Distributor Selection

Select the distributor you would like to use for your shopping cart.

Distributor

Gewiss UK - Product Catalogue - Power Short Form brochure 2015
Gewiss

Gewiss UK - Product Catalogue - Power Short Form brochure 2015

The technologically advanced range of modular and moulded-case devices joins the vast range of distribution boards and cabinets, enclosures and combined boards to create the GEWISS Protection System.

POWER 2015 PROTECTION SYSTEMS

GEWISS is an international leader in the production of systems and components  for low voltage electrical installations. The fact that development is seen as  a constant management feature has permitted GEWISS to assert itself as a  reference interlocutor for the electrotechnical market in the creation of solutions  for domotics, energy and the lighting industry. It is now present in Italy, France,  Germany, the United Kingdom, Spain, Portugal, China, Russia, Turkey, Romania,  Chile, the United Arab Emirates, and in a further 80 countries around the world. The technologically advanced range of modular and moulded-case devices joins the vast range of distribution boards and cabinets, enclosures and combined boards to create the GEWISS Protection System. Power GEWISS GROUP Discover the complete range at www.gewiss.com Domotics The domotic systems offer cutting-edge solutions for smart home and building management and control, guaranteeing safety, comfort and energy savings along with Italian design. Lighting Lighting systems designed for every room, area and location. Solutions that embrace LED technology to meet the requirements of industrial and commercial sector contexts, sport facilities and emergency lighting. Building Junction boxes and special containers, a complete and coordinated line of distribution boards, cutting-edge industrial connections and an integrated system of boards for special systems create the GEWISS distribution systems. 2

Gewiss Protection System 90 MCB range 90 RCD range 90 AM range 90 PV range 90 R e S taRt  range Protection   devices CVX 630K/630M  range CVX 160I/160E  range MTX/MSS range The GEWISS protection system is made up of products that work together perfectly, such as the innovative 90 R e S taRt  range (automatic reclosing devices), the 90 MCB and 90 RCD ranges (modular circuit breakers  for circuit and residual current protection), the MTX range (MCCBs for power distribution) and the 47 CVX range (metal distribution boards). An integrated selection of products to meet every possible need for the specific application - from residential to industrial - and to guarantee quality and safety in line with the market requisites. The GEWISS system offers a wealth of advantages: practical compatibility of homogeneous products, simple and quick system planning, installation and maintenance, modern and stylish design. 3

The only aut omatic  reclosing de vice   that tests the RC CB   without cutting off  the electricit y supply If the residual current device trips, R e S taRt  restores the  electricity supply quickly, but only after carrying out a system check (RD versions) and also a short-circuit check (RM version).Thanks to the innovative control logic, Autotest can regularly and automatically test the working of the residual current device without ever disconnecting the system from the power supply.PRO versions are available for continuous system monitoring: the system check is carried out at regular intervals until the fault clears and the device can be automatically and safely reclosed.The  R e S taRt  RM TOP version is also available. This allows you  to: -  establish the reclosing mode (with a system check, using  attempts, or remote) -  select the insulation threshold-  set the reclosing time delay R e S taRt  RD R e S taRt  RD PRO R e S taRt  RD PRO R e S taRt  RM PRO R e S taRt  RM R e S taRt  RM tOP R e S taRt  RM PRO R e S taRt  CM NOTE: R e S taRt  CM is a motor operating device without system check ReS tar t 2P r ange ReS tar t 4P r ange Automatic Reclosing  Devices R e S taRt   R e S taRt  with a utOteSt  2P R e S taRt  with a utOteSt  4P 4 90 R e S taRt   Range Automatic reclosing devices

R D R M PRO   version PRO   version PRO   version TOP   version Doesn't reclose in the event of a fault The user’s safety is guaranteed by the checking of the system  before reclosing. 3 3 3 3 3 3 3 ( ) Automatic test and no blackout during autotest The R e S taRt  AUTOTEST function carries out the RCCB intervention  test regularly and automatically, without disconnecting the system  from the power supply, thanks to a special bypass circuit. 3 3 Works without earth conductor R e S taRt  doesn't need earthing connection in order to work. 3 3 3 3 3 3 3 Protection in aggressive environments ReStart with AUTOTEST is recommended in difficult environments  where the regular, automatic AUTOTEST function keeps the RCCB in  good working order. 3 3 Continuous power supply for unattended systems  R e S taRt  PRO is recommended for unattended electrical systems  where a blackout could cause significant damage. 3 3 3 3 Continuous system monitoring Following a trip caused by a fault, R e S taRt  PRO repeats the check  every 2 minutes and only performs a reclosing once the fault has  disappeared. 3 3 3 3 ( ) Remote signalling with auxiliary contact An auxiliary contact allows remote signalling in the event of an  effective fault without reclosing. 3 3 3 3 3 BUS connection With the BUS interface module, R e S taRt  can be installed in  monitoring systems using the BUS RS485 communication protocol. 3 3 3 ( )   Quick reclosing R e S taRt  technology guarantees that the system check and  subsequent automatic reclosing are carried out quickly, to minimise  the time of out of service. 3 3 4P range 4P range   ( )  It's possible to choose the automatic reclosing mode:     - with a system check     - by attempts     - remote   ( )  It's possible to set the automatic reclosing time delay. ( )  For 4P versions only R e S taRt  RANGE   CHARACTERISTICS   AND ADVANTAGES sec. 10 5

R eStaRt  RANGE   MAIN TECHNICAL DATA  R D R M PRO   version PRO   version PRO   version TOP   version Circuit breaker type: SD SD MDC MT - MTC  MDC - MT+BD Number of poles: 2P 2P-4P 2P 2P - 4P 2P 1P+N - 2P - 4P 1P - 1P+N - 2P - 3P - 4P RCD type: A [IR] A[IR] A, A[IR] AC, A, A[IR], A[S] A, A[IR] AC, A, A[IR], A[S] AC, A, A[IR], A[S] No. of modules (circuit breaker included) 5 5 (2 poles) 7 (4 poles) 4 4 (2 poles) 3 (4 poles) 4 4 (2 poles) 3 (4 poles) 3 Residual operating   current IΔn: (mA) 30 30-300 30 30-100-300-500 30 30-300 30-100-300-500 Breaking capacity Icn: (kA) - - - - 4.5 - 6 4.5 - 6 - 10 4.5 ÷ 25 Rated current In: (A) 25 ÷ 63 25 ÷ 100 6 ÷ 32 1 ÷ 63 Coupled versions   with circuit breaker: 3 3 3 3  (2 poles) 3 3  (2 poles) Integrated   auxiliary contact: 3 3 3 3 3 Adjustable reclosing time: 3 Adjustable reclosing mode: 3 MT: MCB MTC:  compact MCB MDC:  compact RCBO SD: RCCB BD:  add-on RCD  Without circuit breakerNOTE: type A[IR] offers greater resistance to mains disturbance and atmospheric discharge compared with standard RCDs. Immunity level 8/20μs: 3000A for A[IR] version, 250A for standard version. R e S taRt  RANGE   MAIN TECHNICAL DATA  6 Automatic reclosing devices 90 R e S taRt   Range

Automatic reclosing devices with circuit safety check and automatic RCD test. RESTART WITH AUTOTEST DEVICES COUPLED WITH RCCBs 2 poles 4 poles 5 mod. 7 mod. IΔn = 30 mA IΔn = 30 mA IΔn = 300 mA In (A) A[IR] type A[IR] - PRO type A[IR] - PRO type 25 GW 90 901 N GW 90 911 GW 90 921 GW 90 927 40 GW 90 902 N GW 90 912 GW 90 922 GW 90 928 63 - GW 90 913 GW 90 923 GW 90 929 NOTE: ARD must be supplied with 230 V AC phase-neutral for working. Selection tables 7

Automatic reclosing devices with circuit safety check. RESTART RD DEVICES COUPLED WITH RCCBs SD 2 poles 2 poles - PRO version 4 poles - PRO version 4 mod. 4 mod. 6 mod. 7 mod. IΔn = 30 mA IΔn = 30 mA IΔn = 100 mA IΔn = 300 mA IΔn = 500 mA IΔn = 30 mA IΔn = 30 mA In (A) A type A[IR] type A type A[IR] type A type A type A[S] type A type AC type A type AC type A type 25 GW 94 817 R GW 95 651 R GW 94 817 P GW 95 651 P - GW 94 819 P - - GW 94 662 P GW 94 867 P - - 40 GW 94 827 R GW 95 656 R GW 94 827 P GW 95 656 P GW 94 828 P GW 94 829 P GW 94 924 P GW 94 830 P GW 94 667 P GW 94 897 P - - 63 GW 94 837 R GW 95 661 R GW 94 837 P GW 95 661 P GW 94 838 P GW 94 839 P GW 94 934 P GW 94 840 P - - GW 94 757 P GW 94 937 P NOTE: ARD must be supplied with 230 V AC phase-neutral for working. DEVICES TO BE COUPLED WITH RCCBs SD 4 POLES - PRO VERSION GW 90 966 GW 90 968 3 mod. 3 mod. + + RCCBs SD 4 POLES IΔn = 30 mA IΔn = 100 mA IΔn = 300 mA IΔn = 500 mA In (A) Type 3 mod. 4 mod. 3 mod. 4 mod. 3 mod. 4 mod. 3 mod. 4 mod. 25 AC GW 94 662 GW 94 697 - GW 94 698 GW 94 664 GW 94 699 - - GW 94 637 GW 94 639 A GW 94 867 GW 94 877 - GW 94 878 GW 94 869 GW 94 879 - - GW 94 552 GW 94 554 A[IR] - GW 95 676 - - - GW 95 678 - - 40 AC GW 94 667 GW 94 707 GW 94 668 GW 94 708 GW 94 669 GW 94 709 GW 94 670 GW 94 710 GW 94 647 GW 94 649 A GW 94 897 GW 94 927 GW 94 898 GW 94 928 GW 94 899 GW 94 929 GW 94 900 GW 94 930 GW 94 557 GW 94 559 A[IR] - GW 95 681 - - - GW 95 683 - - A[S] - - - - - GW 94 966 - - 63 AC - GW 94 757 - GW 94 758 - GW 94 759 - GW 94 760 GW 94 717 GW 94 719 A - GW 94 937 - GW 94 938 - GW 94 939 - GW 94 940 GW 94 907 GW 94 909 A[IR] - GW 95 686 - - - GW 95 688 - - A[S] - - - - - GW 94 976 - - 80 AC - GW 94 761 - GW 94 771 - GW 94 766 - - GW 94 727 GW 94 728 A - GW 94 947 - GW 94 948 - GW 94 949 - - A[IR] - - - - - GW 94 986 - - 100 AC - GW 94 777 - GW 94 778 - GW 94 779 - GW 94 780 GW 94 737 GW 94 739 A - GW 94 957 - GW 94 958 - GW 94 959 - GW 94 960 A[IR] - GW 95 696 - - - GW 95 698 - - A[S] - - - - - GW 94 996 - - NOTE: they are also compatible with 2-pole RCCBs (SD 2P). ARD must be supplied with 230 V AC phase-neutral for working. RCCBs with neutral on the left Selection tables 8 Automatic reclosing devices 90 R e S taRt   Range

Automatic reclosing devices with circuit safety and short-circuit check. RESTART RM DEVICES COUPLED WITH RCBOs MDC 2 poles 2 poles - PRO version 4 mod. 4 mod. IΔn = 30 mA IΔn = 30 mA IΔn = 300 mA Icn (A) Curve In (A) A type A[IR] type A type A type A[S] type 4500 C 6 GW 94 225 R - - - - 10 GW 94 226 R - - - - 13 GW 94 231 R - - - - 16 GW 94 227 R - - - - 20 GW 94 228 R - - - - 25 GW 94 229 R - - - - 32 GW 94 230 R - - - - 6000 C 6 GW 94 325 R GW 95 805 R GW 94 325 P GW 94 335 P - 10 GW 94 326 R GW 95 806 R GW 94 326 P GW 94 336 P - 13 GW 94 331 R GW 95 811 R GW 94 331 P - - 16 GW 94 327 R GW 95 807 R GW 94 327 P GW 94 337 P GW 95 847 P 20 GW 94 328 R GW 95 808 R GW 94 328 P GW 94 338 P GW 95 848 P 25 GW 94 329 R GW 95 809 R GW 94 329 P GW 94 339 P GW 95 849 P 32 GW 94 330 R GW 95 810 R GW 94 330 P GW 94 340 P GW 95 850 P NOTE: ARD must be supplied with 230 V AC phase-neutral for working. Selection tables DEVICES TO BE COUPLED WITH RCBOs 4 POLES - PRO VERSION GW 90 986 GW 90 988 3 mod. 3 mod. + + RCBO MDC 4P 4 mod. 4 mod. IΔn = 30 mA IΔn = 300 mA Icn (A) Curve In (A) AC type A type A[IR] type AC type A type A[S] type 4500 C 6 GW 94 065 GW 94 265 - GW 94 075 GW 94 275 - 10 GW 94 066 GW 94 266 - GW 94 076 GW 94 276 - 13 GW 94 071 GW 94 271 - - - - 16 GW 94 067 GW 94 267 - GW 94 077 GW 94 277 - 20 GW 94 068 GW 94 268 - GW 94 078 GW 94 278 - 25 GW 94 069 GW 94 269 - GW 94 079 GW 94 279 - 32 GW 94 070 GW 94 270 - GW 94 080 GW 94 280 - 6000 C 6 GW 94 165 GW 94 365 GW 95 815 GW 94 175 GW 94 375 - 10 GW 94 166 GW 94 366 GW 95 816 GW 94 176 GW 94 376 - 13 GW 94 171 GW 94 371 GW 95 821 - - - 16 GW 94 167 GW 94 367 GW 95 817 GW 94 177 GW 94 377 GW 95 857 20 GW 94 168 GW 94 368 GW 95 818 GW 94 178 GW 94 378 GW 95 858 25 GW 94 169 GW 94 369 GW 95 819 GW 94 179 GW 94 379 GW 95 859 32 GW 94 170 GW 94 370 GW 95 820 GW 94 180 GW 94 380 GW 95 860 B 6 - GW 95 165 - - GW 95 175 - 10 - GW 95 166 - - GW 95 176 - 13 - GW 95 171 - - - - 16 - GW 95 167 - - GW 95 177 - 20 - GW 95 168 - - GW 95 178 - 25 - GW 95 169 - - GW 95 179 - 32 - GW 95 170 - - GW 95 180 - NOTE: they are also compatible with RCBOs 1P+N and 2-pole (MDC 1P+N and 2P). ARD must be supplied with 230 V AC phase-neutral for working. 9

DEVICES TO BE COUPLED WITH MCBs AND ADD-ON RCDs 4 POLES GW 90 893 4 mod. + MCB MT 4 POLES 4 mod. Curve In (A) Icn = 6000 A Icn = 10000 A Icn = 25000 A C 1 GW 92 081 - - 2 GW 92 082 - - 3 GW 92 083 - - 4 GW 92 084 - - 6 GW 92 085 GW 92 685 GW 92 885 10 GW 92 086 GW 92 686 GW 92 886 13 GW 92 094 GW 92 694 - 16 GW 92 087 GW 92 687 GW 92 887 20 GW 92 088 GW 92 688 GW 92 888 25 GW 92 089 GW 92 689 GW 92 889 32 GW 92 090 GW 92 690 GW 92 890 40 GW 92 091 GW 92 691 GW 92 891 50 GW 92 092 GW 92 692 GW 92 892 63 GW 92 093 GW 92 693 GW 92 893 B 6 GW 92 285 GW 92 585 - 10 GW 92 286 GW 92 586 - 13 GW 92 294 GW 92 587 - 16 GW 92 287 GW 92 588 - 20 GW 92 288 GW 92 589 - 25 GW 92 289 GW 92 590 - 32 GW 92 290 GW 92 591 - 40 GW 92 291 GW 92 592 - 50 GW 92 292 GW 92 593 - 63 GW 92 293 GW 92 594 - D 1 - GW 92 781 - 2 - GW 92 782 - 3 - GW 92 783 - 4 - GW 92 784 - 6 GW 92 485 GW 92 785 - 10 GW 92 486 GW 92 786 - 13 GW 92 494 GW 92 794 - 16 GW 92 487 GW 92 787 - 20 GW 92 488 GW 92 788 - 25 GW 92 489 GW 92 789 - 32 GW 92 490 GW 92 790 - 40 GW 92 491 GW 92 791 -                               + Automatic reclosing device with/without circuit safety and/or short-circuit check. RESTART RM TOP NOTE: they are also compatible with MTC MCBs, MDC RCBOs, MT MCBs and BD add-on RCDs 1P+N, 2 and 3 poles. ARD must be supplied with 230 V AC phase-neutral for working. ADD-ON RESIDUAL CURRENT DEVICE BD 4 POLES 3.5 mod. In (A) IΔn (mA) AC type A type A[IR] type A[S] type ≤25 30 GW 94 422 GW 94 522 - - 300 GW 94 423 GW 94 523 - - 500 GW 94 424 GW 94 524 - - ≤63 30 GW 94 432 GW 94 532 GW 94 586 - 300 GW 94 433 GW 94 533 - GW 94 583 500 GW 94 434 GW 94 534 - - 1000 - - - GW 94 585 Selection tables 10 Automatic reclosing devices 90 R e S taRt   Range

RESTART WITH AUTOTEST (1)  Power supply 230V phase-neutral  (2)  In the absence of a system fault  (3)  Average daily temperature ≤ +35°C (4)  Choosing the NC + impulse option, the auxiliary contact switches for 100ms at the end of each successful Autotest cycle. TYPE RESTART WITH AUTOTEST 2P RESTART WITH AUTOTEST PRO 2P RESTART WITH AUTOTEST PRO 4P Electrical characteristicsReference Standards: EN 50557, EN 61008-1 Distribution system: TT - TN Rated operating voltage (Ue): (V) 230 AC  (1)  400 AC Minimum operating voltage (min Ue): (V) 85% Ue Maximum operating voltage (max Ue): (V) 110% Ue Rated insulation voltage (Ui): (V) 500 Dielectric strength test voltage between pole and earth: (V) 2500 AC for 1 minute Rated impulse withstand voltage (Uimp): (kV) 4 Rated frequency: (Hz) 50 Residual making and breaking capacity (IΔm): (A) 630 Rated conditional residual short-circuit current   with fuse (IΔc): (A) 10000 (gL 63A) for In=25-40A 10000 (gL 80A) for In=63A Number of poles: 2 4 Type of associated residual current circuit breaker: A[IR] Rated current (In): (A) 25 - 40 25 - 40 - 63 Rated residual operating current (IΔn): (mA) 30 30 - 300 Rated non-operating resistance between live parts and earth (Rdo): (kΩ) 20 8 8 (30mA) - 2.5 (300mA) Rated operating resistance between live parts and earth (Rd): (kΩ) 70 16 16 (30mA) - 5 (300mA) Power loss at In: (W) 2.2 (25A) - 5.4 (40A) - 6.2 (63A) 3.5 (25A) - 6 (40A) - 12 (63A) Off-load absorbed power: (VA) 4 (cosφ=0.2) Power absorbed during automatic reclosing: (VA) 41 (cosφ=0.5) Reclosing control: automatic Power supply: from above Mechanical  characteristics      Width in DIN modules: 5 7 Reclosing time: (s) 10 Autotest cycle time: (s) 7 Maximum operating frequency: (oper./h) 30 Max mechanical endurance (total no. operations): 4000 Maximum no. of consecutive automatic reclosure operations  (2) : 3 Counter reset time no. of consecutive automatic reclosure operations: (s) 60 Section of circuit breaker terminals: (mm 2 ) ≤ 35 flexible cable - ≤ 35 rigid cable Rated tightening torque: (Nm) 2 Degree of protection: IP20 (terminals) - IP40 (front) Operating temperature: (°C) -25 +40 -25 +60  (3) Storage temperature: (°C) -40 +70 Tropicalisation: 55°C - RH 95% Auxiliary contact characteristics        Type of contact: Photomos Operating voltage: (V) 5÷230 AC/DC Operating current: (mA) 0.6 (min) - 100 cosφ=1 (max) Operating frequency: (Hz) 50 Category of use: AC12 Operating mode: NO / NC / NC + impulse (4) Terminal section: (mm 2 ) ≤ 2.5 Rated tightening torque: (Nm) 0.4 A utOteSt  function Regular and automatic RCCB test: • • • Light signalling for autotest cycle in progress: • • • Light signalling for any device anomaly: • • • R e S taRt  function      Automatic reclosure for untimely tripping: • • • Earth failure test: • • • Continuous system check: • • Interruption of reclosure operation in the event of a fault: • • • Signalling of reclosure operation in progress: • • • Light signalling of failure: • • • Activation / exclusion of R e S taRt  function: • • • Auxiliary contact for remote operating status access: • • • Internal electrical protection: PTC PTC PTC Technical data 11

RESTART RD (1)  Power supply 230V phase-neutral  (2)  In the absence of a system fault  (3)  ≤ 25mm 2  for 4-pole versions in 3 modules             (4)  Average daily temperature ≤ +35°C TYPE RESTART RD 2P RESTART RD PRO 2P RESTART RD PRO 4P Electrical characteristicsReference Standards: EN 50557, EN 61008-1 EN 50557 Distribution system: TT - TN Rated operating voltage (Ue): (V) 230 AC  (1) Minimum operating voltage (min Ue): (V) 85% Ue Maximum operating voltage (max Ue): (V) 110% Ue Rated insulation voltage (Ui): (V) 500 Dielectric strength test voltage between pole and earth: (V) 2500 AC for 1 minute Rated impulse withstand voltage (Uimp): (kV) 4 Rated frequency: (Hz) 50 Residual making and breaking capacity (IΔm): (A) IΔm of the associated circuit breaker Rated conditional residual short-circuit current   with fuse (IΔc): (A) IΔc of the associated circuit breaker Number of poles: 2 4 Type of SD RCCB: A - A[IR] A - A[IR] - A[S] AC - A - A[IR] - A[S] Rated current (In): (A) 25 - 40 - 63 25 - 40 - 63 - 80 25 - 40 - 63 - 80 - 100 Rated residual operating current (IΔn): (mA) 30 30 - 100 - 300 - 500 30 - 100 - 300 - 500 Rated non-operating resistance between live parts and earth (Rdo): (kΩ) 20 8 (30mA) - 2.5 (100/300/500mA) 8 (30mA) - 2.5 (100/300/500mA) Rated operating resistance between live parts and earth (Rd): (kΩ) 70 16 (30mA) - 5 (100/300/500mA) 16 (30mA) - 5 (100/300/500mA) Power loss at In: (W) Power loss of the associated circuit breaker Off-load absorbed power: (VA) 0 17 (cosφ=0.2) 4 (cosφ=0.2) Power absorbed during automatic reclosing: (VA) 18 (cosφ=0.5) 45 (cosφ=0.5) Reclosing control: automatic Mechanical characteristics Width in DIN modules: 2 (reclosing device) + 2 (RCCB) 3 (reclosing device) Reclosing time: (s) 90 10 Maximum operating frequency: (oper./h) 15 30 Max mechanical endurance (total no. operations): 1000 4000 Maximum no. of consecutive automatic reclosure operations  (2) : 3 Counter reset time no. of consecutive automatic reclosure operations: (s) 180 60 Section of circuit breaker terminals: (mm 2 ) ≤ 35 flexible cable  (3)  - ≤ 35 rigid cable Rated tightening torque: (Nm) 2 Degree of protection: IP20 (terminals) - IP40 (front) Operating temperature: (°C) -5 +40 -25 +60  (4) Storage temperature:  (°C) -40 +70 Tropicalisation: 55°C - RH 95% Auxiliary contact characteristicsType of contact: - Photomos Operating voltage: (V) - 5÷230 AC/DC Operating current: (mA) - 0.6 (min) - 100 cosφ=1 (max)  Operating frequency: (Hz) - 50 Category of use: - AC12 Operating mode: - NO/NC/INTERMITTENT Terminal section: (mm 2 ) - ≤ 2.5 Rated tightening torque: (Nm) - 0.4 R e S taRt  function Automatic reclosure for untimely tripping: • • • Earth failure test: • • • Continuous system check: • • Interruption of reclosure operation in the event of a fault: • • • Signalling of reclosure operation in progress: • • • Light signalling of failure: • • • Activation / exclusion of R e S taRt  function: • • • Auxiliary contact for remote operating status access: • • Internal electrical protection: PTC PTC PTC Technical data 12 Automatic reclosing devices 90 R e S taRt   Range

RESTART RM TYPE RESTART RM 2P RESTART RM PRO 2P RESTART RM PRO 4P RM TOP CM Electrical characteristicsReference Standards: EN 50557, EN 61009-1 EN 50557 - - Distribution system: TT - TN TT - TN - IT  (1) TT-TN-IT Rated operating voltage (Ue): (V) 230 AC  (2) Minimum operating voltage (min Ue): (V) 85% Ue Maximum operating voltage (max Ue): (V) 110% Ue Rated insulation voltage (Ui): (V) 500 Dielectric strength test voltage between pole and earth: (V) 2500 AC for 1 minute Rated impulse withstand voltage (Uimp): (kV) 4 Rated frequency: (Hz) 50 Residual making and breaking capacity (IΔm): (A) IΔm of the associated circuit breaker Number of poles: 2 4 Type of MDC RCBO: A - A[IR] A - A[S] AC - A - A[IR] - A[S] AC - A - A[IR] - A[S] Type of MT+BD RCBO: - - - AC - A - A[IR] - A[S] Rated current (In): (A) from 6 to 32 from 1 to 63 Rated residual operating current (IΔn): (mA) 30 30 - 300 30 - 300 - 500 - 1000 Rated non-operating resistance between live parts and earth (Rdo):  (kΩ) 20 8 (30mA) - 2.5 (300mA) 8 (30mA) - 2.5 (300/500/1000mA) - Rated operating resistance between live parts and earth (Rd):  (kΩ) 70 16 (30mA) - 5 (300mA) 16 (30mA) - 5 (300/500/1000mA) - Rated non-operating resistance between live parts (Rcco): (Ω) 0.8 0.3 - Rated operating resistance between live parts (Rcc): (Ω) 1.3 1.8 - Power loss at In: (W) Power loss of the associated circuit breaker Off-load absorbed power: (VA) 0 17 (cosφ=0.2) 16 (cosφ=0.2) 15 (cosφ=0.1) 0 (cosφ=0.2) Power absorbed during automatic reclosing: (VA) 18 (cosφ=0.5) 34 (cosφ=0.7) 30 (cosφ=0.6) 30 (cosφ=0.6) Reclosing control: automatic automatic / remote  (3) remote  (3) Mechanical characteristics      Width in DIN modules: 2 (reclosing device)   + 2 (RCCB) 3 (reclosing device) 4 (reclosing device) 2 (reclosing  device) Reclosing time: (s) 90 10 3 (without system test) 10 (with system test) 3 Remote control opening time: (s) - - - 2 Maximum operating frequency: (oper./h) 15 30 Max mechanical endurance (total no. operations): 1000 4000 10000 Maximum no. of consecutive automatic reclosure operations  (4) : 3 - Counter reset time no. of consecutive automatic   reclosure operations: (s) 180 60 - Section of circuit breaker terminals: (mm 2 ) ≤ 35 flexible cable - ≤ 35 rigid cable Rated tightening torque: (Nm) 2 Degree of protection: IP20 (terminals) - IP40 (front) Operating temperature: (°C) -5 +40 -25 +60  (5) Storage temperature:  (°C) -40 +70 Tropicalisation: 55°C - RH 95% Auxiliary contact characteristicsType of contact: - Photomos Changeover Photomos Changeover Operating voltage: (V) - 5÷230 AC/DC 230 AC / 30 DC 5÷230 AC/DC 230 AC / 30 DC Operating current: (mA) - 0.6 (min) - 100 cosφ=1 (max) 1.5 AC / 0.8 DC 0.6 (min) - 100 cosφ=1 (max) 1.5 AC / 0.8 DC Operating frequency: (Hz) - 50 Category of use: - AC12 Operating mode: - NO/NC/INTERMITTENT CO NO/NC/INTERMITTENT CO Terminal section: (mm 2 ) - ≤ 2.5 Rated tightening torque: (Nm) - 0.4 R e S taRt   funCtiOn Automatic reclosure for untimely tripping: • • • • Earth failure test: • • • • Short-circuit check: • • • • Settable insulation threshold: • Continuous system check: • • • Adjustable reset standby time  (6) : • Settable reclosing mode: • Interruption of reclosure operation in the event of a fault: • • • • Signalling of reclosure operation in progress: • • • • Light signalling of failure: • • • • Activation / exclusion of R e S taRt  function: • • • • • Auxiliary contact for remote operating status access: • • • • Internal electrical protection: PTC PTC PTC PTC PTC (1)  For IT system reclosing without fault check (2)  Power supply 230V phase-neutral  (3)  Impulse duration ≥ 200ms (4)  In the absence of a system fault   (5)  Average daily temperature ≤ +35°C   (6)  Automatic reclosure delay time: 0÷1h Technical data 13

MtC MtHP MCB - MtC Miniature circuit   breakers Market  standard Compact   GEWISS 4P With the compact MCBs MTC you can protect 2 poles for each module.The  MT MCBs, based on unique and innovative design solutions and the use of high quality materials, stand out for their optimum performance, robustness and long-term reliability.The high-performance MTHP MCBs - up to 125A and with a breaking capacity of 16kA (EN 60947-2) - can be used both as a main switch and as circuit breaker protection in electrical boards with a high short-circuit current. MCBs for circuit protection Accessories to simplify use The complete integration among the circuit breakers and all electrical auxiliaries the 90 range allow to simply the accessory management. Maximum safety In addition to the characteristic of the double DIN clip, which allows a more steady mounting and facilitates maintenance operations, the terminals are supplied with protective and sliding insulation insert for the maximum safety of tightening and against any possible contacts with live parts. Quick identification The label holder is suitable for identification of the function of every circuit and it is available across the range. 2P -50%   overall  dimensions Mt 14 Modular circuit breakers for circuit protection 90 MCB range

MINIATURE CIRCUIT BREAKERS MTC MT Icn [A] (EN60898) Curve  In [A] 1P 1P+N 1P+N 2P 3P 4P 1P 1P+N 2P 3P 4P 1 mod. 1 mod. 1 mod. 1 mod. 2 mod. 2 mod. 1 mod. 2 mod. 2 mod. 3 mod. 4 mod. MTC 45 MT 45 4500 C 2 - GW 90 022 GW 90 602 - - - - - - - - 6 GW 90 005 GW 90 025 GW 90 605 GW 90 045 GW 90 065 GW 90 085 GW 92 105 GW 92 125 GW 92 145 GW 92 165 GW 92 185 10 GW 90 006 GW 90 026 GW 90 606 GW 90 046 GW 90 066 GW 90 086 GW 92 106 GW 92 126 GW 92 146 GW 92 166 GW 92 186 13 GW 90 011 GW 90 031 - GW 90 051 GW 90 071 GW 90 091 GW 92 107 GW 92 127 GW 92 147 GW 92 167 GW 92 187 16 GW 90 007 GW 90 027 GW 90 607 GW 90 047 GW 90 067 GW 90 087 GW 92 108 GW 92 128 GW 92 148 GW 92 168 GW 92 188 20 GW 90 008 GW 90 028 GW 90 608 GW 90 048 GW 90 068 GW 90 088 GW 92 109 GW 92 129 GW 92 149 GW 92 169 GW 92 189 25 GW 90 009 GW 90 029 GW 90 609 GW 90 049 GW 90 069 GW 90 089 GW 92 110 GW 92 130 GW 92 150 GW 92 170 GW 92 190 32 GW 90 010 GW 90 030 GW 90 610 GW 90 050 GW 90 070 GW 90 090 GW 92 111 GW 92 131 GW 92 151 GW 92 171 GW 92 191 40 - - - - - - GW 92 112 GW 92 132 GW 92 152 GW 92 172 GW 92 192 B 6 - - - - - - GW 92 305 GW 92 325 GW 92 345 GW 92 365 GW 92 385 10 - - - - - - GW 92 306 GW 92 326 GW 92 346 GW 92 366 GW 92 386 13 - - - - - - GW 92 307 GW 92 327 GW 92 347 GW 92 367 GW 92 387 16 - - - - - - GW 92 308 GW 92 328 GW 92 348 GW 92 368 GW 92 388 20 - - - - - - GW 92 309 GW 92 329 GW 92 349 GW 92 369 GW 92 389 25 - - - - - - GW 92 310 GW 92 330 GW 92 350 GW 92 370 GW 92 390 32 - - - - - - GW 92 311 GW 92 331 GW 92 351 GW 92 371 GW 92 391 40 - - - - - - GW 92 312 GW 92 332 GW 92 352 GW 92 372 GW 92 392 MTC 60 MT 60 6000 C 1 - - - - - - GW 92 001 GW 92 021 GW 92 041 GW 92 061 GW 92 081 2 - - - - - - GW 92 002 GW 92 022 GW 92 042 GW 92 062 GW 92 082 3 - - - - - - GW 92 003 GW 92 023 GW 92 043 GW 92 063 GW 92 083 4 - - - - - - GW 92 004 GW 92 024 GW 92 044 GW 92 064 GW 92 084 6 - GW 90 225 - GW 90 245 GW 90 265 GW 90 285 GW 92 005 GW 92 025 GW 92 045 GW 92 065 GW 92 085 10 - GW 90 226 - GW 90 246 GW 90 266 GW 90 286 GW 92 006 GW 92 026 GW 92 046 GW 92 066 GW 92 086 13 - GW 90 231 - GW 90 251 GW 90 271 GW 90 291 GW 92 014 GW 92 034 GW 92 054 GW 92 074 GW 92 094 16 - GW 90 227 - GW 90 247 GW 90 267 GW 90 287 GW 92 007 GW 92 027 GW 92 047 GW 92 067 GW 92 087 20 - GW 90 228 - GW 90 248 GW 90 268 GW 90 288 GW 92 008 GW 92 028 GW 92 048 GW 92 068 GW 92 088 25 - GW 90 229 - GW 90 249 GW 90 269 GW 90 289 GW 92 009 GW 92 029 GW 92 049 GW 92 069 GW 92 089 32 - GW 90 230 - GW 90 250 GW 90 270 GW 90 290 GW 92 010 GW 92 030 GW 92 050 GW 92 070 GW 92 090 40 - - - - - - GW 92 011 GW 92 031 GW 92 051 GW 92 071 GW 92 091 50 - - - - - - GW 92 012 GW 92 032 GW 92 052 GW 92 072 GW 92 092 63 - - - - - - GW 92 013 GW 92 033 GW 92 053 GW 92 073 GW 92 093 B 6 - GW 90 325 - GW 90 345 - - GW 92 205 - GW 92 245 GW 92 265 GW 92 285 10 - GW 90 326 - GW 90 346 - - GW 92 206 - GW 92 246 GW 92 266 GW 92 286 13 - GW 90 327 - GW 90 347 - - GW 92 214 - GW 92 254 GW 92 274 GW 92 294 16 - GW 90 328 - GW 90 348 - - GW 92 207 - GW 92 247 GW 92 267 GW 92 287 20 - GW 90 329 - GW 90 349 - - GW 92 208 - GW 92 248 GW 92 268 GW 92 288 25 - GW 90 330 - GW 90 350 - - GW 92 209 - GW 92 249 GW 92 269 GW 92 289 32 - GW 90 331 - GW 90 351 - - GW 92 210 - GW 92 250 GW 92 270 GW 92 290 40 - - - - - - GW 92 211 - GW 92 251 GW 92 271 GW 92 291 50 - - - - - - GW 92 212 - GW 92 252 GW 92 272 GW 92 292 63 - - - - - - GW 92 213 - GW 92 253 GW 92 273 GW 92 293 D 6 - - - - - - GW 92 405 - GW 92 445 GW 92 465 GW 92 485 10 - - - - - - GW 92 406 - GW 92 446 GW 92 466 GW 92 486 13 - - - - - - GW 92 414 - GW 92 454 GW 92 474 GW 92 494 16 - - - - - - GW 92 407 - GW 92 447 GW 92 467 GW 92 487 20 - - - - - - GW 92 408 - GW 92 448 GW 92 468 GW 92 488 25 - - - - - - GW 92 409 - GW 92 449 GW 92 469 GW 92 489 32 - - - - - - GW 92 410 - GW 92 450 GW 92 470 GW 92 490 40 - - - - - - GW 92 411 - GW 92 451 GW 92 471 GW 92 491 Miniature circuit breakers with neutral on the left Selection tables 15

MINIATURE CIRCUIT BREAKERS MTC MT MTHP Icn [A]  (EN60898) Curve  In [A] 1P+N 2P 1P 2P 3P 4P 1P 2P 3P 4P 1 mod. 1 mod. 1 mod. 2 mod. 3 mod. 4 mod. 1.5 mod. 3 mod. 4.5 mod. 6 mod. MTC 100 MT 100 10000 C 6 GW 90 425 GW 90 445 GW 92 605 GW 92 645 GW 92 665 GW 92 685 - - - - 10 GW 90 426 GW 90 446 GW 92 606 GW 92 646 GW 92 666 GW 92 686 - - - - 13 GW 90 431 GW 90 451 GW 92 614 GW 92 654 GW 92 674 GW 92 694 - - - - 16 GW 90 427 GW 90 447 GW 92 607 GW 92 647 GW 92 667 GW 92 687 - - - - 20 GW 90 428 GW 90 448 GW 92 608 GW 92 648 GW 92 668 GW 92 688 - - - - 25 GW 90 429 GW 90 449 GW 92 609 GW 92 649 GW 92 669 GW 92 689 - - - - 32 GW 90 430 GW 90 450 GW 92 610 GW 92 650 GW 92 670 GW 92 690 - - - - 40 - - GW 92 611 GW 92 651 GW 92 671 GW 92 691 - - - - 50 - - GW 92 612 GW 92 652 GW 92 672 GW 92 692 - - - - 63 - - GW 92 613 GW 92 653 GW 92 673 GW 92 693 - - - - B 6 - - GW 92 505 GW 92 545 GW 92 565 GW 92 585 - - - - 10 - - GW 92 506 GW 92 546 GW 92 566 GW 92 586 - - - - 13 - - GW 92 507 GW 92 547 GW 92 567 GW 92 587 - - - - 16 - - GW 92 508 GW 92 548 GW 92 568 GW 92 588 - - - - 20 - - GW 92 509 GW 92 549 GW 92 569 GW 92 589 - - - - 25 - - GW 92 510 GW 92 550 GW 92 570 GW 92 590 - - - - 32 - - GW 92 511 GW 92 551 GW 92 571 GW 92 591 - - - - 40 - - GW 92 512 GW 92 552 GW 92 572 GW 92 592 - - - - 50 - - GW 92 513 GW 92 553 GW 92 573 GW 92 593 - - - - 63 - - GW 92 514 GW 92 554 GW 92 574 GW 92 594 - - - - D 1 - - GW 92 701 GW 92 741 GW 92 761 GW 92 781 - - - - 2 - - GW 92 702 GW 92 742 GW 92 762 GW 92 782 - - - - 3 - - GW 92 703 GW 92 743 GW 92 763 GW 92 783 - - - - 4 - - GW 92 704 GW 92 744 GW 92 764 GW 92 784 - - - - 6 - - GW 92 705 GW 92 745 GW 92 765 GW 92 785 - - - - 10 - - GW 92 706 GW 92 746 GW 92 766 GW 92 786 - - - - 13 - - GW 92 714 GW 92 754 GW 92 774 GW 92 794 - - - - 16 - - GW 92 707 GW 92 747 GW 92 767 GW 92 787 - - - - 20 - - GW 92 708 GW 92 748 GW 92 768 GW 92 788 - - - - 25 - - GW 92 709 GW 92 749 GW 92 769 GW 92 789 - - - - 32 - - GW 92 710 GW 92 750 GW 92 770 GW 92 790 - - - - 40 - - GW 92 711 GW 92 751 GW 92 771 GW 92 791 - - - - MTHP 160 10000  (16kA  EN60947-2) C 80 - - - - - - GW 93 307 GW 93 327 GW 93 337 GW 93 347 100 - - - - - - GW 93 308 GW 93 328 GW 93 338 GW 93 348 125 - - - - - - GW 93 309 GW 93 329 GW 93 339 GW 93 349 D 63 - - - - - - GW 93 356 GW 93 376 GW 93 386 GW 93 396 80 - - - - - - GW 93 357 GW 93 377 GW 93 387 GW 93 397 100 - - - - - - GW 93 358 GW 93 378 GW 93 388 GW 93 398 MT 250 MTHP 250 12500 C 50 - - GW 92 812 GW 92 852 GW 92 872 GW 92 892 - - - - 63 - - GW 92 813 GW 92 853 GW 92 873 GW 92 893 - - - - 15000 C 32 - - GW 92 810 GW 92 850 GW 92 870 GW 92 890 - - - - 40 - - GW 92 811 GW 92 851 GW 92 871 GW 92 891 - - - - 20000 C 25 - - GW 92 809 GW 92 849 GW 92 869 GW 92 889 - - - - 25000 C 6 - - GW 92 805 GW 92 845 GW 92 865 GW 92 885 - - - - 10 - - GW 92 806 GW 92 846 GW 92 866 GW 92 886 - - - - 16 - - GW 92 807 GW 92 847 GW 92 867 GW 92 887 - - - - 20 - - GW 92 808 GW 92 848 GW 92 868 GW 92 888 GW 93 201 GW 93 221 GW 93 231 GW 93 241 25 - - - - - - GW 93 202 GW 93 222 GW 93 232 GW 93 242 32 - - - - - - GW 93 203 GW 93 223 GW 93 233 GW 93 243 40 - - - - - - GW 93 204 GW 93 224 GW 93 234 GW 93 244 50 - - - - - - GW 93 205 GW 93 225 GW 93 235 GW 93 245 63 - - - - - - GW 93 206 GW 93 226 GW 93 236 GW 93 246 16 Modular circuit breakers for circuit protection 90 MCB range

MDC BD and BDHP SD A circuit breaker   for every need Thanks to the wide possibility of choice, the 90 RCD range allows to meet all the needs of protection in electrical circuit with different types of earth fault currents, from sinusoidal alternating shape (AC type) and pulsanting (A type), due to the presence of electronic devices, up to smooth DC shape (B type) used, for example, for the protection of inverters, UPS and medical equipment. Quick test The Add-on RCD’s are provided with a test button which tests the correct mechanical coupling with circuit breaker before suppling. This is an important test that ensures the correct operation of trip mechanism. Moreover, the only one lever allows to identify the type of fault that has caused the device to trip. A yellow flag indicates earth fault. Without interruption In addition to AC, A and B types, the 90 RCD range offers also the Impulse Resistant IR ver-sion with high resistance to untimely tripping due to overvoltage impulses. This version is particularly suitable for installations where the continuity of service is extremely important. The IR version, available for MDC, BD and SD, stands out for its ability to provide safety and, at the same time, to not trip during atmospheric discharges, during driving with critical inrush current and in presence of harmonics that usu-ally open the standard RCD’s without real fault. B type A type AC type 100% 90% 50% 10% T1=8 T1(µ S) T2=20 I (peak) With the compact MDC RCBOs, you can protect one pole for each module.A range of modular devices for residual current protection at the forefront of performance. The SD RCCBs and add-on BD and BDHP RCDs for MT and MTHP circuit breakers offer quick assembly and unique innovation solutions.Wide range of versions:- instantaneous: type AC - A- impulse resistant: type A - B- selective: type A - B- with adjustable tripping threshold and time delay: type A RCBOs, RCCBs and ADD-ONs   for residual current protection RCBO - MDC Residual current circuit  breakers with overcurrent  protection Market  standard Compact   GEWISS 4P 2P -50%   overall  dimensions SD B type  17 Modular circuit breakers for residual current protection 90 RCD range

RESIDUAL CURRENT CIRCUIT BREAKERS IΔn = 30mA IΔn = 300mA Icn [A] (EN 61009-1) Curve  Type In [A] 1P+N 2P 3P 4P 1P+N 2P 3P 4P 2 mod. 2 mod. 3 mod. 4 mod. 2 mod. 2 mod. 3 mod. 4 mod. MDC 45 4500 C AC 6 GW 94 005 GW 94 025 GW 94 045 GW 94 065 GW 94 015 GW 94 035 GW 94 055 GW 94 075 10 GW 94 006 GW 94 026 GW 94 046 GW 94 066 GW 94 016 GW 94 036 GW 94 056 GW 94 076 13 GW 94 011 GW 94 031 GW 94 051 GW 94 071 - - - - 16 GW 94 007 GW 94 027 GW 94 047 GW 94 067 GW 94 017 GW 94 037 GW 94 057 GW 94 077 20 GW 94 008 GW 94 028 GW 94 048 GW 94 068 GW 94 018 GW 94 038 GW 94 058 GW 94 078 25 GW 94 009 GW 94 029 GW 94 049 GW 94 069 GW 94 019 GW 94 039 GW 94 059 GW 94 079 32 GW 94 010 GW 94 030 GW 94 050 GW 94 070 GW 94 020 GW 94 040 GW 94 060 GW 94 080 A 6 GW 94 205 GW 94 225 GW 94 245 GW 94 265 GW 94 215 GW 94 235 GW 94 255 GW 94 275 10 GW 94 206 GW 94 226 GW 94 246 GW 94 266 GW 94 216 GW 94 236 GW 94 256 GW 94 276 13 GW 94 211 GW 94 231 GW 94 251 GW 94 271 - - - - 16 GW 94 207 GW 94 227 GW 94 247 GW 94 267 GW 94 217 GW 94 237 GW 94 257 GW 94 277 20 GW 94 208 GW 94 228 GW 94 248 GW 94 268 GW 94 218 GW 94 238 GW 94 258 GW 94 278 25 GW 94 209 GW 94 229 GW 94 249 GW 94 269 GW 94 219 GW 94 239 GW 94 259 GW 94 279 32 GW 94 210 GW 94 230 GW 94 250 GW 94 270 GW 94 220 GW 94 240 GW 94 260 GW 94 280 MDC 60 6000 C AC 6 GW 94 105 GW 94 125 GW 94 145 GW 94 165 GW 94 115 GW 94 135 GW 94 155 GW 94 175 10 GW 94 106 GW 94 126 GW 94 146 GW 94 166 GW 94 116 GW 94 136 GW 94 156 GW 94 176 13 GW 94 111 GW 94 131 GW 94 151 GW 94 171 - - - - 16 GW 94 107 GW 94 127 GW 94 147 GW 94 167 GW 94 117 GW 94 137 GW 94 157 GW 94 177 20 GW 94 108 GW 94 128 GW 94 148 GW 94 168 GW 94 118 GW 94 138 GW 94 158 GW 94 178 25 GW 94 109 GW 94 129 GW 94 149 GW 94 169 GW 94 119 GW 94 139 GW 94 159 GW 94 179 32 GW 94 110 GW 94 130 GW 94 150 GW 94 170 GW 94 120 GW 94 140 GW 94 160 GW 94 180 A 6 GW 94 305 GW 94 325 GW 94 345 GW 94 365 GW 94 315 GW 94 335 GW 94 355 GW 94 375 10 GW 94 306 GW 94 326 GW 94 346 GW 94 366 GW 94 316 GW 94 336 GW 94 356 GW 94 376 13 GW 94 311 GW 94 331 GW 94 351 GW 94 371 - - - - 16 GW 94 307 GW 94 327 GW 94 347 GW 94 367 GW 94 317 GW 94 337 GW 94 357 GW 94 377 20 GW 94 308 GW 94 328 GW 94 348 GW 94 368 GW 94 318 GW 94 338 GW 94 358 GW 94 378 25 GW 94 309 GW 94 329 GW 94 349 GW 94 369 GW 94 319 GW 94 339 GW 94 359 GW 94 379 32 GW 94 310 GW 94 330 GW 94 350 GW 94 370 GW 94 320 GW 94 340 GW 94 360 GW 94 380 A[IR] 6 - GW 95 805 - GW 95 815 - - - - 10 - GW 95 806 - GW 95 816 - - - - 13 - GW 95 811 - GW 95 821 - - - - 16 - GW 95 807 - GW 95 817 - - - - 20 - GW 95 808 - GW 95 818 - - - - 25 - GW 95 809 - GW 95 819 - - - - 32 - GW 95 810 - GW 95 820 - - - - A[S] 16 - - - - - GW 95 847 - GW 95 857 20 - - - - - GW 95 848 - GW 95 858 25 - - - - - GW 95 849 - GW 95 859 32 - - - - - GW 95 850 - GW 95 860 B A 6 GW 95 105 GW 95 125 GW 95 145 GW 95 165 GW 95 115 GW 95 135 GW 95 155 GW 95 175 10 GW 95 106 GW 95 126 GW 95 146 GW 95 166 GW 95 116 GW 95 136 GW 95 156 GW 95 176 13 GW 95 111 GW 95 131 GW 95 151 GW 95 171 - - - - 16 GW 95 107 GW 95 127 GW 95 147 GW 95 167 GW 95 117 GW 95 137 GW 95 157 GW 95 177 20 GW 95 108 GW 95 128 GW 95 148 GW 95 168 GW 95 118 GW 95 138 GW 95 158 GW 95 178 25 GW 95 109 GW 95 129 GW 95 149 GW 95 169 GW 95 119 GW 95 139 GW 95 159 GW 95 179 32 GW 95 110 GW 95 130 GW 95 150 GW 95 170 GW 95 120 GW 95 140 GW 95 160 GW 95 180 Selection tables 18 90 RCD range Modular circuit breakers for residual current protection

ADD-ON RESIDUAL CURRENT DEVICES (EN 61009-1 APP. G) BD BDHP Type IΔn [mA] 2P 3P 4P 2P 3P 4P 2 mod. 3.5 mod. 3.5 mod. 4 mod. 6 mod. 6 mod. In≤25A In≤63A In≤25A In≤63A In≤25A In≤63A In≤125A In≤125A In≤125A AC 10 GW 94 401 - - - - - - - - 30 GW 94 402 GW 94 412 GW 94 442 GW 94 448 GW 94 422 GW 94 432 GW 95 406 GW 95 416 GW 95 426 300 GW 94 403 GW 94 413 GW 94 443 GW 94 449 GW 94 423 GW 94 433 GW 95 408 GW 95 418 GW 95 428 500 GW 94 404 GW 94 414 GW 94 444 GW 94 450 GW 94 424 GW 94 434 - - - A 30 GW 94 502 GW 94 512 GW 94 542 GW 94 547 GW 94 522 GW 94 532 GW 95 436 GW 95 446 GW 95 456 300 GW 94 503 GW 94 513 GW 94 543 GW 94 548 GW 94 523 GW 94 533 GW 95 438 GW 95 448 GW 95 458 500 GW 94 504 GW 94 514 GW 94 544 GW 94 549 GW 94 524 GW 94 534 - - - A[IR] 30 GW 94 566 GW 94 595 GW 94 586 - - - A[S] 300 GW 94 563 GW 94 598 GW 94 583 GW 95 468 GW 95 478 GW 95 488 1000 GW 94 565 GW 94 600 GW 94 585 GW 95 470 GW 95 480 GW 95 490 A reg. 300-3000 - - - - - GW 95 512 RESIDUAL CURRENT CIRCUIT BREAKERS IΔn = 30mA IΔn = 100mA IΔn = 300mA Icn [A] (EN 61009-1) Curve  Type In [A] 1P+N 2P 3P 2P 1P+N 2P 2 mod. 2 mod. 3 mod. 2 mod. 2 mod. 2 mod. MDC 100 10000 C AC 6 GW 95 005 GW 95 025 GW 95 025 MA - - GW 95 015 GW 95 035 GW 95 035 MA 10 GW 95 006 GW 95 026 GW 95 026 MA - - GW 95 016 GW 95 036 GW 95 036 MA 13 GW 95 011 GW 95 031 GW 95 031 MA - - - - - 16 GW 95 007 GW 95 027 GW 95 027 MA - - GW 95 017 GW 95 037 GW 95 037 MA 20 GW 95 008 GW 95 028 GW 95 028 MA - - GW 95 018 GW 95 038 GW 95 038 MA 25 GW 95 009 GW 95 029 GW 95 029 MA - - GW 95 019 GW 95 039 GW 95 039 MA 32 GW 95 010 GW 95 030 GW 95 030 MA - - GW 95 020 GW 95 040 GW 95 040 MA A 6 GW 95 205 GW 95 225 GW 95 225 MA GW 95 245 GW 95 785 GW 95 215 GW 95 235 GW 95 235 MA 10 GW 95 206 GW 95 226 GW 95 226 MA GW 95 246 GW 95 786 GW 95 216 GW 95 236 GW 95 236 MA 13 GW 95 211 GW 95 231 GW 95 231 MA - GW 95 791 - - - 16 GW 95 207 GW 95 227 GW 95 227 MA GW 95 247 GW 95 787 GW 95 217 GW 95 237 GW 95 237 MA 20 GW 95 208 GW 95 228 GW 95 228 MA GW 95 248 GW 95 788 GW 95 218 GW 95 238 GW 95 238 MA 25 GW 95 209 GW 95 229 GW 95 229 MA GW 95 249 GW 95 789 GW 95 219 GW 95 239 GW 95 239 MA 32 GW 95 210 GW 95 230 GW 95 230 MA GW 95 250 GW 95 790 GW 95 220 GW 95 240 GW 95 240 MA A[IR] 6 - GW 95 825 - - - - 10 - GW 95 826 - - - - 13 - GW 95 831 - - - - 16 - GW 95 827 - - - - 20 - GW 95 828 - - - - 25 - GW 95 829 - - - - 32 - GW 95 830 - - - - B A 6 - GW 95 325 - GW 95 795 - GW 95 335 10 - GW 95 326 - GW 95 796 - GW 95 336 13 - GW 95 331 - GW 95 801 - - 16 - GW 95 327 - GW 95 797 - GW 95 337 20 - GW 95 328 - GW 95 798 - GW 95 338 25 - GW 95 329 - GW 95 799 - GW 95 339 32 - GW 95 330 - GW 95 800 - GW 95 340 A[IR] 6 - GW 95 835 - - - - 10 - GW 95 836 - - - - 13 - GW 95 841 - - - - 16 - GW 95 837 - - - - 20 - GW 95 838 - - - - 25 - GW 95 839 - - - - 32 - GW 95 840 - - - - RCD SAFETY SOCKETS FLUSH-MOUNTING  RCDs HOUSING   FOR SURFACE-MOUNTING In [A] Ue [V] Type IΔn [mA] IP21 IP44 IP41 IP44 16 230 A 10 GW 95 921 GW 95 923 GW 95 925 GW 95 928 30 GW 95 922 GW 95 924 GW 95 926 Rated operating voltage equal to 110V AC Rated operating voltage equal to 230V AC 19

4 modules RESIDUAL CURRENT CIRCUIT BREAKERS (EN 61008-1) SD 2P 4P In [A] Type IΔn [mA] 2 mod. 3 mod. 4 mod. 4 mod. 25 AC 10 GW 94 616 - - - 30 GW 94 617 GW 94 662 GW 94 697 GW 94 637 100 GW 94 618 - GW 94 698 - 300 GW 94 619 GW 94 664 GW 94 699 GW 94 639 A 10 GW 94 816 GW 94 866 - - 30 GW 94 817 GW 94 867 GW 94 877 GW 94 552 100 GW 94 818 - GW 94 878 - 300 GW 94 819 GW 94 869 GW 94 879 GW 94 554 A[IR] 30 GW 95 651 - GW 95 676 - 300 - - GW 95 678 - B[IR] 30 GW 95 701 - GW 95 716 - 300 - - GW 95 718 - 40 AC 30 GW 94 627 GW 94 667 GW 94 707 GW 94 647 100 GW 94 628 GW 94 668 GW 94 708 - 300 GW 94 629 GW 94 669 GW 94 709 GW 94 649 500 GW 94 630 GW 94 670 GW 94 710 - A 30 GW 94 827 GW 94 897 GW 94 927 GW 94 557 100 GW 94 828 GW 94 898 GW 94 928 - 300 GW 94 829 GW 94 899 GW 94 929 GW 94 559 500 GW 94 830 GW 94 900 GW 94 930 - A[IR] 30 GW 95 656 - GW 95 681 - 300 - - GW 95 683 - A[S] 300 GW 94 924 - GW 94 966 - B[IR] 30 GW 95 706 - GW 95 721 - 300 - - GW 95 723 - 63 AC 30 GW 94 790 - GW 94 757 GW 94 717 100 GW 94 791 - GW 94 758 - 300 GW 94 792 - GW 94 759 GW 94 719 500 GW 94 789 - GW 94 760 - A 30 GW 94 837 - GW 94 937 GW 94 907 100 GW 94 838 - GW 94 938 - 300 GW 94 839 - GW 94 939 GW 94 909 500 GW 94 840 - GW 94 940 - A[IR] 30 GW 95 661 - GW 95 686 - 300 - - GW 95 688 - A[S] 300 GW 94 934 - GW 94 976 - B[IR] 30 - - GW 95 726 - 300 - - GW 95 728 - 500 - - GW 95 729 - B[S] 300 - - GW 95 737 - 80 AC 30 GW 94 793 - GW 94 761 GW 94 727 100 GW 94 794 - GW 94 771 - 300 GW 94 795 - GW 94 766 GW 94 728 A 30 GW 94 847 - GW 94 947 - 100 GW 94 848 - GW 94 948 - 300 GW 94 849 - GW 94 949 - A[S] 300 GW 94 944 - GW 94 986 - B[IR] 30 - - GW 95 731 - 300 - - GW 95 733 - B[S] 300 - - GW 95 743 - 100 AC 30 - - GW 94 777 GW 94 737 100 - - GW 94 778 - 300 - - GW 94 779 GW 94 739 500 - - GW 94 780 - A 30 - - GW 94 957 - 100 - - GW 94 958 - 300 - - GW 94 959 - 500 - - GW 94 960 - A[IR] 30 - - GW 95 696 - 300 - - GW 95 698 - A[S] 300 - - GW 94 996 - 125 AC 30 - - GW 95 601 - 300 - - GW 95 603 - 500 - - GW 95 604 - A 30 - - GW 95 606 - 300 - - GW 95 608 - 500 - - GW 95 609 - RCDs with neutral on the left 20 Modular circuit breakers for residual current protection 90 RCD range

PIN BUSBARS FORK BUSBARS ISOLATED  TERMINAL FOR   PIN BUSBARS BUSBAR END  CAPS  PROTECTION CAPS 12 mod. 1 metre 12 mod. 1 metre 5 pieces For MT-MDC 1P GW 96 984 GW 96 988 GW 96 992 GW 96 996 GW 96 961 GW 96 963 GW 96 967 2P GW 96 985 GW 96 989 GW 96 993 GW 96 997 GW 96 964 3P GW 96 986 GW 96 990 GW 96 994 GW 96 998 GW 96 965 4P GW 96 987 GW 96 991 GW 96 995 GW 96 999 GW 96 962 GW 96 966 12 mod. 5 pieces For MDC Up to 6 MDC 1P+N / 2P - GW 96 491 - - GW 96 967 13 mod. 1 metre 5 pieces For MTC 1P (grey) GW 96 500 - - GW 96 503 - GW 96 967 1P (blue) GW 96 501 - - - 1P (white)  - GW 96 988 - - 13 mod. 6 mod. 12 mod. 5 pieces For SD 2P Up to 11 MTC 1P+N / 2P GW 96 504 F - - - - GW 96 967 For SD 4P 3 mod. Up to 9 MT 1P / 3 MT 3P - GW 96 071 GW 96 969 - - GW 96 492 For SD 4P 4 mod. Up to 8 MT 1P  - - GW 96 493 - - AUXILIAR Y C ONT AC T FOR  OPEN/CL OSED POSITION GW 96 001 FA UL T INDIC AT OR SWIT CH GW 96 006 ADJUST ABLE A UXILIAR Y  CONT AC T (POSITION/TRIPPED ) GW 96 009 SHUNT TRIP  RELEASES GW 96 011 (12-48V AC/DC)GW 96 012 (110-125V DC) (110-415V AC)  UNDER V OL TA GE    RELEASES GW 96 016  (230V AC)GW 96 017 (24V AC/DC)GW 96 018  (48V AC/DC)  M TC MT M THP MDC GW 96 007 AUXILIAR Y C ONT AC T FOR  OPEN/CL OSED POSITION SD  B T YP E The  auxiliary contacts and shunt trip releases, common to all MCBs and RCBOs, allow simplicity, interchangeability, multiple uses and rationalisation of the items. The range is completed by modular auxiliaries specifically for the RCCB range. The busbars reduce the wiring and labour times, without the need to use cables and crimps. They are available in pin and fork versions with 12 modules, up to one metre long. Electrical auxiliaries and busbars SD 4P GW 96 003 (SD 25-100A)  AUXILIAR Y C ONT AC T FOR  OPEN/CL OSED POSITION GW 96 005 (SD 125A)  AUXILIAR Y C ONT AC T  FOR  OPEN/CL OSED POSITION GW 96 004 (SD 25-100A) FA UL T INDIC AT OR  SWIT CH GW 96 015 (SD 25-100A) SHUNT TRIP  RELEASE     Suitable for compensating any difference in height between main circuit breakers (SD) and outgoing circuit breakers (MT).  21 Modular accessories 90 AM range

LST surge protective  devices LST - SURGE PROTECTIVE DEVICES TYPE 1+2 TYPE 2 1P+N 3P+N 1P 1P+N 3P+N Imax (kA) 230V 400V 230V 400V 230V 400V 20 - - - - GW D6 407 GW D6 409 2 mod. 4 mod. 40 - - GW D6 411 GW D6 413 GW D6 417 GW D6 419 1 mod. 2 mod. 4 mod. GW D6 412 1 mod. GW D6 418 GW D6 420 1 mod. 2 mod. 4 mod. 65 (Iimp=12.5kA) GW D6 401 GW D6 402 - - - - 2 mod. 4 mod. 100 (Iimp=25kA) GW D6 404 GW D6 405 - - - - 4 mod. 8 mod. AC DISCONNECTABLE FUSE-HOLDERS In (A) Fuse dim. (mm) 1P 1P+N 2P 3P 3P+N 20 8.3x31.5 GW 96 206 GW 96 216 GW 96 301 GW 96 306 GW 96 311 1 mod. 2 mod. 2 mod. 3 mod. 4 mod. 32 10.3x38 GW 96 205 GW 96 215 GW 96 302 GW 96 307 GW 96 312 1 mod. 2 mod. 2 mod. 3 mod. 4 mod. - GW 96 220 - - - 1 mod. 50 14x51 GW 96 207 GW 96 217 GW 96 303 GW 96 308 GW 96 313 1.5 mod. 3 mod. 3 mod. 4.5 mod. 6 mod. 100 22x58 - GW 96 218 - - GW 96 314 4 mod. 8 mod. MOTOR PROTECTION SWITCHES In (A) 3 mod. 0.1 - 0.16 GW 96 751 0.16 - 0.25 GW 96 752 0.25 - 0.4 GW 96 753 0.4 - 0.63 GW 96 754 0.63 - 1 GW 96 755 1 - 1.6 GW 96 756 1.6 - 2.5 GW 96 757 2.5 - 4 GW 96 758 4 - 6.3 GW 96 759 6.3 - 10 GW 96 760 10 - 16 GW 96 761 16 - 25 GW 96 762 25 - 40 GW 96 763 RCD RELAY GW 96 331 3 mod. + SEPARATE TOROID Diameter (mm) In max (A) Code 35 125 GW 96 332 80 400 GW 96 333 110 630 GW 96 334 110 630 GW 96 336 210 1600 GW 96 335 210 1600 GW 96 337    With auxiliary contact Solid-core current transformer Split-core current transformer This range of accessories guarantees excellent protection of loads and power distribution systems. The range includes: - LST surge protective devices- disconnectable fuse-holders - residual current relay with separate toroid- motor protection switches Protection Compact fuse-holder 22 Modular accessories 90 AM range

CTR contactors The command accessories allow the connection and disconnection of loads and the isolation of the electrical system. The range is made up of:- switch disconnectors- latching relays- control relays- CTR contactors- installation relays Command AC switch  disconnectors AC SWITCH DISCONNECTORS 1P 2P 3P 4P In (A) 1 mod. 2 mod. 3 mod. 4 mod. 32 GW 96 104 GW 96 114 GW 96 124 GW 96 134 40 GW 96 105 GW 96 115 GW 96 125 GW 96 135 63 GW 96 146 GW 96 156 GW 96 166 GW 96 176 80 GW 96 147 GW 96 157 GW 96 167 GW 96 177 100 GW 96 148 GW 96 158 GW 96 168 GW 96 178 125 GW 96 149 GW 96 159 GW 96 169 GW 96 179 CONTROL RELAYS Current  monitoring Phase   monitoring Undervoltage  monitoring  1-phase AC/ DC Undervoltage  monitoring  3-phase AC GW 96 906 GW 96 907 GW 96 908 GW 96 909 CTR CONTACTORS In (A) 20 25 40 63 Coil voltage (V) 24 AC 230 AC 24 AC-DC 230 AC-DC 24 AC-DC 230 AC-DC 24 AC-DC 230 AC-DC TY PE OF C ONT AC TS 1 NO - GW D6 701 - - - - - - 1 mod. 2 NO GW D6 702 GW D6 741 GW D6 703 GW D6 742   GW D6 711 GW D6 712 GW D6 751 - GW D6 721 - GW D6 731 1 mod. 1 mod. 2 mod. 2 mod. 3 mod. 3 mod. 3 NO - GW D6 708 - GW D6 713 GW D6 752 - GW D6 722 - GW D6 732 2 mod. 2 mod. 3 mod. 3 mod. 3 NO + 1 NC - - - GW D6 718 - - - GW D6 735 2 mod. 3 mod. 4 NO - GW D6 709 GW D6 714 GW D6 753 GW D6 715 GW D6 754  GW D6 723 GW D6 724 GW D6 733 GW D6 734 2 mod. 2 mod. 2 mod. 3 mod. 3 mod. 3 mod. 3 mod. 2 NC - GW D6 705 GW D6 743 - - - - - - 1 mod. 4 NC - - GW D6 716 GW D6 717 - - - - 2 mod. 2 mod. 1 NO + 1 NC GW D6 706 GW D6 707 GW D6 744 - - - - - - 1 mod. 1 mod. 2 NO + 2 NC - - - - - GW D6 725 - - 3 mod. LATCHING RELAYS In (A) 16 Coil voltage (V) 8 AC 12 AC 24 AC 230 AC TY PE OF C ONT AC TS 1 NO 1 mod. GW 96 624 GW 96 621 GW 96 622 GW 96 623 GW 96 652  GW 96 653 2 NO 1 mod. - GW 96 636 GW 96 637 GW 96 638 2 mod. - - GW 96 662 - - - GW 96 664  GW 96 663 3 NO 2 mod. - - GW 96 667 GW 96 668 GW 96 669 4 NO 2 mod. - GW 96 641 GW 96 642 GW 96 643 1 NO +  1 NC 1 mod. - GW 96 631 GW 96 632 GW 96 633 1 CO 1 mod. GW 96 625 GW 96 626 GW 96 627 GW 96 628 GW 96 630 GW 96 657 GW 96 658 GW 96 659 2 CO 1 mod. - - GW 96 673 GW 96 674 GW 96 676 DC voltage  With central command function DC voltage with central command function INSTALLATION RELAYS In (A) 16 Coil voltage (V) 8 AC 12 AC 24 AC 230 AC TY PE OF C ONT AC TS 1 NO 1 mod. GW 96 604 GW 96 601  GW 96 602 GW 96 603 2 NO 1 mod. - - - GW 96 615 4 NO 2 mod. - GW 96 616 GW 96 617 GW 96 618 1 NO + 1 NC 1 mod. - GW 96 606 GW 96 607 GW 96 608 1 CO 1 mod. GW 96 921 GW 96 922 GW 96 923 GW 96 924 GW 96 925  GW 96 926 2 CO 1 mod. GW 96 614 GW 96 611 GW 96 612 GW 96 913 GW 96 932 DC voltage Manual control version 23

Digital time switches STAIRCASE LIGHTING TIMERS With switch-off warning Without switch-off warning GW 96 813 GW 96 810 ASTRONOMICAL   SWITCH TWILIGHT   SWITCHES Without outdoor probe With outdoor probe GW 96 821 GW 96 891 1 CO 3 mod. GW 96 892 1 NO 1 mod. TIMERS Multifunction timer Asymmetrical timer GW 96 814 GW 96 815 TIME SWITCHES Analogue GW 96 830 1 NO (daily) No reserve charge 1 mod. GW 96 831 1 CO (daily) 150h reserve charge 3 mod. GW 96 832 1 CO (weekly) 150h reserve charge 3 mod. GW 96 836 1 NO (daily) 50h reserve charge 1 mod. Digital (daily and weekly) GW 96 844 1 CO 2 mod. GW 96 845 2 CO 2 mod. GW 96 846 1 CO 1 mod. Thanks to their versatility, the programming accessories allow electric loads to be controlled and managed in the widest possible variety of system configurations, offering even simpler and more intuitive flexible use for the most common installation situations. Programming Twilight switches 24 90 AM range Modular accessories

VOLTMETERS Analogue Digital GW 96 861 0-300V 3 mod. GW 96 867 2 mod. GW 96 862 0-500V Multimeter DIGITAL ENERGY METERS Three-phase  Single-phase GW D6 806 Direct (max 80A) 4 mod. GW D6 801 1 mod. GW D6 808 Using CT / 5A AMMETERS Analogue Digital GW 96 871 Direct (max 10A) 3 mod. GW 96 879 2 mod. GW 96 872 Direct (max 20A) GW 96 873 Direct (max 30A)  GW 96 878  Using CT / 5A DIGITAL MEASUREMENT DEVICES Network analyser Multimeter GW 96 899 4 mod. GW 96 897 2 mod. The range of analogue and digital measurement instruments monitor the main parameters of the electrical system, making it possible to receive immediate information about the electrical values such as voltage, current, energy, etc. Measurement Network analyser 25

INDICATOR LAMPS 1 mod. Un (V) LED colour 12-24-48 AC/DC 230 AC Red GW 96 586 GW 96 581 Green GW 96 587 GW 96 582 Yellow GW 96 588 GW 96 583 Blue GW 96 589 GW 96 584 White GW 96 590 GW 96 585 Green and red  - GW 96 591 Triple red - GW 96 592 PUSH-BUTTONS WITH LED 1 mod. Un (V) Type of contact LED colour 12-24-48 AC/DC 230 AC 1 NO Green GW 96 570 GW 96 566 1 NC Red GW 96 571 GW 96 567 1 NO + 1 NC Green - GW 96 568 1 NO + 1 NC Red - GW 96 569 BELLS AND BUZZERS Un (V) 12 230 Bells 1 mod. GW 96 401 - - GW 96 402 2 mod. - GW 96 403 Buzzers 1 mod. GW 96 406 - - GW 96 407 2 mod. - GW 96 408 Bell + Buzzer +  Transformer 2 mod. - GW 96 411 BELL TRANSFORMERS A (VA) Secondary voltage (V) No. of modules 12 24 5 GW 96 421 GW 96 422 2 mod. 10 GW 96 423 GW 96 424 15 GW 96 425 GW 96 426 30 GW 96 431 GW 96 432 3 mod. 40 GW 96 433 GW 96 434 SAFETY TRANSFORMERS A (VA) Secondary voltage (V) No. of modules 24 15 GW 96 321 3 mod. 25 GW 96 322 40 GW 96 323 4 mod. 63 GW 96 324 6 mod. The signalling accessories allow the luminous (with LED technology) and acoustic signalling of alarms, voltage presence, circuit control with an indicator lamp, low voltage circuit power supply. Signalling Bells and buzzers  Indicator lamps and push-buttons 26 90 AM range Modular accessories

DC switch disconnectors DC LST surge protective device DC fuse-holders The 90 PV range includes 6 string board versions that meet the various installation requirements in the photovoltaic sector - whether residential, commercial or industrial. Each string board version has a different number of strings or string voltage level.In addition to string boards, the range also includes modular products specifically for the DC side of the photovoltaic system, such as:• switch disconnectors• surge protective devices• fuse-holders and fuses Products for photovoltaic systems Already tested certified The string boards have been tested in the GEWISS laboratories, passing all the tests envisaged by standards EN 61439-1 and EN 61439-2 for product certification. Ready to be connected The string boards are already complete with cable glands and terminal blocks enabling quick and easy safe connection to the system. The cable glands are supplied as spare parts, so the connection cable can be made according to individual needs (from the top, bottom or sides). They are supplied with insulated and earth terminals. The ideal range   for every application The 90 PV range contains 6 versions to meet the most varying photovoltaic plant engineering requirements, from residential applications to commercial/industrial sectors. The different versions are distinguished by the number of strings that can be managed and by the voltage level of the photovoltaic plants. String boards 27 90 PV range Products for photovoltaic systems

4 STRINGS - 600V DC - 50A GW D9903 Pre-wired board for connecting 4 strings of photovoltaic panels to the inverter. Includes: • watertight enclosure • 1 rotary switch disconnector 4-pole • 1 surge protective device with extractable cartridges • 4 disconnectable fuse-holders TECHNICAL DATA Reference Standards: EN 61439-1 and EN 61439-2 No. of modules of 40CDK enclosure: 2x12 Degree of protection: IP65 Insulation class: Class II Rated voltage of the switch disconnector (Ue): 600V DC Rated current of the switch disconnector (In): 50A (2 poles in parallel) Rated voltage of the SPD (Un): 600V DC Connection cable section: 6mm ² 3 STRINGS - 600V DC - 25A GW D9902 Pre-wired board for connecting 3 strings of photovoltaic panels to the inverter. Includes: • watertight enclosure • 1 rotary switch disconnector 2-pole • 1 surge protective device with extractable cartridges • 3 disconnectable fuse-holders TECHNICAL DATA Reference Standards: EN 61439-1 and EN 61439-2 No. of modules of 40CDK enclosure: 2x12 Degree of protection: IP65 Insulation class: Class II Rated voltage of the switch disconnector (Ue): 600V DC Rated current of the switch disconnector (In): 25A Rated voltage of the SPD (Un): 600V DC Connection cable section: 6mm ² 90 PV RANGE - PRE-WIRED STRING BOARDS 2 STRINGS - 600V DC - 25A GW D9901 Pre-wired board for connecting 1 or 2 strings of photovoltaic panels to the inverter. Includes: • watertight enclosure • 1 rotary switch disconnector 2-pole • 1 surge protective device with extractable cartridges TECHNICAL DATA Reference Standards: EN 61439-1 and EN 61439-2 No. of modules of 40CDK enclosure: 1x12 Degree of protection: IP65 Insulation class: Class II Rated voltage of the switch disconnector (Ue): 600V DC Rated current of the switch disconnector (In): 25A Rated voltage of the SPD (Un): 600V DC Connection cable section: 6mm ² STRING BOARD EQUIPMENT: cable glands (supplied loose) and equipotential terminal blocks. STRING BOARD EQUIPMENT: cable glands (supplied loose) and equipotential terminal blocks. NB: DC fuses not supplied. STRING BOARD EQUIPMENT: cable glands (supplied loose) and equipotential terminal blocks. NB: DC fuses not supplied. 28 90 PV range Products for photovoltaic systems

2 STRINGS - 800V DC - 20A GW D9906 Pre-wired board for connecting 1 or 2 strings of photovoltaic panels to the inverter. Includes: • watertight enclosure • 1 rotary switch disconnector 2-pole • 1 surge protective device with extractable cartridges TECHNICAL DATA Reference Standards: EN 61439-1 and EN 61439-2 No. of modules of 40CDK enclosure: 1x12 Degree of protection: IP65 Insulation class: Class II Rated voltage of the switch disconnector (Ue): 800V DC Rated current of the switch disconnector (In): 20A Rated voltage of the SPD (Un): 1000V DC Connection cable section: 6mm ² 3 STRINGS - 1000V DC - 32A GW D9907 Pre-wired board for connecting 3 strings of photovoltaic panels to the inverter. Includes: • watertight enclosure • 1 rotary switch disconnector 4-pole • 1 surge protective device with extractable cartridges • 3 disconnectable fuse-holders TECHNICAL DATA Reference Standards: EN 61439-1 and EN 61439-2 No. of modules of 40CDK enclosure: 2x12 Degree of protection: IP65 Insulation class: Class II Rated voltage of the switch disconnector (Ue): 1000V DC Rated current of the switch disconnector (In): 32A (4 poles in series) Rated voltage of the SPD (Un): 1000V DC Connection cable section: 6mm ² 4 STRINGS - 1000V DC - 32A GW D9908 Pre-wired board for connecting 4 strings of photovoltaic panels to the inverter. Includes: • watertight enclosure • 1 rotary switch disconnector 4-pole • 1 surge protective device with extractable cartridges • 4 disconnectable fuse-holders TECHNICAL DATA Reference Standards: EN 61439-1 and EN 61439-2 No. of modules of 40CDK enclosure: 2x12 Degree of protection: IP65 Insulation class: Class II Rated voltage of the switch disconnector (Ue): 1000V DC Rated current of the switch disconnector (In): 32A (4 poles in series) Rated voltage of the SPD (Un): 1000V DC Connection cable section: 6mm ² STRING BOARD EQUIPMENT: cable glands (supplied loose) and equipotential terminal blocks. STRING BOARD EQUIPMENT: cable glands (supplied loose) and equipotential terminal blocks. NB: DC fuses not supplied. STRING BOARD EQUIPMENT: cable glands (supplied loose) and equipotential terminal blocks. NB: DC fuses not supplied. 29

SURGE PROTECTIVE DEVICES LST Surge protective devices with extractable cartridge,  suitable for photovoltaic applications up to 1000V DC TECHNICAL DATA Reference Standards: EN 61643-11 Type: Type 2 (8/20 µs) Rated discharge current (In): 20kA Maximum discharge current (Imax): 40kA Back-up protection: if Icc 100A DC, fuse type gPV ≤ 20A if Icc 100A DC, protection not necessary Code Rated voltage of the SPD   (Un) Maximum continuous  operating voltage (Uc) Voltage protection  level at In (Up) Modules GW D6 426 600V DC 700V DC ≤ 2.6kV 3 GW D6 428 1000V DC 1170V DC ≤ 4kV 3 90 PV RANGE - MODULAR DEVICES IN DIRECT CURRENT SWITCH DISCONNECTORS Compact DC switch disconnector suitable for photovoltaic  installations up to 32A 1000V DC TECHNICAL DATA Reference Standards: EN 60947-3 Utilisation category: DC21B / DC22B Rated insulation voltage (Ui): 1000V Rated impulse withstand voltage (Uimp): 8kV Operating temperature: -40 to +65°C Max. cable section: 16mm² (solid or stranded) 10mm 2  (flexible, also with terminals) Code Modules Poles Utilisation  category Rated operating voltage (Ue) 600V DC 800V DC 1000V DC Rated operating current (In) GW 96 186 3.5 2 DC21B 25A 20A 11A DC22B 6A 2.5A 1.5A GW 96 187 3.5 4 DC21B 32A 32A 32A DC22B 27.5A 12.5A 10A SPARE CARTRIDGES - GW D6 446 suitable for SPD GW D6 426. - GW D6 448 suitable for SPD GW D6 428. DISCONNECTABLE FUSE-HOLDERS Fuse-holder bases for protection and   isolation of the photovoltaic strings TECHNICAL DATA Reference Standards: EN 60947-3 Utilisation category: DC20B Rated operating voltage (Ue): 1000V DC Rated current (In): 20A Max power loss: 3W Code Poles Modules GW 96 226 1 1 GW 96 227 2 2 FUSES The fuses are type gPV, as required   for photovoltaic applications TECHNICAL DATA Reference Standards: IEC 60269-6 Dimensions: 10.3 x 38mm Type: gPV Rated operating voltage (Ue): 1000V DC Breaking capacity: 30kA DC Code Rated current (In) GW 72 131 6 GW 72 132 8 GW 72 133 10 GW 72 134 12 GW 72 135 16 GW 72 136 20 30 90 PV range Products for photovoltaic systems

MTX 160 MTX 250 / MTXM 250 MTX 320 / MTXE 320 / MTXM 320 MTX 630 / MTXE 630 / MTXM 630 MTX 1000 / MTXE 1000 / MTXM  1000 MTSE 1600 / MTSM 1600 The  MTX range is the best solution for industrial installations and advanced commercial applications where there is a need for high rated current and breaking capacity, perfectly integrated with the CVX 47 boards. The range offers a wide selection of accessories to meet all installation requirements. Moulded-case circuit breakers  for power distribution Complete and specific accessories The MTX range is full of common accessories that streamline the installation and allow to reach additional functions such as remote opening, operating status by remote, engine control etc. Positive operation The operating lever always indicates the precise position of the moving contacts of the circuit-breaker, thereby guaranteeing safe and reliable signals, in compliance with the prescriptions of the IEC 60073 and IEC 60417-2 Standard. The circuit-breaker operating mechanism has free release regardless of the pressure on the lever and the speed of the operation. Ideal range for every need The moulded case circuit breakers MTX range is made up of circuit breakers with thermo-magnetic release, circuit breakers with magnetic release only, circuit breakers with electronic release, switch disconnectors, add-on residual current circuit breaker. MtX 160 C  / MtXM 160 C 31 MTX range Moulded-case circuit breakers for power distribution

MTX/E 160 Release In [A] N (36kA) S (50kA) H (70kA) 3P 4P 3P 4P 3P 4P THERM AL M AGNE TIC TM 1 M agnetic    thr eshold 10 I th 10 GW D7 931 GW D7 936 - - - - 16 GW D7 932 GW D7 937 - - - - 20 GW D7 933 GW D7 938 - - - - 25 GW D7 934 GW D7 939 - - - - GENER AT OR   PR OTEC TION  - T MG M agnetic thr eshold 3 I th 25 GW D7 081 GW D7 091 - - - - 40 GW D7 082 GW D7 092 - - - - 63 GW D7 083 GW D7 093 - - - - 80 GW D7 084 GW D7 094 - - - - 100 GW D7 085 GW D7 095 - - - - 125 GW D7 086 GW D7 096 - - - - 160 GW D7 087 GW D7 097 - - - - ELEC TR ONIC SEP/1 I 10 GW D7 146 GW D7 156 GW D7 166 GW D7 176 GW D7 186 GW D7 196 25 GW D7 147 GW D7 157 GW D7 167 GW D7 177 GW D7 187 GW D7 197 63 GW D7 148 GW D7 158 GW D7 168 GW D7 178 GW D7 188 GW D7 198 100 GW D7 149 GW D7 159 GW D7 169 GW D7 179 GW D7 189 GW D7 199 160 GW D7 150 GW D7 160 GW D7 170 GW D7 180 GW D7 190 GW D7 200 LS/I 10 GW D7 141 GW D7 151 GW D7 161 GW D7 171 GW D7 181 GW D7 191 25 GW D7 142 GW D7 152 GW D7 162 GW D7 172 GW D7 182 GW D7 192 63 GW D7 143 GW D7 153 GW D7 163 GW D7 173 GW D7 183 GW D7 193 100 GW D7 144 GW D7 154 GW D7 164 GW D7 174 GW D7 184 GW D7 194 160 GW D7 145 GW D7 155 GW D7 165 GW D7 175 GW D7 185 GW D7 195 M AGNE TIC ONL Y MO TOR PR OTEC TION - M M agnetic thr eshold 13 I th 1 GW D7 101 - GW D7 121 - - - 1.6 GW D7 102 - GW D7 122 - - - 2 GW D7 103 - GW D7 123 - - - 2.5 GW D7 104 - GW D7 124 - - - 3.2 GW D7 105 - GW D7 125 - - - 4 GW D7 106 - GW D7 126 - - - 5 GW D7 107 - GW D7 127 - - - 6.5 GW D7 108 - GW D7 128 - - - 8.5 GW D7 109 - GW D7 129 - - - 11 GW D7 110 - GW D7 130 - - - 12.5 GW D7 111 - GW D7 131 - - - M agnetic   thr eshold 6÷12 I th 20 GW D7 112 - GW D7 132 - - - 32 GW D7 113 - GW D7 133 - - - 52 GW D7 114 - GW D7 134 - - - 80 GW D7 115 - GW D7 135 - - - 100 GW D7 116 - GW D7 136 - - - MTX 160C Release In [A] B (16kA) C (25kA) N (36kA) 3P 4P 3P 4P 3P 4P THERM AL M AGNE TIC TM 1 M agnetic thr eshold 10 I th 16 GW D7 001 GW D7 021 - - - - 20 GW D7 002 GW D7 022 - - - - 25 GW D7 003 GW D7 023 GW D7 041 GW D7 051 - - 32 GW D7 004 GW D7 024 GW D7 042 GW D7 052 GW D7 061 GW D7 071 40 GW D7 005 GW D7 025 GW D7 043 GW D7 053 GW D7 062 GW D7 072 50 GW D7 006 GW D7 026 GW D7 044 GW D7 054 GW D7 063 GW D7 073 63 GW D7 007 GW D7 027 GW D7 045 GW D7 055 GW D7 064 GW D7 074 80 GW D7 008 GW D7 028 GW D7 046 GW D7 056 GW D7 065 GW D7 075 100 GW D7 009 GW D7 029 GW D7 047 GW D7 057 GW D7 066 GW D7 076 125 GW D7 010 GW D7 030 GW D7 048 GW D7 058 GW D7 067 GW D7 077 160 GW D7 011 GW D7 031 GW D7 049 GW D7 059 GW D7 068 GW D7 078 NOTE: can be fixed on the DIN EN 50022 profile using the GW D8 261 fixing bracket. NOTE: can be fixed on the DIN EN 50022 profile using the GW D8 261 fixing bracket. Selection tables 32 MTX range Moulded-case circuit breakers for power distribution

MTX 250 Release In [A] N (36kA) S (50kA) 3P 4P 3P 4P THERM AL M AGNE TIC TM 1 M agnetic thr eshold 10 I th 63 GW D7 201 GW D7 211 GW D7 221 GW D7 231 80 GW D7 202 GW D7 212 GW D7 222 GW D7 232 100 GW D7 203 GW D7 213 GW D7 223 GW D7 233 125 GW D7 204 GW D7 214 GW D7 224 GW D7 234 160 GW D7 205 GW D7 215 GW D7 225 GW D7 235 200 GW D7 206 GW D7 216 GW D7 226 GW D7 236 250 GW D7 207 GW D7 217 GW D7 227 GW D7 237 THERM AL M AGNE TIC GENER AT OR   PR OTEC TION  - T MG M agnetic thr eshold 3 I th 63 GW D7 241 GW D7 251 GW D7 261 GW D7 271 80 GW D7 242 GW D7 252 GW D7 262 GW D7 272 100 GW D7 243 GW D7 253 GW D7 263 GW D7 273 125 GW D7 244 GW D7 254 GW D7 264 GW D7 274 160 GW D7 245 GW D7 255 GW D7 265 GW D7 275 200 GW D7 246 GW D7 256 GW D7 266 GW D7 276 250 GW D7 247 GW D7 257 GW D7 267 GW D7 277 M AGNE TIC  ONL Y MO TOR  PR OTEC TION - M M agnetic  thr eshold 6÷12 I th 100 GW D7 281 - GW D7 291 - 125 GW D7 282 - GW D7 292 - 160 GW D7 283 - GW D7 293 - 200 GW D7 284 - GW D7 294 - MTX/E 320 Release In [A] N (36kA) S (50kA) H (70kA) L (120kA) 3P 4P 3P 4P 3P 4P 3P 4P THERM AL  M AGNE TIC TM 2 M agnetic thr eshold  5÷10 I th 100 GW D7 301 GW D7 311 GW D7 321 GW D7 331 - - - - 125 GW D7 302 GW D7 312 GW D7 322 GW D7 332 - - - - 160 GW D7 303 GW D7 313 GW D7 323 GW D7 333 - - - - 200 GW D7 304 GW D7 314 GW D7 324 GW D7 334 - - - - 250 GW D7 305 GW D7 315 GW D7 325 GW D7 335 - - - - ELEC TR ONIC SEP/1 I 100 GW D7 344 GW D7 364 GW D7 384 GW D7 404 GW D7 424 GW D7 444 GW D7 464 GW D7 484 160 GW D7 345 GW D7 365 GW D7 385 GW D7 405 GW D7 425 GW D7 445 GW D7 465 GW D7 485 250 GW D7 346 GW D7 366 GW D7 386 GW D7 406 GW D7 426 GW D7 446 GW D7 466 GW D7 486 320 GW D7 354 GW D7 374 GW D7 394 GW D7 414 GW D7 434 GW D7 454 GW D7 474 GW D7 494 LS/I 100 GW D7 341 GW D7 361 GW D7 381 GW D7 401 GW D7 421 GW D7 441 GW D7 461 GW D7 481 160 GW D7 342 GW D7 362 GW D7 382 GW D7 402 GW D7 422 GW D7 442 GW D7 462 GW D7 482 250 GW D7 343 GW D7 363 GW D7 383 GW D7 403 GW D7 423 GW D7 443 GW D7 463 GW D7 483 320 GW D7 353 GW D7 373 GW D7 393 GW D7 413 GW D7 433 GW D7 453 GW D7 473 GW D7 493 SEP/2 LSI 100 GW D7 347 GW D7 367 GW D7 387 GW D7 407 GW D7 427 GW D7 447 GW D7 467 GW D7 487 160 GW D7 348 GW D7 368 GW D7 388 GW D7 408 GW D7 428 GW D7 448 GW D7 468 GW D7 488 250 GW D7 349 GW D7 369 GW D7 389 GW D7 409 GW D7 429 GW D7 449 GW D7 469 GW D7 489 320 GW D7 355 GW D7 375 GW D7 395 GW D7 415 GW D7 435 GW D7 455 GW D7 475 GW D7 495 LSIG 100 GW D7 350 GW D7 370 GW D7 390 GW D7 410 GW D7 430 GW D7 450 GW D7 470 GW D7 490 160 GW D7 351 GW D7 371 GW D7 391 GW D7 411 GW D7 431 GW D7 451 GW D7 471 GW D7 491 250 GW D7 352 GW D7 372 GW D7 392 GW D7 412 GW D7 432 GW D7 452 GW D7 472 GW D7 492 320 GW D7 356 GW D7 376 GW D7 396 GW D7 416 GW D7 436 GW D7 456 GW D7 476 GW D7 496 NOTE: can be fixed on the DIN EN 50022 profile using the GW D8 262 fixing bracket. 33

MTSE 1600 Release In [A] S (50kA) H (65kA) L (100kA) 3P 4P 3P 4P 3P 4P ELEC TR ONIC SEP/A I 1250 GW 97 601 GW 97 607 GW 97 625 GW 97 631 GW 97 649 GW 97 655 1600 GW 97 602 GW 97 608 GW 97 626 GW 97 632 GW 97 650 GW 97 656 LI 1250 GW 97 604 GW 97 610 GW 97 628 GW 97 634 GW 97 652 GW 97 658 1600 GW 97 605 GW 97 611 GW 97 629 GW 97 635 GW 97 653 GW 97 659 SEP/B LSI 1250 GW 97 613 GW 97 619 GW 97 637 GW 97 643 GW 97 661 GW 97 667 1600 GW 97 614 GW 97 620 GW 97 638 GW 97 644 GW 97 662 GW 97 668 LSIG 1250 GW 97 616 GW 97 622 GW 97 640 GW 97 646 GW 97 664 GW 97 670 1600 GW 97 617 GW 97 623 GW 97 641 GW 97 647 GW 97 665 GW 97 671 MTX/E 1000 Release In [A] N (36kA) S (50kA) H (70kA) L (100kA) 3P 4P 3P 4P 3P 4P 3P 4P THERM AL  M AGNE TIC TM 2 M agnetic  thr eshold 5÷10 I th 630 GW D7 701 GW D7 706 GW D7 710 GW D7 716 GW D7 721 GW D7 726 - - 800 GW D7 702 GW D7 707 GW D7 711 GW D7 717 GW D7 722 GW D7 727 - - ELEC TR ONIC SEP/1 I 630 GW D7 732 GW D7 752 GW D7 772 GW D7 792 GW D7 812 GW D7 832 GW D7 852 GW D7 872 800 GW D7 736 GW D7 756 GW D7 776 GW D7 796 GW D7 816 GW D7 836 GW D7 856 GW D7 876 1000 GW D7 740 GW D7 760 GW D7 780 GW D7 800 GW D7 820 GW D7 840 GW D7 860 GW D7 880 LS/I 630 GW D7 731 GW D7 751 GW D7 771 GW D7 791 GW D7 811 GW D7 831 GW D7 851 GW D7 871 800 GW D7 735 GW D7 755 GW D7 775 GW D7 795 GW D7 815 GW D7 835 GW D7 855 GW D7 875 1000 GW D7 739 GW D7 759 GW D7 779 GW D7 799 GW D7 819 GW D7 839 GW D7 859 GW D7 879 SEP/2 LSI 630 GW D7 733 GW D7 753 GW D7 773 GW D7 793 GW D7 813 GW D7 833 GW D7 853 GW D7 873 800 GW D7 737 GW D7 757 GW D7 777 GW D7 797 GW D7 817 GW D7 837 GW D7 857 GW D7 877 1000 GW D7 741 GW D7 761 GW D7 781 GW D7 801 GW D7 821 GW D7 841 GW D7 861 GW D7 881 LSIG 630 GW D7 734 GW D7 754 GW D7 774 GW D7 794 GW D7 814 GW D7 834 GW D7 854 GW D7 874 800 GW D7 738 GW D7 758 GW D7 778 GW D7 798 GW D7 818 GW D7 838 GW D7 858 GW D7 878 1000 GW D7 742 GW D7 762 GW D7 782 GW D7 802 GW D7 822 GW D7 842 GW D7 862 GW D7 882 MTX/E 630 Release In [A] N (36kA) S (50kA) H (70kA) L (120kA) 3P 4P 3P 4P 3P 4P 3P 4P THERM AL   M AGNE TIC TM 2 M agnetic  thr eshold 5÷10 I th 320 GW D7 501 GW D7 506 GW D7 511 GW D7 516 GW D7 521 GW D7 526 - - 400 GW D7 502 GW D7 507 GW D7 512 GW D7 517 GW D7 522 GW D7 527 - - 500 GW D7 503 GW D7 508 GW D7 513 GW D7 518 GW D7 523 GW D7 528 - - ELEC TR ONIC SEP/1 I 400 GW D7 534 GW D7 554 GW D7 574 GW D7 594 GW D7 614 GW D7 634 GW D7 654 GW D7 674 630 GW D7 540 GW D7 560 GW D7 580 GW D7 600 GW D7 620 GW D7 640 GW D7 660 GW D7 680 LS/I 400 GW D7 532 GW D7 552 GW D7 572 GW D7 592 GW D7 612 GW D7 632 GW D7 652 GW D7 672 630 GW D7 539 GW D7 559 GW D7 579 GW D7 599 GW D7 619 GW D7 639 GW D7 659 GW D7 679 SEP/2 LSI 400 GW D7 536 GW D7 556 GW D7 576 GW D7 596 GW D7 616 GW D7 636 GW D7 656 GW D7 676 630 GW D7 541 GW D7 561 GW D7 581 GW D7 601 GW D7 621 GW D7 641 GW D7 661 GW D7 681 LSIG 400 GW D7 538 GW D7 558 GW D7 578 GW D7 598 GW D7 618 GW D7 638 GW D7 658 GW D7 678 630 GW D7 542 GW D7 562 GW D7 582 GW D7 602 GW D7 622 GW D7 642 GW D7 662 GW D7 682 34 MTX range Moulded-case circuit breakers for power distribution

MTXM SWITCH DISCONNECTORS MTXM 160c MTXM 250 MTXM 320 MTXM 400 - 630 MTXM 800 - 1000 MTSM 1600 In [A] 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 3P 4P 160 GW D7 901 GW D7 902 - - - - - - - - - - 250 - - GW D7 903 GW D7 904 - - - - - - - - 320 - - - - GW D7 905 GW D7 906 - - - - - - 400 - - - - - - GW D7 907 GW D7 908 - - - - 630 - - - - - - GW D7 909 GW D7 910 - - - - 800 - - - - - - - - GW D7 911 GW D7 912 - - 1000 - - - - - - - - GW D7 913 GW D7 914 - - 1250 - - - - - - - - - - GW 97 715 GW 97 718 1600 - - - - - - - - - - GW 97 716 GW 97 719 NOTE: MTXM 160c and MTXM 250 can be fixed on the DIN EN 50022 profile using the specific fixing brackets. OPENING RELEASES SHUNT-TRIP UNDER VOLTAGE Suitable for MTX/E/M 160c - 160 - 250 MTX/E/M 320 - 1000 MTSE/M 1600 MTX/E/M 160c - 160 - 250 MTX/E/M 320 - 1000 MTSE/M 1600 Supply v oltage 12V DC GW D8 101 - - - - - 24-30V AC/DC GW D8 102 GW D8 107 GW 98 260 GW D8 117 GW D8 122 GW 98 281 (AC)GW 98 288 (DC) 48-60V AC/DC GW D8 103 GW D8 108 GW 98 261 GW D8 118 GW D8 123 GW 98 282 (AC)GW 98 289 (DC) 127V AC - 125V DC GW D8 104 GW D8 109 GW 98 263 GW D8 119 GW D8 124 GW 98 284 (AC)GW 98 291 (DC) 240V AC - 250V DC GW D8 105 GW D8 110 GW 98 264 GW D8 120 GW D8 125 GW 98 285 (AC)GW 98 292 (DC) 380 - 400V AC GW D8 106 GW D8 111 GW 98 265 GW D8 121 GW D8 126 GW 98 286 (AC) ADD-ON RESIDUAL CURRENT DEVICES “L” SHAPED PLACED BELOW Suitable for MTX/M 160c MTX/E 160 MTX/M 250 MTX/E/M 320 MTXM 400 - MTX/E/M 630 Versions For 4P circuit breakers only For 4P circuit breakers only Instantaneous GW D8 242 GW D8 244 GW D8 246 - - Adjustable GW D8 241 (reduced height) GW D8 245 GW D8 247 GW D8 248 (up to 500A) GW D8 249 (up to 500A) GW D8 243 NOTE: the L-shaped devices can be fixed on the DIN EN 50022 profile using the specific bracket. For the GWD8241 add-on residual current device, use the GWD8266 fixing bracket. For the GWD8242, GWD8243, GWD8244 and GWD8245 residual current devices, use the GWD8263 fixing bracket. For the  GWD8246 and GWD8247 residual current devices, use the GWD8264 fixing bracket. 35

MSS 250 MSS 630 3-way switch  I 0 II MSS 160 ATS MSS 160 Thanks to their state-of-the-art technological solutions, the MSS switch disconnectors guarantee high performance both in AC and in DC, ensuring the maximum hold even in the event of short-circuiting or with a high number of operations in heavy working conditions. Rotary switch disconnectors Perfect integration Thanks to the dedicated installation kit MSS switch disconnectors are perfectly integrated with the 47 CVX distribution boards. The high versatility of the MSS disconnectors allow a total synergy with the 46 range of automation and distribution boards. Reliable change-over The simplicity of the set-up of the MSS 160 ATS product, the different functions (with excludable automatic return to a priority line) and self-powering (L-N directly from the main line) make it a high performing product and highly competitive in automatic change-over application for 2 low voltage networks. Fully accessorized For specific applications, the switch-discon-nectors can be fitted with IP65 watertight rota-ry handles (shaft extension included), auxiliary contacts, terminal covers, parallel connections. MSS 125 36 97 MSS range Rotary switch disconnectors

TERMINAL COVERS (1 CODE = 1 PIECE) MSS 160 MSS 250 MSS 630 MSS 160 ATS AUTOMATIC THREE-WAY SWITCH 3P - 4P 3P 4P 3P 4P 4P GW 98 508 GW 98 509 GW 98 510 GW 98 511 GW 98 512 GW 97 773 AUXILIARY CONTACTS MSS 125 - MSS 160 MSS 250 - MSS 630 MSS 125 - THREE-WAY SWITCH (I 0 II) MSS 160 ATS - AUTOMATIC THREE-WAY SWITCH GW 98 514 GW 98 515 GW 98 516 GW 97 774 Note: all the rotary handles include transmission rods. DOOR COUPLING ROTARY HANDLES - IP65 MSS 125 - MSS 160 MSS 250 - MSS 630 MSS 125 - THREE-WAY SWITCH (I 0 II) Black handle Red handle Black handle Red handle Black handle GW 98 521 GW 98 524 GW 98 522 GW 98 525 GW 98 523 MSS SWITCH DISCONNECTORS MSS 125 MSS 160 MSS 250 MSS 630 MSS 125 THREE-WAY SWITCH (I 0 II) MSS ATS 160 AUTOMATIC  THREE-WAY SWITCH In [A] 3P 4P 3P 4P 3P 4P 3P 4P 4P 4P 63 GW 97 721 GW 97 724 - - - - - - - - 100 GW 97 722 GW 97 725 - - - - - - - - 125 GW 97 723 GW 97 726 - - - - - - GW 97 761 - 160 - - GW 97 727 GW 97 728 - - - - - GW 97 767 250 - - - - GW 97 729 GW 97 730 - - - - 400 - - - - - - GW 97 731 GW 97 733 - - 630 - - - - - - GW 97 732 GW 97 734 - - Selection tables 37

The CVX160 I and CVX160 E ranges offer the widest choice for protection in indoor contexts, not to mention a modern, practical design.The  CVX 160 I range has flush-mounting boards with a degree of protection up to IP40 and up to In=160A. The choice of board is simple and quick (only one GW code) because the DIN rails, front panels and all the fixing accessories are already included.The  CVX 160 E range has wall-mounting boards with a degree of protection up to IP65 and up to In=160A. The range enables the creation of configurations to suit specific needs, from a minimum capacity of 72 modules to a maximum of 192, choosing the appropriate installation kit (150mm or 200mm pitch). Metal boards   up to 160A Installation without   screws and tools The fixing supports have been designed to be mounted without screws thanks to pre-holed on the function sides. Moreover the innovative support allows the fixing of the din rails on the brackets and their adjustments in depth without using any tools. Quick fastening   of the insulating panel The front panels in plastic material allow for quick fixing by means of two inserts ¼ turn and the earthing connection is not necessary. For all range it is supplied a kit for the installation of the hinges on the front panels. Easy and   fast installation The extractable frame allows wiring desk and, subsequently, the installation of the wired frame inside the casing when the system is completed. 38 Distribution boards up to 160A 47 CVX 160 I/E range 

CVX 160 I STRUCTURES PRE-ASSEMBLED BOARDS COMPLETE WITH DIN RAILS AND FRONT PANELS, WITH FIXING ACCESSORIES INCLUDED STRUCTURES FUNCTIONAL DIM. (LxH) 600x600mm 600x800mm 600x1000mm GENERAL CHARACTERISTICS NO. EN 50022 MODULES (17.5mm) In: up to 160A Capacity: 24 modules per row  Installation: indoors Colour: Grey RAL 7035 96 120 144 No. of rows x No. of modules 4 rows x 24 modules 5 rows x 24 modules 6 rows x 24 modules Height of panels  with windows: (mm) 150 200 (first row)  150 (the other rows) 200 (first two rows)  150 (the other rows) IP30 without door GW 47 072 GW 47 073 GW 47 074 IP40 glass door GW 47 082 GW 47 083 GW 47 084 solid door GW 47 087 GW 47 088 GW 47 089 EN 50022 modules (17.5mm) Selection tables 39 Flush-mounting distribution boards up to 160A 47 CVX 160 I range

Selection tables 40 47 CVX 160 E range Surface-mounting distribution boards up to 160A CVX 160 E STRUCTURES  GENERAL CHARACTERISTICS STRUCTURES In: up to 160A Capacity: 24 modules per row Installation: indoor Colour: Grey RAL 7035 FUNCTIONAL DIM. (LxH) 600x600mm 600x800mm 600x1000mm 600x1200mm IP30 without door GW 47 001 E GW 47 002 E GW 47 003 E GW 47 004 E IP40 glass door GW 47 011 E GW 47 012 E GW 47 013 E GW 47 014 E solid door GW 47 021 E GW 47 022 E GW 47 023 E GW 47 024 E IP55 glass door GW 47 031 E GW 47 032 E GW 47 033 E GW 47 034 E solid door GW 47 041 E GW 47 042 E GW 47 043 E GW 47 044 E IP65 solid door - GW 47 062 E GW 47 063 E GW 47 064 E NOTE: the codes do not include the DIN rail and front panels.

41 47 CVX 630 K - M range Modular distribution boards up to 630A The CVX 630 K and CVX 630 M ranges offer the widest choice for protection in indoor contexts, not to mention a modern, practical design.The CVX 630 K range offers both wall-mounting and floor-mounting modular boards with a degree of protection up to IP43 and up to In=630A.The CVX 630 M range offers both wall-mounting and floor-mounting monobloc boards with a degree of protection up to IP55 and up to In=630A.  Metal boards   up to 630A Simple and quick wiring The CVX 630K modular distribution boards are designed to make wiring and assembly operations easier and quicker. In fact, the wiring can be carried out with the structures "fully open" and then the board assembly can be completed. Synergy CVX 630 K and CVX 630 M use the same installation kit and accessories as for modular and moulded-case devices. Easier assembly   and maintenance The metallic components of the board ensure a contact earth connection, hence avoiding the need for additional connections. The front panels are fitted with hinges and unlosable screws for easier maintenance on the installed board.

CVX 630 K (WALL-MOUNTING) STRUCTURES STRUCTURES FUNCTIONAL DIM. (LxH) 600x1000mm 600x1200mm 850x1000mm 850x1200mm Modular capacity Pitch 150mm 144 mod.  (24x6) 192 mod.  (24x8) 144 mod.  (24x6) 216 mod.  (36x6) 192 mod.  (24x8) 288 mod.  (36x8) Pitch 200mm 120 mod.  (24x5) 144 mod.  (24x6) 120 mod.  (24x5) 180 mod.  (36x5) 144 mod.  (24x6) 216 mod.  (36x6) Structures GW 45 004 GW 45 005 GW 45 014 GW 45 015 Sides GW 45 024 GW 45 025 GW 45 024 GW 45 025 Curved glass doors GW 45 104 GW 45 105 GW 45 114 GW 45 115 Solid doors GW 45 124 GW 45 125 GW 45 134 GW 45 135 Internal cable   compartment - - GW 45 034 GW 45 035 Side-by-side   installation kit GW 45 504 GW 45 505 GW 45 504 GW 45 505 Selection tables 42 47 CVX 630 K range Modular boards up to 630A - IP43

CVX 630 K (FLOOR-MOUNTING) STRUCTURES STRUCTURES FUNCTIONAL DIM. (LxH) 600x1600mm 600x1800mm 600x2000mm 850x1600mm 850x1800mm 850x2000mm Modular capacity Pitch 150mm 240 mod.  (24x10) 288 mod.  (24x12) 312 mod.  (24x13) 240 mod.  (24x10) 360 mod.  (36x10) 288 mod.  (24x12) 432 mod.  (36x12) 312 mod.  (24x13) 468 mod.  (36x13) Pitch 200mm 192 mod.  (24x8) 216 mod.  (24x9) 240 mod.  (24x10) 192 mod.  (24x8) 288 mod.  (36x8) 216 mod.  (24x9) 324 mod.  (36x9) 240 mod.  (24x10) 360 mod.  (36x10) Structures GW 45 007 GW 45 008 GW 45 009 GW 45 017 GW 45 018 GW 45 019 Sides GW 45 027 GW 45 028 GW 45 029 GW 45 027 GW 45 028 GW 45 029 Curved glass doors GW 45 107 GW 45 108 GW 45 109 GW 45 117 GW 45 118 GW 45 119 Solid doors GW 45 127 GW 45 128 GW 45 129 GW 45 137 GW 45 138 GW 45 139 Internal cable   compartment - - - GW 45 037 GW 45 038 GW 45 039 Side-by-side   installation kit GW 45 507 GW 45 508 GW 45 509 GW 45 507 GW 45 508 GW 45 509 EXTERNAL CABLE COMPARTMENT FUNCTIONAL DIM. (LxH) 400x1600mm 400x1800mm 400x2000mm External cable  compartment GW 45 047 GW 45 048 GW 45 049 Internal solid doors GW 45 352 GW 45 353 GW 45 354 External solid doors GW 45 147 GW 45 148 GW 45 149 43

CVX 630 M (WALL-MOUNTING) STRUCTURES STRUCTURES FUNCTIONAL DIM. (LxH) 600x1000mm 600x1200mm 850x1000mm 850x1200mm Modular capacity Pitch 150mm 144 mod.  (24x6) 192 mod.  (24x8) 144 mod.  (24x6) 216 mod.  (36x6) 192 mod.  (24x8) 288 mod.  (36x8) Pitch 200mm 120 mod.  (24x5) 144 mod.  (24x6) 120 mod.  (24x5) 180 mod.  (36x5) 144 mod.  (24x6) 216 mod.  (36x6) Structures GW 45 054 GW 45 055 GW 45 064 GW 45 065 Solid side panels GW 45 074 GW 45 075 GW 45 074 GW 45 075 Aerated side panels GW 45 394 GW 45 395 GW 45 394 GW 45 395 Curved glass doors GW 45 154 GW 45 155 GW 45 164 GW 45 165 Solid doors GW 45 174 GW 45 175 GW 45 184 GW 45 185 Internal cable   compartment - - GW 45 084 GW 45 085 Side-by-side   installation kit Plates GW 45 533 GW 45 533 GW 45 533 GW 45 533 IP55  Gasket GW 47 473 GW 47 473 GW 47 473 GW 47 473 Selection tables 44 47 CVX 630 M range Monobloc distribution boards up to 630A - IP55

45 CVX 630 M (FLOOR-MOUNTING) STRUCTURES STRUCTURES FUNCTIONAL DIM. (LxH) 600x1600mm 600x1800mm 600x2000mm 850x1600mm 850x1800mm 850x2000mm Modular capacity Pitch 150mm 240 mod.  (24x10) 288 mod.  (24x12) 312 mod.  (24x13) 240 mod.  (24x10) 360 mod.  (36x10) 288 mod.  (24x12) 432 mod.  (36x12) 312 mod.  (24x13) 468 mod.  (36x13) Pitch 200mm 192 mod.  (24x8) 216 mod.  (24x9) 240 mod.  (24x10) 192 mod.  (24x8) 288 mod.  (36x8) 216 mod.  (24x9) 324 mod.  (36x9) 240 mod.  (24x10) 360 mod.  (36x10) Structures GW 45 057 GW 45 058 GW 45 059 GW 45 067 GW 45 068 GW 45 069 Solid side panels GW 45 077 GW 45 078 GW 45 079 GW 45 077 GW 45 078 GW 45 079 Aerated side panels GW 45 397 GW 45 398 GW 45 399 GW 45 397 GW 45 398 GW 45 399 Curved glass doors GW 45 157 GW 45 158 GW 45 159 GW 45 167 GW 45 168 GW 45 169 Solid doors GW 45 177 GW 45 178 GW 45 179 GW 45 187 GW 45 188 GW 45 189 Internal cable   compartment - - - GW 45 087 GW 45 088 GW 45 089 Side-by-side   installation kit Plates GW 47 472 GW 47 472 GW 47 472 GW 47 472 GW 47 472 GW 47 472 IP55  Gasket GW 47 473 GW 47 473 GW 47 473 GW 47 473 GW 47 473 GW 47 473 EXTERNAL CABLE COMPARTMENT FUNCTIONAL DIM. (LxH) 400x1600mm 400x1800mm 400x2000mm External cable compartment GW 45 097 GW 45 098 GW 45 099 Internal solid doors GW 45 352 GW 45 353 GW 45 354 External solid doors GW 45 197 GW 45 198 GW 45 199

COMPLEMENTARY ITEMS Depth adapter GW 49 209 Pair of hinges GW 45 532 Pair of supports for wiring trunking GW 45 521 Pair of supports for horizontal terminal block GW 45 526 Pair of supports for vertical terminal block GW 45 527  (internal cable compartment) GW 45 528  (external cable compartment) DIN profiles  L = 2 metres EN 50022 (DIN35) GW 47 691 EN 50035 (G32) GW 47 692 EN 50024 (C30) GW 47 693 IP43 gasket for CVX 630 K GW 47 494 Rotating handle with key GW 47 494 4 surface-mounting brackets for CVX 630 K wall-mounting boards GW 45 536 2 surface-mounting brackets for CVX 630 M floor-mounting boards GW 47 491 (1) Specific version for MTX/M 160c, MTX/E 160, MTX/M 250, combined with an “L” shaped add-on residual current device. CONFIGURATION FOR CVX 630 K - M BOARDS Panel height (mm) L= 400mm (10 mod.) L= 600mm (24 mod.) L= 850mm (36 mod.) Installation kit  on DIN rail DIN EN 50022  double - aluminium 150 GW 45 291 GW 45 201 GW 45 206 200 GW 45 292 GW 45 202 GW 45 207 300 GW 45 293 GW 45 203 GW 45 208 300 (1) - GW 45 204 GW 45 209 Solid front  panels 50 GW 45 341 GW 45 301 GW 45 321 100 GW 45 342 GW 45 302 GW 45 322 150 GW 45 343 GW 45 303 GW 45 323 200 GW 45 344 GW 45 304 GW 45 324 300 GW 45 345 GW 45 305 GW 45 325 400 GW 45 346 GW 45 306 GW 45 326 600 GW 45 347 GW 45 307 GW 45 327 800 GW 45 348 - - Front panels  for instruments 200 - GW 45 374 GW 45 379 Front aerated  panels 200 - GW 45 362 GW 45 367 DIN rails DIN EN 50022  double - aluminium - - GW 45 401 GW 45 402 Profiles for  fixing directly  on frame DIN EN 50022 - - GW 45 411 GW 45 416 DIN EN 50035 - - GW 45 412 GW 45 417 Back-mounting plates 200 - GW 45 421 GW 45 431 300 GW 45 406 - - 400 - GW 45 422 GW 45 432 600 - GW 45 423 GW 45 433 Earth terminal blocks - GW 45 537 GW 45 538 - Earth busbar - - GW 45 534 GW 45 535 Horizontal dividers - - GW 45 453 GW 45 454 H B 46 Distribution boards up to 630A CVX 630 K - M range

A complete software suite for the design, budgeting and  certification of the GEWISS range. Software Choice of the most suitable Smart [4] for your system, and payback calculation Budgeting and thermal assessment of enclosures (CEI 23-51) Budgeting of DOMO CENTER flush-mounting system columns for distribution, domotics and data Software for choosing the ReStart automatic reset devices Web software Software for the design and budgeting of electrical systems. This program is interconnected with the other GEWISS software packages, allowing you to manage the graphic elements (symbols, images, drawings, etc.) of the components contained in projects processed by other GEWISS programs. Application for automatically updating the GEWISS software. START START Software for controlling and managing the GEWISS programs.Shows all the characteristics of the various software packages by means of descriptions, images and video courses, to facilitate your choice. Software for the lighting design of indoor and outdoor environments, and for creating the supporting documentation for the client. Software for the design, sizing and budgeting of systems and BT boards. Also allows the user to obtain the design of the board front and check its thermal capacity. Software for the budgeting of the complete electrical system. Can be used autonomously, or importing the data processed by the other GEWISS programs. € € Software for creating tender specifications for electrical systems in relation to various application contexts that can be selected by the user. Software for the certification and budgeting of worksite boards, boards for wharfs and campsites, and distribution boards, with the possibility to automatically draw up the necessary technical documentation. Software for the design and budgeting of video entryphone systems, with the possibility to define the device connection layout. Software for defining the “Performance level” of the electrical system in residential contexts, based on the latest version of Standard CEI 64-8. Software for drawing up the documentation for the Declaration of Conformity (certifying that the system is up to standard) (Ministerial Decree 37/08 - CEI 0-3). Contains all the references to the main quality marks relating to all the GEWISS products. 37/08 37/08 Software for managing DXF drawings relating to GEWISS products, and inserting them in AutoCad or GWCAD. Software for the economic assessment of street lighting systems using the GEWISS ranges Avenue 1, 2 and 3 for street categories from ME1 to ME6, in accordance with the requisites of Standard UNI EN 13201-2. Software for the design and budgeting of BUS systems, with the possibility to define the layout and the correct addressing/connection of the BUS devices. Software for the quick design and budgeting of video entryphone systems. A simple wizard helps the user choose the main system parameters. 47

GEWISS S.p.A. Registered office: Via A. Volta, 1 - 24069 CENATE SOTTO (Bergamo) - Italy  Tel. +39 035 946 111 - Fax +39 035 945 222 - [email protected] - www.gewiss.com  Sole Shareholder company - Bergamo Register of Companies / VAT/Tax code (IT) 00385040167 - REA 107496 - Share capital 60,000,000.00 EUR fully paid up PB 90017 EN - 02.15