiteAdd suffix W to list number, eg VB1300GEW Note: Some items may be made to order with white insert VB9991GE VB9991VI VB1500GEW VB1500VIW Decorativ e Brass 43 2009 Volex 76pp  4/9/08  03:16  Page 43

Designed for use in the industrial andcommercial environment, the VolexMetalclad range is manufactured frommild steel and coated in epoxy resin.Each product is supplied complete witha mounting box in a matching finish, fittedwith an earth terminal. Metalclad 44 2009 Volex 76pp  4/9/08  03:16  Page 44

10AX SWITCHES LIST NO DESCRIPTION CARTON QTY VX1010SG 1 gang 1 way 5 VX1020SG 1 gang 2 way 5 VX1030SG 1 gang intermediate 5 VX1040SG 2 gang 2 way 5 VX1050SG 3 gang 2 way 5 VX1054SG 4 gang 2 way 5 • BS EN 60669-1• Terminals suitable for 4x1.0mm 2, 3x1.5mm 2 , or 2x2.5mm 2  conductors • Fully rated at 10AX for fluorescent and inductive loads Dimensions 1 gang 86.7mmx86.7mmx44mm2 gang 143.9mmx86.7mmx44mm 20A DP CONTROL SWITCHES LIST NO DESCRIPTION CARTON QTY VX1060SG 1 gang with neon indicator 5 VX1060FSG 1 gang with neon, front flex outlet & cord grip 5 VX1070SG 1 gang 5 VX1070FSG 1 gang with front flex outlet & cord grip 5 • BS EN 60669-1• Terminals suitable for up to 3x2.5mm 2 to 2x4mm 2 conductors • Cord outlet, suitable for flexible cord up to 10mm 2 Dimensions 86.7mmx86.7mmx44mm VX1020SG VX1040SG VX1050SG VX1060SG VX1060FSG VX1070SG VX1070FSG Metalclad 45 2009 Volex 76pp  4/9/08  03:16  Page 45

13A SOCKET OUTLETS LIST NO DESCRIPTION CARTON QTY VX9100SG 1 gang socket 5 VX9200SG 2 gang socket 5 VX1300SG 1 gang SP switched 5 VX1500SG 2 gang SP switched 5 VX1400SG 1 gang SP switched with neon 5 VX1600SG 2 gang SP switched with neon 5 • BS1363• Terminals suitable for 3x2.5mm 2 or 2x4mm 2 conductors • Double pole switching available. Suffix list no. -/D i.e.VX1500SG/D• 2 gang DP sockets come with twin earth as standard Dimensions 1 gang: 86.7mmx86.7mmx44mm2 gang: 143.9mmx86.7mmx44mm VX1300SG VX1500SG 13A 30mA METALCLAD RCD PROTECTED SOCKETS& FCU LIST NO DESCRIPTION CARTON QTY VT1108SG 1 gang switched RCD protected socket outlet 1 VT1208SG 2 gang switched RCD protected socket outlet 1 VT1092SG RCD Fused Connection Unit 1 • Socket outlets to BS7288• FCU to BS4293• Double pole switching• Terminals suitable for 3x2.5mm 2 or 2x4.0mm 2 conductors Dimensions 1 gang: 86.7mmx86.7mmx44mm2 gang: 143.9mmx86.7mmx44mm VT1108SG VT1208SG VT1092SG 15A ROUND PIN SWITCHES LIST NO DESCRIPTION CARTON QTY VX9900SG Switched socket outlet 5 • BS546• 1 gang shuttered single pole Dimensions 86.7mmx86.7mmx44mm VX9900SG Metalclad 46 2009 Volex 76pp  4/9/08  03:16  Page 46

45A DP SWITCHES LIST NO DESCRIPTION CARTON QTY VX9702SG 45A DP switch with neon 1 VX9703SG 45A DP switch 1 • BS EN 60669-1• Terminals suitable for conductor sizes up to 1x16mm 2 • The following markings are available; add the appropriate suffix to the list number, eg VX9702SG/CK:COOKER – CKSHOWER – SHAIR CONDITIONING – AC Dimensions 143.9mmx86.7mmx44mm VX9702SG VX9703SG 13A FUSED CONNECTION UNITS LIST NO DESCRIPTION CARTON QTY VX1080SG DP switched 5 VX1080SG/F DP switched with front flex outlet & cord grip 5 VX1081SG DP switched with neon 5 VX1081SG/F DP switched with neon, front flex outlet & cord grip 5VX1090SG 13A unswitched 5 VX1090FSG 13A unswitched with front flex outlet & cord grip 5 VX1091SG 13A unswitched with neon 5 VX1091FSG 13A unswitched with neon, front flex outlet & cord grip 5 • BS1363• Terminals suitable for 3x2.5mm 2 or 2x4mm 2 conductors • Cord outlet suitable for flexible cord up to 10mm 2 Dimensions 86.7mmx86.7mmx44mm VX1080SG VX1080SG/F BLANKING PLATES LIST NO DESCRIPTION CARTON QTY VX9991SG 1 gang 5 VX9996SG 2 gang 5 Dimensions 1 gang 86.7mmx86.7mmx44mm2 gang 143.9mmx86.7mmx44mm VX9991SG VX9996SG Metalclad 47 2009 Volex 76pp  4/9/08  03:16  Page 47

2009 Volex 76pp  4/9/08  03:16  Page 48

The Volex Weatherproof Range offers a variety ofproducts designed to provide the protection neededwhen using power outdoors.The Switches, Socketsand Connection Units have been tested to IP55(dust and splash protected) and power controllers andenclosures have been tested to IP66 (dust tight andhose proof. The smooth aesthetics and tough build quality makethe range ideal for domestic and commercial usage.Applications include permanent installation forcontrolling exterior lighting and power to outdoorequipment such as ponds. Other uses include powerfor portable electrically operated devices such as    lawnmowers and power tools. Weatherpr oof 49 2009 Volex 76pp  4/9/08  03:16  Page 49

W eatherpr oof 50 20A SWITCHES IP55 LIST NO DESCRIPTION CARTON QTY VX5020 1 Gang 2 Way Switch 1 VX5040 2 Gang 2 Way Switch 1 BS EN 60669-1:2000, BS EN60529 Dimensions Knockouts Height 87mm 1 x 20mm Each side Width 74mm 1 x 20mm Top & Bottom Depth 60mm 1 x 20mm Back VX5020 VX5040 13A SOCKET OUTLETS IP55 LIST NO DESCRIPTION CARTON QTY VX5100 1 Gang Unswitched socket 1 VX5200 2 Gang Unswitched socket 1 VX5300 1 Gang Switched Socket 1 BS 1363, BS EN60529 Dimensions Knockouts 1 GangHeight 87mm 1 x 20mm Each side Width 74mm 1 x 20mm Top & Bottom Depth 60mm 1 x 20mm Back 2 GangHeight 94.5mm 1 x 20mm Each sideWidth 126mm 3 x 20mm Top & BottomDepth 60mm 1 x 20mm Back VX5100 VX5200 VX5300 13A FUSED CONNECTION UNITS IP55 LIST NO DESCRIPTION CARTON QTY VX5080 Switched Connection Unit 1 VX5090 Unswitched Connection Unit 1 BS 1363-4, BS EN60529 Dimensions Knockouts Height 87mm 1 x 20mm Each side Width 74mm 1 x 20mm Top & Bottom Depth 69mm 1 x 20mm Back VX5090 SWITCH POWER CONTROLLERS IP66 LIST NO DESCRIPTION CARTON QTY VX5030 3 Switch 13A Power Controller 1 VX5050 5 Switch 13A Power Controller 1 BS 1363-4, BS EN60529 Dimensions3 SwitchHeight 103mmWidth 160mmDepth 56mm 5 SwitchHeight 103mmWidth 225mmDepth 56mm Fixing centres - page 67 VX5030 VX5050 2009 Volex 76pp  4/9/08  03:16  Page 50

Metalclad 51 WEATHERPROOF ENCLOSURES IP66 LIST NO DESCRIPTION CARTON QTY VX5073 86 x 74 x 63mm 1 VX5123 86 x 125 x 63mm 1 VX5180 110 x 181 x 97mm 1 VX5270 186 x 276 x 132mm 1 BS5733, BS EN60529 Dimensions Knockouts VX5073 VX5073 Height 86mm 1 x 20mm Each side Width 74mm 1 x 20mm Top & Bottom Depth 63mm 1 x 20mm Back Dimensions Knockouts VX5123 VX5123 Height 86mm 1 x 20mm Each side Width 125mm 3 x 20mm Top & BottomDepth 63mm 1 x 20mm Back Dimensions Knockouts VX5180 VX5180 Height 110mm 2 x 20mm Each sideWidth 181mm 3 x 20mm Top & BottomDepth 97mm Dimensions Knockouts VX5270 VX5270 Height 186mm 2 x 20mm Each sideWidth 276mm 3 x 20mm Top & BottomDepth 132mm VX5073 VX5123 VX5180 VX5270 OUTDOOR POWER BOX IPX4 LIST NO DESCRIPTION CARTON QTY VX5001 224mm x 334mm x 161mm 1 DimensionsHeight 334mm Width 224mm Depth 161mm VX5001 ANCILLARY ITEMS LIST NO DESCRIPTION CARTON QTY VX5002 Cable Gland Pack IP66 (x2) 12 VX5003 Grommet Pack IP55 (x2) 14 VX5004 Cable Connector IP68 10 VX5002 BS EN60529, BS EN50262 VX5003 BS EN60529 VX5004 BS1363-4, BS EN60529 Fixing centres - page 67 VX5002 VX5003 VX5004 2009 Volex 76pp  4/9/08  03:16  Page 51

The Volex panel mounting range of interiors is suitable for a wide variety ofOEM applications, from perimeter trunking to decorative accessories.Available in white or black, the same quality features are offered as inthe rest of the accessory range, including double pole switching on socketsand arc shielding on 10AX and 20A switches. Interiors 52 2009 Volex 76pp  4/9/08  03:16  Page 52

10AX SWITCHES LIST NO DESCRIPTION CARTON QTY MC1020 1 gang 2 way 10 MC1030 1 gang intermediate 10 MC1040 2 gang 2 way 10 MC1050 3 gang 2 way 10 MC1054 4 gang 2 way 5 • BS EN 60669-1, BS3676• Terminals suitable for 4x1.0mm 2 , 3x1.5mm 2 , 2x2.5mm 2 conductors CONTROL SWITCHES LIST NO DESCRIPTION CARTON QTY MC1060 20A DP switch unit with neon 10 MC1070 20A DP switch unit 10 MC9702 45A DP switch unit with neon 5 • BS EN 60669-1, BS3676• MC1060 terminals suitable for 3x2.5mm 2 or 2x4.0mm 2 conductors • MC9702 terminals suitable for 1x16mm 2 conductor SOCKET OUTLETS LIST NO DESCRIPTION CARTON QTY MC9100 13A 1 gang Unswitched socket 10 MC9200 13A 2 gang Unswitched socket 5 MC1300 13A SP 1 gang switched socket 10 MC1500 13A SP 2 gang switched socket 5 MC9901 2A 1 gang Unswitched socket 10 • BS1363/BS5546 as appropriate• Terminals suitable for up to 3x2.5mm 2 or 2x4.0mm 2 conductors • Double pole switching available. Suffix list no. -/D ie MC 1500/D• 2 gang DP sockets come with twin earth as standard 13A FUSED CONNECTION UNITS LIST NO DESCRIPTION CARTON QTY MC1080 13A switched fused connection unit 10 MC1081 13A switched fused connection unit with neon 10 • BS1363• Terminals suitable for 3x2.5mm 2 or 2x4.0mm 2 conductors • Black mouldings available to order. Suffix list no. with  MC1040 MC1050BK MC1060 MC9702 MC1300 MC1500BK/D MC1080 MC1081 RCD SOCKETS & FCU LIST NO DESCRIPTION CARTON QTY MC1108 1 gang Switched RCD Socket Outlet 1 MC1208 2 gang Switched RCD Socket Outlet 1 MC1092 Fused Connection Unit 1 • Socket outlets to BS7288• FCU to BS4293• Double pole switching• Terminals suitable for 3x2.5mm 2 or 2x4.0mm 2 conductors MC1092 MC1208 COMMUNICATION OUTLETS LIST NO DESCRIPTION CARTON QTY MC9992 1 gang coaxial TV outlet, non-isolated 10 MC9993 2 gang coaxial TV outlet, non-isolated 10 MC9974 1 gang telephone master outlet 10 MC9984 1 gang telephone secondary outlet 10 MC9974 MC9993BK Interiors 53 For black interiors please add BK to the list number ie: MC9992BK 2009 Volex 76pp  4/9/08  03:16  Page 53

In the home, workshop or outdoors, any factors such as dampness, faulty wiring, frayedcords and other hazards can contribute towards a potentially lethal situation when usingelectric irons, extension leads, lawn mowers, hedge trimmers and other portable electricalequipment and appliances. Protector residual current device (RCD) products provide personal protection andminimise the risk of electric shock from earth faults. For added safety, the electronic sensing device within Protector products becomes activeonly when the reset button is pressed. Pr otector :RCD Wiring  Accessories 54 2009 Volex 76pp  4/9/08  03:16  Page 54

13A 30mA METALCLAD RCD PROTECTED SOCKETS& FCU LIST NO DESCRIPTION CARTON QTY VT1108SG 1 gang switched RCD protected socket outlet 1 VT1208SG 2 gang switched RCD protected socket outlet 1 VT1092SG RCD Fused Connection Unit 1 • Socket outlets to BS7288• FCU to BS4293• Double pole switching• Terminals suitable for up to 3x2.5mm 2 or 2x4.0mm 2 conductors Dimensions 1G: 86.7mmx86.7mmx44mm2G: 143.9mmx86.7mmx44mm VT1092 REWIREABLE RCD PLUG LIST NO DESCRIPTION CARTON QTY VT1952 13A 30mA rewireable RCD plug 1 • BS7071• Suitable for attaching to appliance cables to provide earth-fault protection to suit the user • Unit is mains dependant, so will trip out automatically on loss of power VT1952 PORTABLE RCD ADAPTOR LIST NO DESCRIPTION CARTON QTY VT1951 13A 30mA portable RCD adaptor 1 • BS7071• Suitable for use with most portable electric tools and appliances, providing earth-fault protection from the socket outlet • Unit is mains dependent, so will trip out automatically on loss of power VT1951 VT1108 VT1208 13A 30mA FLUSH RCD PROTECTED SOCKETS& FCU LIST NO DESCRIPTION CARTON QTY VT1108 1 gang switched RCD protected socket outlet 1 VT1208 2 gang switched RCD protected socket outlet 1 VT1092 RCD Fused Connection Unit 1 • Socket outlets to BS7288• FCU to BS4293• Double pole switching• Terminals suitable for up to 3x2.5mm 2 or 2x4.0mm 2 conductors Dimensions 1G: 86mmx86mm with 60.3mm fixing centresFCU: 86mmx86mm with 60.3mm fixing centres2G: 146mmx86mm with 120.6mm fixing centres Mounting boxes Surface moulded: 1G & FCU:VX9405 2G:VX9417Flush metal: 1G & FCU: SB615 2G: SB625 Pr otector :RCD  Wiring  Accessories 55 VT1108SG VT1208SG 2009 Volex 76pp  4/9/08  03:16  Page 55

2009 Volex 76pp  4/9/08  03:16  Page 56

Consumer Unit 57 The Volex Circuit Protection range includes Insulatedand full Metal cased Consumer Units, MCBs, RCCBs,and one and two module RCBOs.Mainswitch and RCCB Incomer units range from 2 to19 outgoing ways, Splitload units 6, 9, 12 and 17 outgoingways, High Integrity and Dual RCD units in a variety of10 and 15 outgoing ways. The Range is designed to be easy to install and ideally   suited to domestic applications with: ● Full DIN rail which allows for use of DIN Accessories ie:Timers, Contactors ● Raised DIN rail providing top andbottom wiring routes ● Large cable entries for single point cable  entry applications ● Neutral and Earth terminals all at the top of the enclosure ● Large Enclosures allowing additionalwiring space ●   All round cable entry - top, bottom, sides and rear 2009 Volex 76pp  4/9/08  03:16  Page 57

VCU14MS VCU12SLF VCU31 VCU16 MAIN SWITCH INCOMER LIST NO DESCRIPTION VCU2MS 2 way Insulated Consumer Unit 63A Incomer VCU5MS 5 way Insulated Consumer Unit 100A Incomer VCU8MS 8 way Insulated Consumer Unit 100A Incomer VCU11MS 11 way Insulated Consumer Unit 100A Incomer VCU14MS 14 way Insulated Consumer Unit 100A Incomer VCU19MS 19 way Insulated Consumer Unit 100A Incomer DUAL RCD LIST NO DESCRIPTION VCU16 5 + 5 Dual RCD Splitload Consumer Unit VCU17 7 + 8 Dual RCD Splitload Consumer Unit HIGH INTEGRITY LIST NO DESCRIPTION VCU31 10 way High Integrity MS+2 RCD+4 RCD+4 VCU32 10 way High Integrity MS+4 RCD+3 RCD+3 VCU33 15 way High Integrity MS+2 RCD+6 RCD+7 VCU34 15 way High Integrity MS+4 RCD+6 RCD+5 VCU35 15 way High Integrity MS+6 RCD+5 RCD+4 SPLITLOAD BOARD LIST NO DESCRIPTION VCU6SLF 6 way Insulated Flexible Splitload Consumer Unit VCU9SLF 9 way Insulated Flexible Splitload Consumer Unit VCU12SLF 12 way Insulated Flexible Splitload Consumer Unit VCU17SLF 17 way Insulated Flexible Splitload Consumer Unit Insulated Consumer Unit 58 2009 Volex 76pp  4/9/08  03:16  Page 58

RCD INCOMER LIST NO DESCRIPTION VCU2RCD 2 way Consumer Unit 63A 30mA Incomer VCU5RCD 5 way Consumer Unit 80A 30mA Incomer VCU8RCD 8 way Consumer Unit 80A 30mA Incomer VCU11RCD 11 way Consumer Unit 80A 30mA Incomer VCU14RCD 14 way Consumer Unit 80A 30mA Incomer VCU19RCD 19 way Consumer Unit 80A 30mA Incomer VCUSHOWERKIT 2 way Consumer Unit 63A 30mA Incomer populated with 1x 50A MCB VCGKIT 2 way IP65 consumer unit 40A 30mA RCD Incomer populated with 1x 16A MCB VCU14RCD Consumer Unit 59 17 th EDITION SOLUTIONS USING VOLEX CONSUMER UNITS 100A DP MAIN SWITCH 40A RCBO 40A RCBO 32A RCBO 32A RCBO 32A RCBO 16A RCBO 6A RCBO 6A RCBO 6A RCBO 6A RCBO SPARE SMOKE ALARM BA THROOM LIGHTS UPST AIRS LIGHTS DOWNST AIRS LIGHTS IMMERSION HEA TER KITCHEN SOCKETS UPST AIRS SOCKETS DOWNST AIRS SOCKETS SHOWER COOKER MAIN SWITCH UNIT Utilising RCBOs throughout would provide a secure dedicated 30mA protected supply to every circuit. Example of a typical Installation where complete 30mA protection and all independent circuits are required. SPARE SPARE 100A DP MAIN SWITCH 6A RCBO 6A RCBO 6A RCBO 32A RCBO 40A RCBO BA THROOM LIGHTS UPST AIRS LIGHTS KITCHEN SOCKETS DOWNST AIRS  LIGHTS COOKER SHOWER SMOKE ALARM IMMERSION HEA TER DOWNST AIRS SOCKETS UPST AIRS  SOCKETS 6A MCB 16A MCB 32A MCB 32A MCB 40A MCB 80A 30mA RCCB SPLIT LOAD UNIT A small group of circuits on the RCD and all others on independent devices (RCBO). Example of a typical Installation where complete 30mA protection and some independent circuits are required. 63A 30mA RCCB 6A MCB 32A MCB 40A MCB BA THROOM LIGHTS SMOKE ALARM SHOWER 100A DP MAIN SWITCH DOWNST AIRS SOCKETS UPST AIRS LIGHTS 32A MCB KITCHEN SOCKETS HALL & ST AIRS LIGHTS COOKER UPST AIRS SOCKETS DOWNST AIRS  LIGHTS 6A MCB 6A MCB 32A MCB 40A MCB 6A RCBO 6A RCBO 63A 30mA RCCB HIGH INTEGRITY CONSUMER UNIT Uses two RCD protected sections and a number of ways for dedicated (High Integrity) circuits using 30mA RCBOs. Example of a typical Installation where complete 30mA protection is required and two independent circuits are necessary. 100A DP MAIN SWITCH 40A MCB 63A 30mA RCCB 80A 30mA RCCB 32A MCB 32A MCB 6A MCB 6A MCB 6A MCB 6A MCB 6A MCB 32A MCB SPARE BA THROOM LIGHTS UPST AIRS LIGHTS KITCHEN SOCKETS BURGLAR ALARM COOKER DOWNST AIRS SOCKETS DOWNST AIRS  LIGHTS HALL & ST AIRS LIGHTS UPST AIRS SOCKETS DUAL RCD CONSUMER UNIT Comprises of two sections - each protected by a 30mA RCD. Example of a typical Installation where complete 30mA protection is required, but no independent circuits are necessary. 2009 Volex 76pp  4/9/08  03:16  Page 59

Metal Consumer Unit 60 VCU5MMS VCU9MSLF VCU41 VCU26 MAIN SWITCH INCOMER LIST NO DESCRIPTION VCU2MMS 2 way Metal Consumer Unit 63A Incomer VCU5MMS 5 way Metal Consumer Unit 100A Incomer VCU8MMS 8 way Metal Consumer Unit 100A Incomer VCU11MMS 11 way Metal Consumer Unit 100A IncomerVCU14MMS 14 way Metal Consumer Unit 100A IncomerVCU19MMS 19 way Metal Consumer Unit 100A Incomer DUAL RCD LIST NO DESCRIPTION VCU26 5 + 5 Dual RCD Splitload Consumer Unit VCU27 7 + 8 Dual RCD Splitload Consumer Unit Metal Dual RCD boards are made to order HIGH INTEGRITY LIST NO DESCRIPTION VCU41 10 way High Integrity MS+2 RCD+4 RCD+4 VCU42 10 way High Integrity MS+4 RCD+3 RCD+3 VCU43 15 way High Integrity MS+2 RCD+6 RCD+7 VCU44 15 way High Integrity MS+4 RCD+6 RCD+5 VCU45 15 way High Integrity MS+6 RCD+5 RCD+4 Metal High Integrity boards are made to order SPLITLOAD BOARD LIST NO DESCRIPTION VCU6MSLF 6 way Metal Flexible Splitload Consumer Unit VCU9MSLF 9 way Metal Flexible Splitload Consumer Unit VCU12MSLF 12 way Metal Flexible Splitload Consumer UnitVCU17MSLF 17 way Metal Flexible Splitload Consumer Unit 2009 Volex 76pp  4/9/08  03:16  Page 60

Consumer Unit 61 RCD INCOMER LIST NO DESCRIPTION VCU2MRCD 2 way Metal Consumer Unit 63A 30mA Incomer VCU5MRCD 5 way Metal Consumer Unit 80A 30mA Incomer VCU8MRCD 8 way Metal Consumer Unit 80A 30mA Incomer VCU11MRCD 11 way Metal Consumer Unit 80A 30mA IncomerVCU14MRCD 14 way Metal Consumer Unit 80A 30mA IncomerVCU18MRCD 19 way Metal Consumer Unit 80A 30mA Incomer VCU2MRCD 17 th EDITION SOLUTIONS USING VOLEX CONSUMER UNITS 100A DP MAIN SWITCH 40A RCBO 40A RCBO 32A RCBO 32A RCBO 32A RCBO 16A RCBO 6A RCBO 6A RCBO 6A RCBO 6A RCBO SPARE SMOKE ALARM BA THROOM LIGHTS UPST AIRS LIGHTS DOWNST AIRS LIGHTS IMMERSION HEA TER KITCHEN SOCKETS UPST AIRS SOCKETS DOWNST AIRS SOCKETS SHOWER COOKER MAIN SWITCH UNIT Utilising RCBOs throughout would provide a secure dedicated 30mA protected supply to every circuit. Example of a typical Installation where complete 30mA protection and all independent circuits are required. SPARE SPARE 100A DP MAIN SWITCH 6A RCBO 6A RCBO 6A RCBO 32A RCBO 40A RCBO BA THROOM LIGHTS UPST AIRS LIGHTS KITCHEN SOCKETS DOWNST AIRS  LIGHTS COOKER SHOWER SMOKE ALARM IMMERSION HEA TER DOWNST AIRS SOCKETS UPST AIRS  SOCKETS 6A MCB 16A MCB 32A MCB 32A MCB 40A MCB 80A 30mA RCCB SPLIT LOAD UNIT A small group of circuits on the RCD and all others on independent devices (RCBO). Example of a typical Installation where complete 30mA protection and some independent circuits are required. 63A 30mA RCCB 6A MCB 32A MCB 40A MCB BA THROOM LIGHTS SMOKE ALARM SHOWER 100A DP MAIN SWITCH DOWNST AIRS SOCKETS UPST AIRS LIGHTS 32A MCB KITCHEN SOCKETS HALL & ST AIRS LIGHTS COOKER UPST AIRS SOCKETS DOWNST AIRS  LIGHTS 6A MCB 6A MCB 32A MCB 40A MCB 6A RCBO 6A RCBO 63A 30mA RCCB HIGH INTEGRITY CONSUMER UNIT Uses two RCD protected sections and a number of ways for dedicated (High Integrity) circuits using 30mA RCBOs. Example of a typical Installation where complete 30mA protection is required and two independent circuits are necessary. 100A DP MAIN SWITCH 40A MCB 63A 30mA RCCB 80A 30mA RCCB 32A MCB 32A MCB 6A MCB 6A MCB 6A MCB 6A MCB 6A MCB 32A MCB SPARE BA THROOM LIGHTS UPST AIRS LIGHTS KITCHEN SOCKETS BURGLAR ALARM COOKER DOWNST AIRS SOCKETS DOWNST AIRS  LIGHTS HALL & ST AIRS LIGHTS UPST AIRS SOCKETS DUAL RCD CONSUMER UNIT Comprises of two sections - each protected by a 30mA RCD. Example of a typical Installation where complete 30mA protection is required, but no independent circuits are necessary. 2009 Volex 76pp  4/9/08  03:16  Page 61

Consumer Unit De vices 62 1 MODULE RCBOs LIST NO DESCRIPTION VRCBO06/1 6A 30mA One Module Single Pole RCBO VRCBO10/1 10A 30mA One Module Single Pole RCBO VRCBO16/1 16A 30mA One Module Single Pole RCBO VRCBO20/1 20A 30mA One Module Single Pole RCBO VRCBO32/1 32A 30mA One Module Single Pole RCBO VRCBO40/1 40A 30mA One Module Single Pole RCBO MCBs LIST NO DESCRIPTION VB06  6A Type B 6kA   VB10  10A Type B 6kA    VB16 16A Type B 6kA   VB20  20A Type B 6kA   VB32  32A Type B 6kA   VB40  40A Type B 6kA   VB50  50A Type B 6kA   BLANKS LIST NO DESCRIPTION VBL 2 x  1 / 2 module blank VBLPP Twist fit 1 module Blank VCUBLPP Combined 1 way cover & Busbar Blank 2 MODULE RCBOS LIST NO DESCRIPTION VRCBO0630 6A 30mA Two Module Double Pole RCBO VRCBO1030 10A 30mA Two Module Double Pole RCBO VRCBO1630 16A 30mA Two Module Double Pole RCBO VRCBO2030 20A 30mA Two Module Double Pole RCBO VRCBO3230 32A 30mA Two Module Double Pole RCBO VRCBO4030 40A 30mA Two Module Double Pole RCBO RCDS LIST NO DESCRIPTION VR25 25A 30mA Double Pole VR40 40A 30mA Double Pole VR63 63A 30mA Double Pole VR80 80A 30mA Double Pole ENCLOSURES LIST NO DESCRIPTION VRE2 2 Module IP40 Enclosure VBLPP VCUBLPP VRCBO40/1 VRCBO3230 VR80 VRE2 2009 Volex 76pp  4/9/08  03:16  Page 62

TECHNICAL DATA& NUMERIC INDEX F G H I R0.6 0.5 R1 R1.6 K E L J C D A B E MC1080   VCU 6SLF VX9706 VX1010 T echnical  Information  & Numeric  Index 63 VX1500 2009 Volex 76pp  4/9/08  03:16  Page 63

WIRING CIRCUITS FOR 10AX SWITCHES One way circuits Two way circuits Intermediate circuits TECHNICAL CAPACITIES (mm 2 ) The following table summarises the terminal capacities of theprincipal wiring accessories. Description Conductor size 10AX switches 4x1mm 2 , 3x1.5mm 2 , 2x2.5mm 2 20A DP switch 3x2.5mm 2 , 2x4.0mm 2 , 1x6.0mm 2 , 1x10mm 2 45A DP switch 2x6.0mm 2 , 1x10mm 2 , 1x16mm 2 13A socket outlet 3x2.5mm 2 , 2x4.0mm 2 13A fused connection unit 3x2.5mm 2 , 2x4.0mm 2 RECOMMENDED QUANTITY OF SOCKETOUTLETS FOR DOMESTIC INSTALLATIONS An installation may have too few socket outlets or the existingsocket outlets may be incorrectly situated. Both conditions aresymptomatic of an inadequate installation which could lead topotentially dangerous improvisation. The following is a summary of the recommendations of theElectrical Installation Industry Liaison Committee.All socketoutlets should be of the twin switched type. Room Number of sockets Kitchen 6 Lounge 6 Dining room 4 Double bedroom 4 Single bed-sitting room 4 Single bedroom 4 Landing/Stairs 1 Hall 2 Garage 2 Store/Workroom 2 Central heating boiler point 1 L1 L2 L2 L1 L3 L3 N L L1 L2 L2 L1 L3 L3 N L N L L1 L2 N L L2 N2 N1 L1 L1 L2 L1 L2 L2 L1 L3 L3 L4 L3 N L L1 L2 L1 L2 L2 L1 L3 L3 L4 L3 N L T echnical  Inf ormation 64 2009 Volex 76pp  4/9/08  03:16  Page 64

T echnical  Information 65 Moulded (surface) Metal (flush) Drylining (flush) Product List no box List no box List no box List no 10A switch 1 gang VX1010 VX9404 SB623 SB619 10A switch 1 gang VX1020 VX9404 SB623 SB619 10A switch 1 gang VX1030 VX9404 SB623 SB619 10A switch 2 gang VX1040 VX9404 SB623 SB619 10A switch 3 gang VX1050 VX9404 SB623 SB619 10A switch 4 gang VX1054 VX9412 SB665 SB629 13A socket 1 gang VX9100 VX9409 SB655 SB619 13A socket 1 gang VX1300 VX9409 SB655 SB619 13A socket 1 gang VX1400 VX9409 SB655 SB619 13A socket 2 gang VX9200 VX9414 SB665 SB629 13A socket 2 gang VX1500 VX9414 SB665 SB629 13A socket 2 gang VX1600 VX9414 SB665 SB629 13A socket 2 gang VX1700 VX9414 SB665 SB629 13A socket 2 gang VX1800 VX9414 SB665 SB629 13A socket 3 gang VX9230 VX9403 SB646 – 20A switch VX1060 VX9409 SB655 SB619 20A switch VX1070 VX9409 SB655 SB619 50A ceiling switch VX9706 VX9405 – – 45A switch VX9702 VX9416 SB628 SB631 45A switch VX9703 VX9416 SB628 SB631 45A switch VX9712 VX9405 SB618 SB632 45A switch VX9713 VX9405 SB618 SB632 Cooker unit VX9700 VX9416 SB628 SB631 Cooker unit VX9701 VX9416 SB628 SB631 Fused connection unit VX1080 VX9409 SB655 SB619 Fused connection unit VX1081 VX9409 SB655 SB619 Fused connection unit VX1090 VX9409 SB655 SB619 Fused connection unit VX1091 VX9409 SB655 SB619 Telephone socket VX9974 VX9404 SB655 SB619 Secondary socket VX9984 VX9404 SB655 SB619 2 module mounting plate VX9062 VX9405 SB615 SB619 4 module mounting plate VX9064 VX9416 SB625 SB629 Shaver unit VX9800 VX9410 SB628 SB631 TV outlet 1 gang VX9992 VX9409 SB655 SB619 TV outlet 2 gang VX9993 VX9409 SB655 SB619 13A flex outlet plate VX9990 VX9409 SB655 SB619 Cooker outlet plate VX9704 VX9405 SB615 SB632 GUIDANCE ON THE USE OF LAMPHOLDERS MARKED T1 OR T2 The information in the table is a guide to theuser of lampholders marked T1 or T2 withtungsten filament lamps, although it shouldbe appreciated that the critical factor is theactual temperature of the cap of the lampwhen in use.Technical information on suchtemperatures is contained in this specificationand in BS EN 60598-1. It is also important toensure that the wattage rating of the lamp isnot higher than that for which the particularshade or luminaire is designed.This maximumrating in watts is marked on all shades andluminaires that comply with BS4533: Part101.The recommendations in the table refer totypical conditions, in single lamp luminaires orinstallations, and in multi lamp luminaireshaving widely spaced lamps.Where lamps arein close proximity to each other, or in totallyenclosed luminaires, it is recommended thatT2 lampholders are used. SBC Small bayonet cap (international type B15d) BC Standard bayonet cap (international type B22d) T1 Lampholder suitable for conditions up to a lamp captemperature of 165°C T2 Lampholder suitable for conditions up to a lamp captemperature of 210°C Closed shade Shade open at one end only and generallymounted directly on the lampholder Open shade Shade open at both ends, and generallymounted on the lampholder by a wire frame Cap up Position of lamp, typically when suspended fromthe ceiling by a flexible cord Cap down Position of lamp, typically when fitted on astandard or table lamp Where two symbols are shown together, as inB15d-T1/T2 or B22d-T2, there is no restriction onthe type of shade or the position of the lamp, pro-vided the maximum working temperatures are notexceeded If in doubt regarding the choice of any lampholder,always use one marked T2 RECOMMENDED MOUNTING BOXES FOR MOULDED VOLEX WIRING ACCESSORIES Flush box recommendationsas shown in the adjacenttable. Industrial metalcladaccessories(suffix SG) are suppliedcomplete with matchingsurface mounting boxes. Maximum permitted rating of lamp Typical conditions of use Maximum Lampholder Type of shade Lamp position permitted Size Type Temperature Closed Open Cap up Cap down rating of lamp SBC B15d T1 40W SBC B15d T2 60W BC B22d T1 – – 60W BC B22d T1 – – 100W BC B22d T1 – – 150W BC B22d T1 – – 200W BC B22d T2 200W CFL COMPACT FLUORESCENT LAMPHOLDER The design of the Lampholder accepts an industry standard 4 pin 10/13 Watt Compact Fluorescent G24 lamp.This reduces the power consumption,when compared to an equivalent incandescent lamp, by up to 80%. The Lampholder is designed to European standards and has a diameter of 42mm, which is larger than the typical Lampholder which is 29mm. A Safety feature which protects the installation will disconnect the supply to the Lampholder:-During a lamp change, when no lamp is present, or in the case of lamp failure at the end of lamp life.This Safety feature is reset by switching the supply to the fitting off for 10 to 15 seconds. 2009 Volex 76pp  4/9/08  03:17  Page 65

T echnical  Inf ormation 66 DECORATIVE WIRING  ACCESSORIES l RECOMMENDED MOUNTING BOXES FOR DECORATIVE WIRING ACCESSORIES l DIMENSION & CLOSE COUPLING DETAILS Description PROFILE A B C D Flatplate 1 Gang 87.2mm 87.2mm 2mm 7.45mm Flatplate 2 Gang 87.2mm 147.2mm 2mm 7.3mm Round Edge 1 Gang 86.5mm 86.5mm 8.2mm 7.1mm Round Edge 2 Gang 86.5mm 147mm 8.2mm 7.2mm Curved Edge 1 Gang 84.4mm 84.4mm 8mm 6.05mm Curved Edge 2 Gang 84.4mm 145.6mm 8mm 6.5mm Angled Edge 1 Gang 89.7mm 89.7mm 8.2mm 8.7mm Angled Edge 2 Gang 89.7mm 150mm 8.2mm 8.7mm Decorative Brass 1 Gang 95.7mm 95.7mm 10.4mm 11.7mm Decorative Brass 2 Gang 95.7mm 155mm 10.4mm 11.2mm A B C D D BRITISH STANDARDS Light Switches BS EN 60669-1 Intermediate Switches BS EN 60669-1 Pull Switches BS EN 60669-1 Fan Isolator BS EN 60974-3 Toggle Switch BS EN 60669-1 Standard Dimmer BS EN 55014, BS EN 60669-1 Low Voltage Dimmer BS EN 55014, BS EN 60669-1 Touch & Remote Dimmer BS EN 55014, BS EN 60669-1 BRITISH STANDARDS Switched Sockets BS EN 1363  Fuse Connection Units BS EN 1363 20A DP Switches BS EN 60669-1 45A DP Switches BS EN 60669-1 Shaver Socket BS EN61558 Co-Axial Socket BS 3041 Raised Plate Flat Plate Minimum Metal Flush Dry Lining Description List no List no Gang Box box Size box List no box List no 10AX 1 gang 2 way Switch VX1020_ _ VX3020_ _ 1 16mm SB623 SB619 10AX 2 gang 2 way Switch VX1040_ _ VX3040_ _ 1 16mm SB623 SB619 10AX 1 gang Intermediate Switch VX1010_ _ VX3030_ _ 1 16mm SB623 SB619 10AX 3 gang 2 way Switch VX1050_ _ VX3050_ _ 1 16mm SB623 SB619 10AX 4 gang 2 way Switch VX1054_ _ VX3054_ _ 2 16mm SB633 SB629 Fan Isolator VX1013_ _ VX3013_ _ 1 25mm SB655 SB619 1 gang 2 way Toggle Switch VX1120_ _ VX3120_ _ 1 25mm SB655 SB619 1 gang Intermediate Toggle Switch VX1130_ _ VX3130_ _ 1 25mm SB655 SB619 2 gang 2 way Toggle Switch VX1140_ _ VX3140_ _ 1 25mm SB655 SB619 3 gang 2 way Toggle Switch VX1150_ _ VX3150_ _ 1 25mm SB655 SB619 1 gang 2 way 400W Low Voltage/Mains Dimmer VX0400LV_ _PU VX3400LV_ _PU 1 35mm SB615 SB619 2 gang 2 way 250W Low voltage/mains Dimmer VX0252LV_ _PU VX33252LV_ _PU 1 25mm SB655 SB619 3 gang 2 way 250W Low voltage/mains Dimmer VX0253LV_ _PU VX3253LV_ _PU 2 25mm SB665 SB629 1 gang 2 way 400W Mains Dimmer VX0400_ _PU VX3400_ _PU 1 35mm SB615 SB619 2 gang 2 way 250W Mains Dimmer VX0252_ _PU VX3252_ _PU 1 25mm SB655 SB619 3 gang 2 way 250W Mains Dimmer VX0253_ _PU VX3253_ _PU 2 25mm SB655 SB629 4 gang 2 way 250W Mains Dimmer VX0254_ _PU VX3254_ _PU 2 25mm SB655 SB629 1 way 500W/500VA Touch Dimmer VX0500TD_ _ VX3005TD_ _ 1 35mm SB615 SB619 1 way 400W Touch Remote Dimmer VX0400TRD_ _ VX3400TRD_ _ 1 35mm SB615 SB619 5A 3 pin socket VX9905_ _ VX3905_ _ 1 25mm SB655 SB619 13A 1 gang DP Switched Socket VX1300_ _ /D VX3300_ _/D 1 25mm SB665 SB629 13A 2 gang DP Switched Socket VX1500_ _ /D VX3500_ _/D 2 25mm SB665 SB629 13A Unswitched Fused Connection Unit VX1090_ _ VX3090_ _ 1 25mm SB655 SB619 13A DP Switched Fused Connection Unit VX1080_ _ VX3080_ _ 1 25mm SB655 SB619 13A DP Switched Fused Connection Unit with Neon VX1081_ _ VX3081_ _ 1 25mm SB655 SB619 20A 1 gang DP Switch with Neon VX1060_ _ VX3060_ _ 1 25mm SB655 SB619 1 gang 45A Switch VX9713_ _ VX3713_ _ 1 47mm SB618 SB632 2 gang 45A Switch VX9703_ _ VX3703_ _ 2 47mm SB628 SB631 Cooker control unit with Neon VX9700_ _ VX3700_ _ 2 47mm SB628 SB631 Shaver Socket VX9800_ _ VX3800_ _ 2 47mm SB628 SB631 Telephone Master Socket VX9974_ _ VX3974_ _ 1 25mm SB655 SB619 Telephone Secondary Socket VX9984_ _ VX3984_ _ 1 25mm SB655 SB619 1 gang Co-Axial TV Socket VX9992_ _ VX3992_ _ 1 25mm SB655 SB619 2 gang Co-Axial TV Socket VX9993_ _ VX3993_ _ 1 25mm SB655 SB619 1 gang Blanking off plate VX9991_ _ VX3991_ _ 1 16mm SB623 SB619 2 gang Blanking off plate VX9996_ _ VX3996_ _ 2 16mm SB633 SB629 1 gang 1 module communication plate VX9061_ _ VX3061_ _ 1 16mm SB623 SB619 1 gang 2 module communication plate VX9062_ _ VX3062_ _ 1 16mm SB623 SB619 Note: Box size is based on boxes being mounted at least 5mm below plaster depth 2009 Volex 76pp  4/9/08  03:17  Page 66

T echnical  Information 67 IP RATINGS l The IP ( Ingress Protection) rating given to an enclosure states the degree of protection it offers by means of two digits.A summary of these is shown below; for a more detailed definition, see IEC 529: 1989, BS EN 60529: 1992. The letter X can be used in place of the first or second digit toindicate that tests have either not been made or are not applicable.N0TE:In the event of additional holes being drilled /pierced or knockouts removed,suitable measures should be taken to restore the products to the originalratings. IEC 529, BS EN 60529 does not apply to protection against the risk ofexplosion or conditions such as humidity, corrosive gases, fungi or vermin.n certain cases equipment designed to be mounted in an enclosure willcontribute towards the stated IP rating (eg pushbuttons mounted in an nclosure). Different parts of enclosures can have different degrees ofprotection and still conform to the standard (eg enclosures with pre-drilledconduit entry). FIRST DIGIT Protection against solid foreign objects and access to hazardous parts The first digit covers protection against penetration by solid objects, which includeshands and tools such as screwdrivers. At the lowest of seven levels, 0, no protectionis offered, either of the equipment itself from damage by intrusion or of a personcontacting live or moving parts. At the highest, 6, there shall be no entry of dust. SECOND DIGIT Protection against ingress of waterThe second digit covers the degree of protection against the entry of water, on aprogressive scale. For example, number 1 indicates that dripping water shall have noharmful effect, and number 6, that water projected in powerful jets against theenclosure from any direction shall have no harmful effects. A B FIXING CENTRES List Number A B VX5020 63mm 54mm VX5040 63mm 54mm VX5100 63mm 54mm VX5200 56mm 111mm VX5300 56mm 111mm VX5080 - 46mm VX5090 - 46mm List Number A B VX5030 44mm 122mm VX5050 44mm 195mm VX5073 - 46mm VX5123 - 96mm  VX5180 50mm 120mm VX5270 116mm 206mm 50mm 12mm 2.5mm 1.5mm 60 0 Not protected 1 Protected against solid objectsgreater than 50mm diameter 0 Not protected 1  Protected against dripping water  Protected against dripping water 2 when tilted up to 15 degrees 3 Protected against spraying water 4 Protected against splashing water 5 Protected against water jets 6 Protected against powerfuljets of water 7 Protected against the effectsof immersion 8 Protected against submersion 2 Protected against solid objectsgreater than 12mm diameter 3 Protected against solid objectsgreater than 2.5mm diameter 4 Protected against solid objectsgreater than 1.5mm diameter 5 Dust protected 6 Dust tight 2009 Volex 76pp  4/9/08  03:17  Page 67

T echnical Inf ormation 68 CUT OUT DETAILS FOR INTERIOR RANGE (dimensions in mm) 10AX/20A switch interiors LIST NO A B C D E F All 1 gang 60.3 17.1 30.6 – – – MC1040 60.3 33.4 30.6 – – – MC1050 60.3 49.7 30.6 – – – MC1054 120.6 33.4 30.6 40.2 – – MC1060 60.3 17.1 30.6 28.4 4.5 9.4 to 4.7 MC1013 60.3 47.9 30.6 D A B B C R1.0 B A C R1.0 A C R1.0 B D F E 45A DP switch LIST NO A B C D E F MC9702 120.7 42.2 24.5 34.9 9.4 4.5 to 4.7 C B R1.5 A E F D 13A Fused connection units LIST NO A B C D E F G H I J K MC1080 60.3 48.0 17.0 38.0 29.0 – 14.0 14.0 – – – MC1081 60.3 48.0 17.0 38.0 29.0 23.0 14.0 14.0 9.45 11.35 20.3 to to 9.60 11.50 MC1090 60.3 22.0 17.0 38.0 29.0 – 14.0 14.0 – – – MC1091 60.3 22.0 17.0 38.0 29.0 23.0 14.0 14.0 9.45 11.35 20.3 to to 9.60 11.50 F J I K B A C D E G H Telephone outlets LIST NO A B C D MC9974 60.3 23.3 20.3 4.6 MC9984 60.3 23.3 20.3 4.6 C A B D R1.5 Coaxial outlet LIST NO A B C MC9992 60.3 – 17.3 MC9993 60.3 25.4 17.3 A C A C C B 13A single socket outlet interiors LIST NO A B C D E F G H I J K L M N MC1300 60.3 12.0 15.4 5.7 28.6 30.4 10.8 38.8 14.2 38.4 – – – – MC1400 60.3 12.0 15.4 5.7 28.6 30.4 10.8 38.8 14.2 38.4 23.0 11.35 9.45 20.3 to to 11.50 9.60 13A twin socket outlet interiors LIST NO A B C D E F G H I J K L MC1500 120.6 84.4 30.4 5.7 14.2 38.4 – – – 28.6 29.9 – MC1600 120.6 84.4 30.4 5.7 14.2 38.4 23.0 11.35 9.45 28.6 29.9 101.2 to to 11.50 9.60 RCD socket outlet interiors LIST NO A B C D E F G H I J K L M N O P Q MC1092 60.3 14.39 38.4 27.15 13.4 44.46 37.85 24.4 10.25 20.5 12.0 33.59 - - - - - MC1108 60.3 19.0 24.6 26.4 38.4 12.3 29.55 12.1 27.15 13.4 46.45 38.35 26.4 12.2 36.7 36.35 - MC1208 38.40 19.0 24.6 36.35 27.15 26.05 28.3 12.1 27.15 13.4 26.4 37.65 46.45 12.2 68.0 86.4 36.7 J K L M R0.6 0.5 R1.0 R1.6 I N B C E F D G H A I F G H I R0.6 0.5 R1 R1.6 K E L J C D A B E A Q O N P B J I E C F H G D L R2.70 R3.30 K M R2.70 R1.70 R2.30 R1.60 R2.30 60˚ O N B H D C F G P L M K A R2.70 11.20 R2.70 R2.30 R3.30 R1.60 J I E R1.60 60˚ 19.50 27.50 I J B K L G H F A R1.70 R2.70 R1.60 E D C R2.30 60˚ 2009 Volex 76pp  4/9/08  03:17  Page 68

T echnical Inf ormation 69 SSp peecciiffiiccaattiio on n Standards Terminal Tripping Rated Compliance capacities Characteristic Voltage Consumer Units BS EN 60439-3 Main Switch BS EN 60947-3  35mm 230V RCCBs  BS EN 61008-1 35mm  Type AC 230V MCBs  BS EN 60898 25mm Type B, 6kA 230V RCBOs  BS EN 61009 25mm Type C, 6kA 30mA 230V D Diim meen nssiio on nss INSULATED M Maaiin n  SSw wiittcch h List No A B C VCU2MS 141 225 111 VCU5MS 194 225 111 VCU8MS 248 225 111 VCU11MS 302 225 111 VCU14MS 355 225 111 VCU19MS 445 225 111 SSp plliittllo oaad d  B Bo oaarrd d List No A B C VCU6SLF 248 225 111 VCU9SLF 302 225 111 VCU12SLF 355 225 111 VCU17SLF 445 225 111 R RC CD D  IIn ncco om meerr List No A B C VCU2RCD 141 225 111 VCU5RCD 194 225 111 VCU8RCD 248 225 111 VCU11RCD 302 225 111 VCU14RCD 355 225 111 VCU19RCD 445 225 111 D Du uaall  R RC CD D List No A B C VCU16 335 225 111 VCU17 445 225 111 H Hiiggh h  IIn ntteeggrriittyy List No A B C VCU31 355 225 111 VCU32 355 225 111 VCU33 445 225 111 VCU34 445 225 111 VCU35 445 225 111 D Diim meen nssiio on nss METAL M Maaiin n  SSw wiittcch h List No A B C VCU2MMS 126 210 96 VCU5MMS 188 238 123 VCU8MMS 241 238 123 VCU11MMS 292 238 123 VCU14MMS 345 238 123 VCU19MMS 438 238 123 SSp plliittllo oaad d  B Bo oaarrd d List No A B C VCU6MSLF 241 238 123 VCU9MSLF 292 238 123 VCU12MSLF 345 238 123 VCU17MSLF 438 238 123 R RC CD D  IIn ncco om meerr List No A B C VCU2MRCD 126 210 96 VCU5MRCD 188 238 123 VCU8MRCD 241 238 123 VCU11MRCD 292 238 123 VCU14MRCD 345 238 123 VCU19MRCD 438 238 123 D Du uaall  R RC CD D List No A B C VCU26 345 238 123 VCU27 438 238 123 H Hiiggh h  IIn ntteeggrriittyy List No A B C VCU41 345 238 123 VCU42 345 238 123 VCU43 438 238 123 VCU44 438 238 123 VCU45 438 238 123 DIMENSIONS MCBs British Standards  BS EN 60898: 1991 Rated Voltage 240 Volts Tripping characteristics Type B Short circuit rating 6kA Reference calibration temperature 30˚C RCBOs British Standards  BSEN 61009 Rated Voltage 230 Volts SP or SP with switched neutral Tripping characteristics Type C Short circuit rating 6kA Reference calibration temperature 30˚C Rated residual operating current  30mA A C B A C B 2009 Volex 76pp  4/9/08  03:17  Page 69

Index 70 CA1075 10 CA1076 10 CA2001 10 CA2001L 10 MC1020 53 MC1030 53 MC1040 53 MC1050 53 MC1054 53 MC1060 53 MC1070 53 MC1080 53 MC1081 53 MC1092 53 MC1108 53 MC1208 53 MC1300 53 MC1500 53 MC9100 53 MC9200 53 MC9702 53 MC9901 53 MC9974 53 MC9984 53 MC9992 53 MC9993 53 V1500_ _ 30 VB0250_ _PU 41 VB0252_ _PU 41 VB0400_ _PU 41 VB06 62 VB10 62 VB1020_ _ 41 VB1030_ _ 41 VB1040_ _ 41 VB1050_ _ 41 VB1054_ _ 41 VB1060_ _ 42 VB1080_ _ 43 VB1081_ _ 43 VB1300_ _ 42 VB1500_ _  42 VB16 62 VB20 62 VB32 62 VB40 62 VB50 62 VB9702_ _ 42 VB9991_ _ 43 VB9996_ _ 43 VBL 62 VBLPP 62 VCGKIT 59 VCU11MMS 60 VCU11MRCD 61 VCU11MS 58 VCU11RCD 59 VCU12MSLF 60 VCU12SLF 58 VCU14MMS 60 VCU14MRCD 61 VCU14MS 58 VCU14RCD 59 VCU16 58 VCU17 58 VCU17MSLF 60 VCU17SLF 58 VCU18MRCD 61 VCU19MMS 60 VCU19MS 58 VCU19RCD 59 VCU26 60 VCU27 60 VCU2MMS 60 VCU2MRCD 61 VCU2MS 58 VCU2RCD 59 VCU31 58 VCU32 58 VCU33 58 VCU34 58 VCU35 58 VCU41 60 VCU42 60 VCU43 60 VCU44 60 VCU45 60 VCU5MMS 60 VCU5MRCD 61 VCU5MS 58 VCU5RCD 59 VCU6MSLF 60 VCU6SLF 58 VCU8MMS 60 VCU8MRCD 61 VCU8MS 58 VCU8RCD 59 VCU9MSLF 60 VCU9SLF 58 VCUBLPP 62 VCUSHOWERKIT 59 VG3201SG 27 VG3203SG 27 VG3206SG 27 VG3209SG 27 VG3430 26 VG3435 26 VG3436 26 VG3450 26 VG3451 26 VG3460 26 VG3460BO 26 VG3460DW 26 VG3460EF 26 VG3460FF 26 VG3460FR 26 VG3460FZ 26 VG3460HB 26 VG3460HD 26 VG3461 26 VG3461ELT 26 VG3469 26 VG3489 26 VG3490 26 VG3490/1 26 VG3491 26 VG3492 26 VG3493 26 VG3494 26 VG3530 26 VG3535 26 VG3550 26 VG3551 26 VG3552 26 VG3570_ _ 27 VG3570WH 27 VG3571 27 VG3571_ _ 27 VG3572 27 VG3572_ _ 27 VG3573 27 VG3573_ _ 27 VG3574 27 VG3574_ _ 27 VG3576 27 VG3576_ _ 27 VG3578_ _ 27 VG3578WH 27 VG3579_ _ 27 VG3581SG 27 VG3582SG 27 VG3583SG 27 VG3584SG 27 VG3586SG 27 VG3588SG 27 VG3901 26 VG3902 26 VG3903 26 VG3904 26 VG3940 26 VR25 62 VR40 62 VR63 62 VR80 62 VRCBO06/1 62 VRCBO0630 62 VRCBO10/1 62 VRCBO1030 62 VRCBO16/1 62 VRCBO1630 62 VRCBO20/1 62 VRCBO2030 62 VRCBO32/1 62 VRCBO3230 62 VRCBO40/1 62 VRCBO4030 62 VRE2 62 VT1092 8, 55 VT1092SG 46, 55 VT1108 8, 55 VT1108SG 46, 55 VT1208 8, 55 VT1208SG 46, 55 VT1507 8 VT1951 55 VT1952 55 VT7066 12 VX0009 21 VX0010 21 VX0011 21 VX0018 21 VX0030 13 VX0042 13 VX0205 20 VX0205HO 20 VX0208HO 20 VX0218HO 20 VX0250_ _PU 29 VX0250LV 5 VX0250PSPU 32 VX0250PU 5 VX0250SBPU 32 VX0250SSPU 32 VX0252_ _PU 29 VX0252APCPU 33 VX0252LV 5 VX0252LV_ _ 29 VX0252LVAPC 33 VX0252LVRBB 33 VX0252LVRBN 33 VX0252PSPU 32 VX0252PU 5 VX0252RBBPU 33 VX0252SBPU 32 VX0252SSPU 32 VX0253_ _PU 29 VX0253APCPU 33 VX0253LV_ _ 29 VX0253LVAPC 33 VX0253LVRBB 33 VX0253LVRBN 33 VX0253RBBPU 33 VX0254_ _PU 29 VX0254APCPU 33 VX0254RBBPU 33 VX0254RBNPU 33 VX0400_ _PU 29 VX0400APCPU 33 VX0400LV 5 VX0400LV_ _ 29 VX0400LVAPC 33 VX0400LVRBB 33 VX0400LVRBN 33 VX0400PSPU 32 VX0400PU 5 VX0400RBBPU 33 VX0400SBPU 32 VX0400SSPU 32 VX0400TRD_ _ 29 VX0400TRDAPC 33 VX0400TRDRBB 33 VX0400TRDRBN 33 VX0402_ _PU 29 VX0402LV 5 VX0402PU 5 VX0500TD_ _ 29 VX0500TDAPC 33 VX0500TDRBB 33 VX0500TDRBN 33 VX0580 13 VX0850 19 VX0851 19 VX1/T2 20 VX1/T2HO 20 VX1000 4 VX1000/LP 4 VX1000/P 4 VX1010 4 VX1010_ _ 29 VX1010PS 32 VX1010SB 32 VX1010SG 45 VX1010SS 32 VX1013 9 VX1013_ _ 29 VX1013APC 33 VX1013PS 32 VX1013RBB 33 VX1013RBN 33 VX1013SB 32 VX1013SS 32 VX1020 4 VX1020_ _ 29 VX1020APC 33 VX1020PS 32 VX1020RBB 33 VX1020RBN 33 VX1020SB 32 VX1020SG 45 VX1020SS 32 VX1030 4 VX1030_ _ 29 VX1030APC 33 VX1030PS 32 VX1030RBB 33 VX1030RBN 33 VX1030SB 32 VX1030SG 45 VX1030SS 32 VX1040 4 VX1040_ _ 29 VX1040APC 33 VX1040PS 32 VX1040RBB 33 VX1040RBN 33 LIST NO PAGE NO LIST NO PAGE NO LIST NO PAGE NO LIST NO PAGE NO LIST NO PAGE NO 2009 Volex 76pp  4/9/08  03:17  Page 70

Index 71 VX1040SB 32 VX1040SG 45 VX1040SS 32 VX1050 4 VX1050_ _ 29 VX1050APC 33 VX1050PS 32 VX1050RBB 33 VX1050RBN 33 VX1050SB 32 VX1050SG 45 VX1050SS 32 VX1054 4 VX1054_ _ 29 VX1054APC 33 VX1054PS 32 VX1054RBB 33 VX1054RBN 33 VX1054SB 32 VX1054SG 45 VX1054SS 32 VX1060 10 VX1060_ _ 29 VX1060APC 33 VX1060F_ _ 29 VX1060FSG 45 VX1060PS 32 VX1060RBB 33 VX1060RBN 33 VX1060SB 32 VX1060SG 45 VX1060SS 32 VX1060WH 10 VX1060WH_ _ 29 VX1060WHF_ _ 29 VX1070 10 VX1070_ _ 29 VX1070F__ 29 VX1070FSG 45 VX1070PS 32 VX1070SB 32 VX1070SG 45 VX1070SS 32 VX1070WH 10 VX1080 9 VX1080_ _ 30 VX1080F_ _ 30 VX1080PS 32 VX1080RBB 33 VX1080RBN 33 VX1080SB 32 VX1080SG 47 VX1080SG/F 47 VX1080SS 32 VX1081 9 VX1081_ _ 30 VX1081APC 33 VX1081F_ _ 30 VX1081PS 32 VX1081RBB 33 VX1081RBN 33 VX1081SB 32 VX1081SG 47 VX1081SG/F 47 VX1081SS 32 VX1090 9 VX1090_ _ 30 VX1090APC 33 VX1090F_ _ 30 VX1090FSG 47 VX1090PS 32 VX1090RBB 33 VX1090RBN 33 VX1090SB 32 VX1090SG 47 VX1090SS 32 VX1091 9 VX1091FSG 47 VX1091SG 47 VX1098APC 33 VX1120_ _ 29 VX1120APC 33 VX1120RBB 33 VX1120RBN 33 VX1130_ _ 29 VX1130APC 33 VX1130RBB 33 VX1130RBN 33 VX1140_ _ 29 VX1140APC 33 VX1140RBB 33 VX1140RBN 33 VX1150_ _ 29 VX1150APC 33 VX1150RBB 33 VX1150RBN 33 VX1300 8 VX1300_ _ 30 VX1300/D 8 VX1300/D_ _ 30 VX1300APC/ 33 VX1300PS 32 VX1300PS/D 32 VX1300RBB/D 33 VX1300RBN/D 33 VX1300SB 32 VX1300SB/D 32 VX1300SG 46 VX1300SS 32 VX1300SS/D 32 VX1302 13 VX1307 13 VX1307BK 13 VX1390 13 VX1400 8 VX1400_ _ 30 VX1400SG 46 VX1500 8 VX1500/D 8, 30 VX1500APC/D 33 VX1500PS 32 VX1500PS/D 32 VX1500RBB/D 33 VX1500RBN/D 33 VX1500SB 32 VX1500SB/D 32 VX1500SG 46 VX1500SS 32 VX1500SS/ 32 VX1590WH 8 VX1600 8 VX1600_ _ 30 VX1600SG 46 VX1700 8 VX1800 8 VX1904 9 VX1906 9 VX1907 9 VX20/2 21 VX2060 4 VX2061 4 VX2062 4 VX3005TDBB 39 VX3005TDBN 35, 39 VX3005TDD 38 VX3005TDPB 38 VX3005TDPS 38 VX3010_ _ 35 VX3013_ _ 36 VX3013BB 39 VX3013BN 39 VX3013PB 39 VX3013PS 38 VX3020_ _ 35 VX3020BB 39 VX3020BN 39 VX3020PB 39 VX3020PS 38 VX3020SS 38 VX3030_ _ 35 VX3030BB 39 VX3030BN 39 VX3030PB 39 VX3030PS 38 VX3030SS 38 VX3031SS 38 VX3040_ _ 35 VX3040BB 39 VX3040BN 39 VX3040PB 39 VX3040PS 38 VX3040SS 38 VX3050_ _ 35 VX3050BB 39 VX3050BN 39 VX3050PB 39 VX3050PS 38 VX3050SS 38 VX3054_ _ 35 VX3054BB 39 VX3054BN 39 VX3054PB 39 VX3054PS 38 VX3054SS 38 VX3060_ _ 36 VX3060BB 39 VX3060BN 39 VX3060PB 39 VX3060PS 38 VX3060SS 38 VX3061_ _ 37 VX3061BB 16, 39 VX3061BN 16, 39 VX3061PB 39 VX3061PBWH 16 VX3061PS 16, 38 VX3061SS 16, 38 VX3062_ _ 37 VX3062BB 16, 39 VX3062BN 16, 39 VX3062PB 39 VX3062PBWH 16 VX3062PS 16, 38 VX3062SS 16, 38 VX3080_ _ 35 VX3080BB 39 VX3080BN 39 VX3080PB 39 VX3080PS 38 VX3080SS 38 VX3081_ _ 35 VX3081BB 39 VX3081BN 39 VX3081PB 39 VX3081PS 38 VX3081SS 38 VX3090_ _ 35 VX3090BB 39 VX3090BN 39 VX3090PB 39 VX3090PS 38 VX3090SS 38 VX3120_ _ 35 VX3120BB 39 VX3120BN 39 VX3120PB 39 VX3120PS 38 VX3120SS 38 VX3130_ _ 35 VX3130BB 39 VX3130BN 39 VX3130P 38 VX3130PB 39 VX3130SS 38 VX3140_ _ 35 VX3140BB 39 VX3140BN 39 VX3140PB 39 VX3140PS 38 VX3140SS 38 VX3150_ _ 35 VX3150BB 39 VX3150BN 39 VX3150PB 39 VX3150PS 38 VX3150SS 38 VX3252_ _PU 35 VX3252BBPU 39 VX3252BNPU 39 VX3252LV_ _ 35 VX3252LVBB 39 VX3252LVBN 39 VX3252LVPB 39 VX3252LVPS 38 VX3252LVSS 38 VX3252PBPU 39 VX3252PSPU 38 VX3252SSPU 38 VX3253_ _PU 35 VX3253BBPU 39 VX3253BNPU 39 VX3253LV_ _ 35 VX3253LVBB 39 VX3253LVBN 39 VX3253LVPB 39 VX3253LVPS 38 VX3253LVSS 38 VX3253PBPU 39 VX3253PSPU 38 VX3253SSPU 38 VX3254_ _PU 35 VX3254BBPU 39 VX3254BNPU 39 VX3254PSPU 38 VX3254SSPU 38 VX3300_ _/D 35 VX3300BB/D 39 VX3300BN/D 39 VX3300PB/D 39 VX3300PS/D 38 VX3300SS/D 38 VX3400_ _PU 35 VX3400BBPU 39 VX3400BNPU 39 VX3400LV_ _ 35 VX3400LVBB 39 VX3400LVBN 39 VX3400LVPB 39 VX3400LVPS 38 VX3400LVSS 38 VX3400PBPU 39 VX3400PSPU 38 VX3400SSPU 38 VX3400TRDBB 39 VX3400TRDBN 35, 39 LIST NO PAGE NO LIST NO PAGE NO LIST NO PAGE NO LIST NO PAGE NO LIST NO PAGE NO 2009 Volex 76pp  4/9/08  03:17  Page 71

Index 72 VX3400TRDPB 39 VX3400TRDPS 38 VX3400TRDSS 38 VX3500_ _/D 35 VX3500BB/D 39 VX3500BN/D 39 VX3500PB/D 39 VX3500PS/D 38 VX3500SS/D 38 VX3700_ _ 36 VX3700BB 39 VX3700BN 39 VX3700PB 39 VX3700PS 38 VX3700SS 38 VX3703_ _ 36 VX3703BB 39 VX3703BN 39 VX3703PB 39 VX3703PS 38 VX3703SS 38 VX3712_ _ 36 VX3713BB 39 VX3713BN 39 VX3713P 38 VX3713PB 39 VX3713SS 38 VX3800_ _ 37 VX3800BB 39 VX3800BN 39 VX3800PB 39 VX3800PS 38 VX3800SS 38 VX3905_ _ 35 VX3905BB 39 VX3905BN 39 VX3905PB 39 VX3905PS 38 VX3905SS 38 VX3974_ _ 37 VX3974BB 39 VX3974BN 39 VX3974PB 39 VX3974PS 38 VX3974SS 38 VX3984_ _ 37 VX3984BB 39 VX3984BN 39 VX3984PB 39 VX3984PS 38 VX3984SS 38 VX3991_ _ 37 VX3991BB 39 VX3991BN 39 VX3991PB 39 VX3991PS 38 VX3991SS 38 VX3992_ _ 37 VX3992BB 39 VX3992BN 39 VX3992PB 39 VX3992PS 38 VX3992SS 38 VX3993_ _ 37 VX3993BB 39 VX3993BN 39 VX3993PB 39 VX3993PS 38 VX3993SS 38 VX3996_ _ 37 VX3996BB 39 VX3996N 39 VX3996PB 39 VX3996PS 38 VX3996SS 38 VX4000 4 VX4020 4 VX4030 4 VX4040 4 VX4522 20 VX5001 51 VX5002 51 VX5003 51 VX5004 51 VX5020 50 VX5030 50 VX5040 50 VX5050 50 VX5073 51 VX5080 50 VX5090 50 VX5100 50 VX5123 51 VX5180 51 VX5200 50 VX5207 10 VX5208 10 VX5270 51 VX5300 50 VX6080 17 VX6080BK 17 VX6081 17 VX6081BK 17 VX6082 17 VX6677 19 VX6678 19 VX6681 19 VX6850 19 VX9001 5, 21 VX9002 5, 21 VX9009 5 VX9023 21 VX9023BK 21 VX9029 21 VX9029BK 21 VX9061_ _ 31 VX9061APC 16, 33 VX9061RBB 16, 33 VX9061RBBN 33 VX9061RBN 16 VX9062 16 VX9062_ _ 31 VX9062APC 16 VX9062PC 33 VX9062PS 16, 33 VX9062RBB 16, 33 VX9062RBBN 33 VX9062RBN 16 VX9062SB 32 VX9062SS 16, 33 VX9064 16 VX9064_ _ 31 VX9064PS 16 VX9064SB 32 VX9064SS 16, 32 VX906PS 32 VX9074 20 VX9100 8 VX9100_ _ 30 VX9100SG 46 VX9143 23 VX9200 8 VX9200_ _ 30 VX9200SG 46 VX9215 19 VX9215HO 19 VX9230 8 VX9401 23 VX9402 23 VX9403 23 VX9404 23 VX9405 23 VX9406 23 VX9409 23 VX9410 23 VX9412 23 VX9414 23 VX9415 23 VX9416 23 VX9417 23 VX9700 11 VX9700_ _ 30 VX9700APC 33 VX9700PS 32 VX9700RBB 33 VX9700RBN 33 VX9700SB 32 VX9700SS 32 VX9701 11 VX9701_ _ 30 VX9702 11 VX9702_ _ 30 VX9702SG 47 VX9703 11 VX9703_ _ 30 VX9703APC 33 VX9703PS 32 VX9703RBB 33 VX9703RBN 33 VX9703SB 32 VX9703SG 47 VX9703SS 32 VX9704 11 VX9706 12 VX9706 21 VX9712 11 VX9712APC 33 VX9712RBB 33 VX9712RBN 33 VX9713 11 VX9713_ _ 30 VX9713PS 32 VX9713SB 32 VX9713SS 32 VX9800 12 VX9800_ _ 31 VX9800APC 33 VX9800PS 32 VX9800RBB 33 VX9800RBN 33 VX9800SB 32 VX9800SS 32 VX9900 9 VX9900_ _ 30 VX9900SG 46 VX9901 9 VX9901_ _ 30 VX9905_ _ 30 VX9905APC 33 VX9905PS 32 VX9905RBB 33 VX9905RBN 33 VX9905SS 32 VX993RBB 33 VX9969 17 VX9970 17 VX9972 17 VX9973 17 VX9974 15 VX9974_ _ 31 VX9974APC 33 VX9974PS 32 VX9974RBB 33 VX9974RBN 33 VX9974SB 32 VX9974SS 32 VX9976 17 VX9976BK 17 VX9977 17 VX9978 17 VX9978BK 17 VX9979 17 VX9979BK 17 VX9980 17 VX9980BK 17 VX9981 17 VX9981BK 17 VX9982 15 VX9984 15 VX9984_ _ 31 VX9984APC 33 VX9984PS 32 VX9984RBB 33 VX9984RBN 33 VX9984SL 32 VX9984SS 32 VX9986 15 VX9987 17 VX9987BK 17 VX9988 17 VX9988BK 17 VX9989 17 VX9989BK 17 VX9990 12 VX9991 13 VX9991_ _ 31 VX9991APC 33 VX9991PS 32 VX9991RBB 33 VX9991RBN 33 VX9991SB 32 VX9991SG 47 VX9991SS 32 VX9992 15 VX9992_ _ 31 VX9992APC 33 VX9992PS 32 VX9992RBB 33 VX9992RBN 33 VX9992SB 32 VX9992SS 32 VX9993 15 VX9993_ _ 31 VX9993APC 33 VX9993PS 32 VX9993RBN 33 VX9993SB 32 VX9993SS 32 VX9996 13 VX9996_ _ 31 VX9996APC 33 VX9996PS 32 VX9996RBB 33 VX9996RBN 33 VX9996SB 32 VX9996SG 47 VX9996SS 32 LIST NO PAGE NO LIST NO PAGE NO LIST NO PAGE NO LIST NO PAGE NO LIST NO PAGE NO 2009 Volex 76pp  4/9/08  03:17  Page 72

Electrium Sales Ltd. T erms & Conditions 73 HOME 1 Contract Terms Quotations & Orders 1.1 Unless other terms and conditions are expressly accepted by Electrium by means of a specific written amendment heretosigned by Electrium or a Director of Electrium the contract willbe on the terms and conditions set out below (“the ContractTerms”) to the exclusion of any other terms and conditions(except those implied in favour of a seller which are not incon-sistent with the Contract Terms) whether or not the same areendorsed upon, delivered with or referred to in any purchaseorder or other document delivered or sent by the Customer toElectrium or by Electrium to the Buyer reference made byElectrium to the Customer’s order, specification or like docu-ment will not be deemed to imply that any terms or conditionsendorsed upon, delivered with or referred to in such order,specification or like document will have effect to the exclusionor amendment of the Contract Terms. No variation, addition ormodification of the Contract Terms conditions shall be bindingon Electrium unless such variation, addition or modification beagreed to in writing under the signature of a Director ofElectrium. 1.2 Any quotation is given on the basis that no contract will come into existence until the Customer places an order pursuantthereto. Any quotation is valid for a period of 30 days only fromits date provided that Electrium has not previously withdrawn it. 2 Price The price of Goods supplied hereunder (“the Goods”) is exclusive ofVAT or any successor tax thereto unless otherwise agreed in writing.The price for the Goods shall be (unless otherwise agreed byElectrium in writing) the list price of Electrium current at the date ofdespatch and in the case of an order for delivery by instalments theprice payable for each instalment shall be Electrium’s list price cur-rent at the date of despatch for each instalment. All prices are basedon standard pack sizes and quantities and Electrium reserves theright to levy an additional charge if such packs must be broken up tofulfil an order.The price of Goods is inclusive of costs of carriage tothe Customer’s premises in Great Britain and Northern Irelandexcept on individual orders having a net value calculated by referenceto the Company’s most recent price list of less than £200 (excludingVAT) which shall be subject to an additional charge of not less than£15.00 (excluding VAT) to cover carriage and packing.The price ofGoods is based on the costs of materials, labour, sub-contracts, trans-port, taxes, duties and currency exchange rates ruling at the date ofthe quotation. Electrium reserves the right to amend the contractprice to take account of any variations in these costs or the imposi-tion of any new taxes or duties occurring from whatever causebefore delivery of the Goods. 3 Payment The due date for payment shall be the last day of the month follow-ing the month of despatch of Goods supplied by Electrium. Paymentmade before the due date for payment shall be subject to a settle-ment discount of 2.5%.VAT is calculated on the discounted value ofthe invoice and is not subject to settlement discount. Interest at anannual rate of 3% per month will accrue daily and be calculated on adaily basis on overdue accounts from the date of invoice until pay-ment. Notwithstanding any Contract Term allowing the Customercredit payment shall become due and payable to Electrium immedi-ately upon the termination of the contract.The Customer shall notbe entitled to exercise any right of set-off or lien or any similar rightor claim in connection with the Goods or the price payable therefor. 4 Packing Materials Packing cases and cartons will be provided free of charge byElectrium. All pallets used shall remain at all times the property ofElectrium and are to be returned to Electrium on demand in goodcondition. Electrium reserves the right to alter the method of pack-ing without reference to the Customer. 5 Damage or Loss in Transit Electrium will not be liable in respect of any damage or discrepancy,shortage or loss in transit or any claim that the Goods delivered donot otherwise comply with the contract unless the Customer shallhave informed the Company in writing, telex or facsimile as follows:(a) Within three days of delivery in the event of any damage, dis-crepancy or shortage. (b) Within seven days of delivery in the event that the Goods donot comply with the contract, and(c) Within twenty-one days of receipt of the Company’s invoice inthe event of non-delivery. Where the Goods are accepted from the Company’s carriers theyshall be deemed to have been checked by the Purchaser and accept-ed unless the delivery receipt is signed and endorsed ‘unexamined’and the packing and its contents are retained for later inspection. 6 Delivery The place of delivery for Goods shall be the Customer’s premises oras otherwise agreed by Electrium in writing.The time of delivery willbe as agreed between the parties or if no such agreement has beenreached will be within a reasonable time and the Company will beentitled to make delivery by instalments. In no circumstances willElectrium be liable for loss or damage of any kind whatsoever causeddirectly or indirectly by any delay in the delivery of Goods, norunless such delay exceeds 180 days will any delay entitle theCustomer to terminate or rescind the contract. Notwithstanding anyother Contract Term, risk in the Goods shall pass to the Buyer whenthe Goods are delivered to the Customer or its agent. 7 Title of Goods Until Electrium has been paid in full for the Goods comprised in thisand/or any other contract between the Customer and Electrium, theCustomer shall hold the Goods in a fiduciary capacity as bailee forElectrium and:(i) the title to, ownership of, and the property in, the Goods shallremain vested in Electrium (notwithstanding delivery of thesame and parting of the risk therein to the Customer) until pay-ment in full for all Goods comprised in this and every othercontract between Electrium and the Customer has beenreceived by Electrium. (ii) The Customer shall be in possession of the Goods asElectrium’s bailee. If so required the Customer shall store theGoods for Electrium without charge to Electrium separate fromany goods which are the property of the Customer and/or anythird party and ensure that they are clearly marked and identi-fied as belonging to Electrium. (iii) Electrium reserves the right to require the Customer to return the Goods and may recover and sell the same at any time. Forthat purpose Electrium’s servants and agents together with all necessary and appropriate transport shall be entitled to unre-stricted access to the Customer’s premises and any other loca-tion where the Goods are situated to take possession of theGoods and, if necessary, dismantle the Goods from any articleor articles to which they may have been attached and toremove the Goods from the Customer’s premises. (iv) Prior to the property in the Goods passing to the Customer Electrium permits the Customer to deliver the Goods to athird party pursuant to a bona fide and arms-length agreementto re-sell the Goods and allows the Customer to convert orincorporate the Goods into or mix the Goods with othergoods but such liberty will cease upon the termination of thecontract. (v) Where Electrium is unable to determine whether any goods areElectrium’s Goods the Customer shall be deemed to have soldall goods of the kind sold by Electrium to the Customer in theorder in which they were invoiced to the Customer. 8 Descriptive Matter Descriptive matter, illustrations, dimensions and weights issued byElectrium are to be regarded as being for guidance only and cannotbe held as binding in any way. In pursuance of Electrium’s policy ofproduct improvement Electrium reserves the right to alter patternsand designs without prior notice. 9 Guarantee Electrium will make good by replacement (or its option by repair)defects which under proper use appear in the Goods within a periodof twelve calendar months after the Goods have been despatched,and which arise solely from faulty design, materials or workmanshipprovided always that defective Goods have been returned toElectrium and Electrium was notified of the defect or suspecteddefect immediately the same became known to the Customer.Thecost of carriage on such returned Goods and the cost of re-deliveryof the repaired or new Goods to be borne by Electrium. Save for theElectrium’s control equipment which has been correctly repaired ormodified by the use of standard parts supplied by Electrium for suchpurpose, Electrium excludes all liability in respect of any Goodswhich have been re-finished and dismantled or altered in any way orif the Goods were improperly installed or connected or if theCustomer fails to observe or perform the requirements of any main-tenance procedures relating to the Goods. Any Goods replaced willbelong to Electrium. Any repaired or replacement Goods will beguaranteed on these terms for the unexpired portion of the twelvemonth period. In addition, the obligations of Electrium under thiscondition will not apply if the Customer is in breach of this or anyother contract with Electrium. Subject to this condition, all condi-tions, warranties and representations, whether express or implied (bystatute or otherwise) relating to the Goods are hereby excludedinsofar as the same can be excluded without such exclusion beingvoid or unenforceable.Electrium will be under no liability under the contract for any per-sonal injury, death, loss or damage of any kind whatsoever (otherthan death or personal injury resulting from Electrium’s negligence)whether consequential or otherwise including but not limited to lossof profits and Electrium hereby excludes all conditions, warrantiesand stipulations express or implied, statutory, customary or other-wise which but for such exclusion would or might subsist in favourof the Customer except that such exclusion will not apply to anyimplied condition that Electrium has or will have the right to sell theGoods when the property is to pass; or when Electrium deals as aconsumer (as defined in section 12 of the Unfair Contract Terms Act1977), any implied term relating to the conformity of the Goods withtheir description or sample or as to their quality or fitness for a par-ticular purpose. In no circumstances will Electrium or its employees,agents or sub-contractors be liable for any loss or damage of anykind whatsoever (other than death or personal injury resulting fromElectrium’s negligence) whether consequential or otherwise causeddirectly or indirectly by any negligence or other tortious act orbreach of statutory duty on the part of Electrium or on the part ofany of its employees, agents or sub-contractors in connection withor arising out of the manufacture or supply of the Goods or in con-nection with any statement given or made (or advice not given ormade) by or on behalf of Electrium. 10 Patents Electrium will indemnify the Customer against any claim of infringe-ment of letters patent, registered design, trademark or copyright(existing at the date of the contract) arising from the use or sale ofany article or materials supplied by Electrium to the Customer andagainst all costs and damages which the Customer may incur in anyaction for such infringement or for which the Customer maybecome liable in any such action provided always that this indemnityshall not apply to any infringement which arises in connection withany design or instruction issued or given by the Customer toElectrium or to the use of such article or material in a manner orfor a purpose outside the UK or to any infringement which is due tothe use of such article or material in association or combination withany other article or material not supplied by Electrium and providedalso that this indemnity is conditional on the Customer making noadmission in respect of such alleged infringement and givingElectrium the earliest possible notice in writing of any claim beingmade or action threatened or brought against the Customer and onthe Customer permitting Electrium at Electrium’s expense to con-duct any litigation that may ensue and all negotiations for the settle-ment of a claim.The Customer warrants that any design or instruction issued orgiven by the Customer shall not be such as will cause Electrium toinfringe any letters patent, registered design, trademark or copyrightin the execution of the Customer’s order and the Customer agreesto indemnify and keep Electrium indemnified against all liability in theevent that such warrant is found to be untrue, misleading or breached. 11 Advice Advice which Electrium or its agents may give to the Customer shallbe given in good faith but Electrium shall not be liable for any loss ordamage arising directly or indirectly therefrom or attributable there-to unless contained in any written representation or statementissued directly by Electrium. 12 Safety The Customer shall ensure that any modifications whatsoever madeto the Goods supplied hereunder comply with the requirements ofany applicable Safety Regulations. Plugs supplied hereunder shall beso connected as to ensure that they are safe and in full compliancewith any applicable Safety Regulations. The Customer shall ensurethat any kits supplied hereunder are so assembled as to ensure thatthe assembled product is safe and complies with the requirements ofany applicable Safety Regulations.Without prejudice to the aboveprovisions, where Electrium provides the Customer with information about the use for which Goods are designed and have been testedand about any conditions to ensure that when put to that use theywould be safe and without risk to health, the Customer shall use theGoods accordingly and comply with the said conditions.To be prop-erly used the Goods shall be selected, installed, commissioned andmaintained in accordance with good engineering practice and underthe supervision of suitably qualified personnel. 13 Statutory and other Regulations If the cost to Electrium of performing its obligations under any con-tract shall be increased or reduced by reason of making or amend-ment after the date of its quotation of any law or of any other order,regulation or bye-law having the force of law that shall affect the per-formance of Electrium’s contractual obligations, the amount of suchincrease or reduction shall be added to or deducted from the con-tract price as the case may be. 14 Cancellation If the Customer cancels, extends or delays or purports to cancel,extend or delay the contract or part thereof, or fails to take deliveryof any Goods at the time agreed (if any) or if no time is agreed with-in a reasonable time, then the Customer will be liable (without preju-dice to any other rights of Electrium to claim damages) to indemnifyand keep indemnified Electrium against any resulting loss, damage orexpense incurred by Electrium in connection with the supply or non-supply of the Goods including the cost of any material, used orintended to be used therefor and the cost of labour and other over-heads including a percentage in respect of profit. If Electrium isunable (whether temporarily or permanently) to procure any servic-es or goods necessary to enable it to supply the Goods or if thesupply of the Goods is prevented or hindered by reason of any causebeyond Electrium’s reasonable control which for the avoidance ofdoubt and without prejudice to the generality of the foregoing shallinclude governmental action, war, riot, civil commotion, fire, flood,epidemic, labour disputes including labour disputes involving thework force or any part thereof of Electrium, restraints or delaysaffecting shipping or carriers, currency restrictions and Act of God,Electrium may cancel the contract by notice in writing to theCustomer so far as it relates to Goods not then supplied or worknot then done and such cancellation shall not give rise to any claimsby the Customer provided that the Customer shall remain liable topay for Goods delivered prior to the date of such cancellation. 15 General (a) The headings herein are inserted for convenience only and shallnot affect the interpretation of the Contract Terms. (b) Should any clause contained in the Contract Terms be held tobe invalid such invalidity will not affect the validity of theremaining clauses. (c) Any dispute arising out of this contract or the Contract Termsshall be referred in writing to an independent arbitrator whoshall be appointed by agreement between Electrium and theCustomer or in default of agreement by the President for thetime being of the Institute of Electrical Engineers whose deci-sion shall be binding on both parties. (d) The formation, interpretation and operation of the contract willbe subject to English Law and the Customer submits himself tothe non-exclusive jurisdiction of the English Courts. (e) Electrium will be entitled to assign sub-contract or sub-let thecontract or any part thereof. (f) Failure by Electrium to enforce any  of the Contract Terms will not be construed as a waiver of any of its rights here-under. EXPORT All Contract Terms set out above apply to overseas transactions (iesales outside the United Kingdom), where appropriate, except thefollowing:1.2 Any quotation is given on the basis that no contract will come into existence until Electrium despatches an acknowledgementof order to the Customer. Any quotation is valid for a period of 30 days only from its date provided that Electrium has notpreviously withdrawn it. 2 Price The price of Goods includes the cost of packing for shipment FOBBritish Port or Airport except that orders having a net value of £500and below shall be subject to an additional charge to cover packingand carriage. No allowance will be made in lieu of transportation ifthe Customer accepts delivery at the factory, container depot or atany other inland destination or provides his own transportation orwhere packing of a lesser standard is required. 3 Payment First orders from overseas Customers should be accompanied bybank references to enable payment terms to be agreed. Unless oth-erwise agreed in writing, payment is due on delivery. Goods shall bedeemed to have been delivered when the invoice has been presentedin the United Kingdom accompanied by the appropriate documentsof title. 16 Others The Goods will be sold FOB British Port or Airport and the Sellerwill be under no obligation to give the Buyer notice as specified inSection 32(3) of the Sale of Goods Act 1979. CIF or C & F arrange-ments can be made if requested by the Customer, at cost, andElectrium will, on receipt of Customer’s indemnity, take all reasonablesteps to recover from the Underwriters any loss or damage forwhich they may be liable.The Customer shall be solely responsible for complying with all legis-lation and regulations governing the importation of the Goods intothe country of destination including import and export licences andthe payment of duties thereon including but not limited to customsduties and VAT.The Customer shall indemnify Electrium against allcosts claims and demands arising out of any breach by the Customerof this Agreement. CONDITIONS OF USEThe products listed in this publication should be installed by suitablyqualified personnel in accordance with the requirements of relevantlegislation, regulations (including the IEE Wiring Regulations) and theaccepted practice in the industry. Any further information which maybe required about the use for which any specific product has beendesigned and tested, or about conditions of use, is available onrequest. In pursuance of our policy of continuing product improve-ment, equipment described in this publication is subject to changewithout notification. Covers  4/9/08  03:29  Page 2

2009 wiring accessories domestic circuit protection ELECTRIUM SALES LIMITED  A SIEMENS COMPANY EXPORT SALES Commercial Centre, Lakeside Plaza, Walkmill Lane, Bridgtown, Telephone: +44 1543 455049  Facsimile: +44 1543 455048   Cannock WS11  0XE. eMail: [email protected] eMail: [email protected]  Web: www.electrium.co.uk TECHNICAL DUBLIN OFFICE Telephone: 01543 438330  Facsimile: 01543 438321 Telephone: +353 1 4513303  Facsimile:+353 1 4513242 eMail: [email protected] UK SALES  DUBAI OFFICE  Telephone: 01543 455030   Facsimile: 01543 455031 Telephone: +971 4 3660395  Facsimile:+971 4 3660019 eMail: [email protected] Although every effort has been made to ensure accuracy in the compilation of the technical detail within this publication, specifications and performance data are constantly changing. Latest details can be obtained from Volex. Publication No.V2022 Printed in England. Covers  4/9/08  03:29  Page 1