Schneider Electric - Product catalogue - Panelbuilder MV Brochure - 2014
Components for Medium Voltage cubicles 2013 The widest range of components to meet your requirements
True peace of mind
Easy to source, continuous and worldwide availability Due to Schneider Electric’s presence in more than 100 countries, you can be sure of finding the range of products and devices to meet your needs and comply with local standards. Easy to integrate Benefit from our tools and training package to increase your product knowledge and ensure easy integration, allowing you to be more efficient in your business.All necessary information on mounting and assembly is supplied with each component. Fully type-tested products Compliant with the latest international and local standards Tools for your business performance: • Drawings• Configurators• Technical manuals (user guides, installation manuals...) • Products catalogues• Maintenance guides and End of life manuals Schneider Electric commitments High quality components Based on our expertise in building Medium Voltage cubicles, all the proposed components are designed to be fully consistent with the others.This gives an assurance of complete interoperability, which has been tested in our own Medium Voltage cubicles equipped with these components.Moreover, our industrialised processes and quality controls guarantee the highest level of component quality to meet your most demanding expectations. Compatible with Smart Grid application Given the demand for an increasing number of energy production sources and the increasingly significant obligations of network adaptability, operators have to know, understand and act correctly:• Know the switchboard's status at all times• Act with full knowledge of the factsMedium-voltage switchboards demand more and more remote measurement and control capabilities.You will therefore find a whole range of latest-generation monitoring and control devices which fully complement our Medium Voltage switching devices.
Schneider Electric a brand you can trust
Schneider Electric a brand you can trust Our common values : • Quality• Safety• Professionalism 5% of sales devoted to R and D Schneider Electric’s policy has always been to provide its customers with support in their daily activities to enable them to achieve operational excellence. In this overview, Schneider Electric presents to you all the components that you may need to build your Medium Voltage cubicle, from Medium Voltage to Low Voltage. The experience of a world leader in Medium Voltage Schneider Electric has been manufacturing MV cubicles for more than 50 years and its installed base amounts to millions of products and devices.The Schneider Electric brand is known worldwide and recognised by the most demanding customers. A long history of innovation for a global offer Based on its experience as a world leader, Schneider Electric has developed a large and comprehensive range of innovative Medium Voltage devices employing vacuum, air and SF6 technology. With the first multi-functional digital protection relay created in 1982, you have the benefit of a global leader's experience and know-how in electric distribution, automation and power and control.All the devices included in this overview have been designed and manufactured to incorporate the benefits of this extensive experience. Quality certification: ISO 9001 and ISO 14001 In each of its units, Schneider Electric has an operating organisation whose main role is to verify quality and ensure compliance with standards. This procedure is:• uniform for all departments• recognised by numerous customers and official organisations The quality system for design and manufacturing is certified in compliance with the requirements of the ISO 9001 Quality Assurance model. There are always Schneider Electric people close to you: 150000+ people in more than 100 countries! Local support all over the world. Benefit from Schneider Electric’s expertise
The widest range of components to meet your requirements
Contents Medium Voltage Components panorama Medium Voltage switching devices A-1 Protection, Metering and Remote control B-1 Power Factor Correction C-1 Accessories D-1 DE90206 DE90209
A-0
Medium Voltage switching devices Circuit-Breakers Contactors Switches and Disconnectors Fuses Medium VoltageComponents panorama DE90206_1 Circuit-Breakers - Contactors - Switches and Disconnectors - Fuses - Protection relays - Arc fault detectors - MV instrument transformers - Energy management and control - LV protection - Direct Current Power supply - LV relays - LV Control and Signalling - Substation remote control and monitoring and Fault indicators - Substation power supply - Capacitors and Power Factor controller - Relay and Switching devices - Accessories A-1 A-2A-4A-6A-7
Medium Voltage switching devices Circuit-Breakers Benefits Embedded pole for better dielectric and environmental pollution withstand Embedded pole for better dielectric and environmental pollution withstand • Compact dimensions • Reliable spring mechanism for open pole technology PE90236 DE90217 PE57994 A-2 HVX - Embedded pole Evolis Protection and operation of network 40.5 kV 36 kV 24 kV 17.5 kV 17.5 kV 12 kV 12 kV 50 kA 50 kA 31.5 kA 31.5 kA 31.5 kA 31.5 kA 31.5 kA 3150 A 3150 A 3150 A 2500 A 2500 A 2500 A 2500 A • Fixed • Withdrawable • Fixed • Withdrawable • Fixed • Withdrawable 3p 3p 3p 10000 10000 10000 10000 Front Front Front Conventional spring Conventional spring Conventional spring IEC, GB (chinese) standards IEC, GB (chinese), GOST standards IEC standards
Benefits Embedded pole for better dielectric and environmental pollution withstand Embedded pole for better dielectric and environmental pollution withstand • Compact dimensions • Reliable spring mechanism for open pole technology A-3 SF6 Circuit Breakers LF SF1 SF2 Functions Protection and operation of network Rated voltage 40.5 kV 36 kV 36 kV 24 kV 17.5 kV 17.5 kV 12 kV 12 kV Max. rated short-circuit current 50 kA 40 kA 25 kA 25 kA 25 kA 25 kA 40 kA 31.5 kA Max. rated current 3150 A 3150 A 1250 A 1250 A 1250 A 1250 A 3150 A 2500 A Versions • Fixed • Withdrawable • Fixed • Fixed• Withdrawable Number of poles 3p 3p 3p Mechanical switching cycles (ON/OFF) 10000 10000 10000 Mounting Front • Front • Side Front Mechanism Conventional spring Conventional spring Conventional spring IEC standards IEC standards IEC standards PE57191 PE90232 PE56501 Benefits • Suited for nuclear powerplant• Marine solutions certified • Integrated VIP trip unit (without auxiliary power supply) in SFset up to 24 kV (for side mounted)• Suited for capacitor bank application High energy mechanism (230 J) to open at high voltage ratings HVX - Embedded pole Evolis Protection and operation of network 40.5 kV 36 kV 24 kV 17.5 kV 17.5 kV 12 kV 12 kV 50 kA 50 kA 31.5 kA 31.5 kA 31.5 kA 31.5 kA 31.5 kA 3150 A 3150 A 3150 A 2500 A 2500 A 2500 A 2500 A • Fixed • Withdrawable • Fixed • Withdrawable • Fixed • Withdrawable 3p 3p 3p 10000 10000 10000 10000 Front Front Front Conventional spring Conventional spring Conventional spring IEC, GB (chinese) standards IEC, GB (chinese), GOST standards IEC standards
A-4 Medium Voltage switching devices Contactors Vacuum contactors SF6 contactor CPX CLX CBX CVX Rollarc Functions Functions Protection and control of network Protection and control of network Rated voltage Rated voltage 12 kV 12 kV 12 kV 7.2 kV 7.2 kV 7.2 kV 7.2 kV 3.6 kV Max. rated short-circuit current Max. rated short-circuit current 4 kA 6 kA 6 kA 4 kA 6 kA 4 kA 10 kA 8 kA Max. rated current Max. rated current 400 A (AC4) 400 A (AC4) 400 A (AC4) 315 A (AC4) 400 A (AC4) 315 A (AC4) 400 A (AC4) 400 A (AC4) Versions Versions • Fixed • Fixed • Fixed • Withdrawable CBX version equipped with DIN or BS fuses• Optional on board auxiliary voltage transformer • Withdrawable CBX version equipped with DIN or BS fuses • Fixed • Withdrawable Number of poles Number of poles 3p 3p 1p - 3p 3p 3p 3p Mechanical switching cycles (ON/OFF) Mechanical switching cycles (ON/OFF) 250 000 (mechanical latch) and 1 000 000 (magnetically held) 250 000 (mechanical latch) and 1 000 000 (magnetically held) 250 000 (mechanical latch) and 3 000 000 (magnetically held) 250 000 (mechanical latch) and 1 000 000 (magnetically held) 250 000 (mechanical latch) and 1 000 000 (magnetically held) 100 000 (mechanical latch) and 300 000 (magnetically held) Mechanism Mechanism Magnetic or mechanical latch Magnetic or mechanical latch Magnetic or mechanical latch Magnetic or mechanical latch Magnetic or mechanical latch Magnetic or mechanical latch IEC standards IEC standards IEC, GB (chinese) standards IEC, GB standards IEC, GB standards IEC standards 50 kA in conjunction with fuses PE90531 PE90244 PE90243 Benefits Special version available for capacitor banks Front access to terminals Special version available for capacitor banks • High short circuit breaking capacity in combination with fuses• LV supply thanks to optional on board VT High short circuit breaking capacity in combination with fuses Reference product in SF6 contactor market, Nuclear powerplant application, Capacitor bank application PE90532 PE90245
A-5 Vacuum contactors SF6 contactor CPX CLX CBX CVX Rollarc Functions Functions Protection and control of network Protection and control of network Rated voltage Rated voltage 12 kV 12 kV 12 kV 7.2 kV 7.2 kV 7.2 kV 7.2 kV 3.6 kV Max. rated short-circuit current Max. rated short-circuit current 4 kA 6 kA 6 kA 4 kA 6 kA 4 kA 10 kA 8 kA Max. rated current Max. rated current 400 A (AC4) 400 A (AC4) 400 A (AC4) 315 A (AC4) 400 A (AC4) 315 A (AC4) 400 A (AC4) 400 A (AC4) Versions Versions • Fixed • Fixed • Fixed • Withdrawable CBX version equipped with DIN or BS fuses• Optional on board auxiliary voltage transformer • Withdrawable CBX version equipped with DIN or BS fuses • Fixed • Withdrawable Number of poles Number of poles 3p 3p 1p - 3p 3p 3p 3p Mechanical switching cycles (ON/OFF) Mechanical switching cycles (ON/OFF) 250 000 (mechanical latch) and 1 000 000 (magnetically held) 250 000 (mechanical latch) and 1 000 000 (magnetically held) 250 000 (mechanical latch) and 3 000 000 (magnetically held) 250 000 (mechanical latch) and 1 000 000 (magnetically held) 250 000 (mechanical latch) and 1 000 000 (magnetically held) 100 000 (mechanical latch) and 300 000 (magnetically held) Mechanism Mechanism Magnetic or mechanical latch Magnetic or mechanical latch Magnetic or mechanical latch Magnetic or mechanical latch Magnetic or mechanical latch Magnetic or mechanical latch IEC standards IEC standards IEC, GB (chinese) standards IEC, GB standards IEC, GB standards IEC standards 50 kA in conjunction with fuses PE60247 Benefits Special version available for capacitor banks Front access to terminals Special version available for capacitor banks • High short circuit breaking capacity in combination with fuses• LV supply thanks to optional on board VT High short circuit breaking capacity in combination with fuses Reference product in SF6 contactor market, Nuclear powerplant application, Capacitor bank application
A-6 Medium Voltage switching devices Switches and Disconnectors SF6 Switch and Disconnector Air Switch and Disconnector Withdrawable earthing and disconnector trucks LBSkit L-TRI5 Earthing truck Disconnector truck Functions Indoor load break switch, disconnector and accessories Indoor load break switch, disconnector The earthing truck is a safety feature which allows the cubicle busbar to be earthed.It is installed instead of the circuit breaker and has the same interlock possibilities The disconnector truck enables the upper and lower part of the cubicleto be short-circuited. It is installed instead of the circuit breaker andhas the same interlock possibilities Rated voltage Refer to respective Circuit Breaker range and ratings Refer to respective Circuit Breaker range and ratings 36 kV 36 kV 24 kV Max. rated short-circuit current 25 kA 25 kA 20 kA 20 kA 20 kA Max. rated current 630 A 1250 A 630 A 1600 A 2500 A IEC standards IEC standards DE56784 PE90386 DE56785 PE90384 Benefits • Unaffected to environment• Reduced maintenance Air technology Interchangeability ensured with equivalent circuit-breaker rating Interchangeability ensured with equivalent circuit-breaker rating
A-7 Fuses Current limiting fuses Fusarc CF Solefuse Tepefuse MGK Functions Protection to Medium Voltage distribution devices (from 3.6 to 36 kV) from both the dynamic and thermal effects of short-circuit currents Rated voltage 36 kV 36 kV 24 kV 24 kV 24 kV 17.5 kV 12 kV 12 kV 12 kV 7.2 kV 7.2 kV 7.2 kV 3.6 kV Max. rated current Up to 200 A Up to 125 A Up to 0.3 A Up to 250 A Max. rated short-circuit current Up to 63 kA Up to 50 kA Up to 40 kA Up to 50 kA Applications • Motors• Power Transformers• Capacitors• Voltage Transformers • Power Transformers• Capacitors Voltage Transformers Motors IEC 60282-1, DIN 43625, VDE 0670-402 IEC 60282-1, UTE C64200, C64210 IEC 60282-1, UTE C64200, C64210 IEC 60282-1, UTE standards PE90383 Benefits • High breaking capacity• High current limitation• Low I2t values• Low breaking overvoltage• Low dissipated power• Indoor and outdoor applications• With a thermal striker
B-0
Protection, Metering and Remote control Protection relays Arc fault detectors Medium Voltage instrument transformers Energy management and control Low Voltage protection Direct Current power supply Low Voltage relays Low Voltage control and signalling Substation remote control and monitoring and fault indicators Substation power supply Medium VoltageComponents panorama DE90206_2 Circuit-Breakers - Contactors - Switches and Disconnectors - Fuses - Protection relays - Arc fault detectors - MV instrument transformers - Energy management and control - LV protection - Direct Current Power supply - LV relays - LV Control and Signalling - Substation remote control and monitoring and Fault indicators - Substation power supply - Capacitors and Power Factor controller - Relay and Switching devices - Accessories B-1 B-2 B-4 B-5 B-6B-9 B-10 B-11 B-12 B-16 B-17
Protection, Metering and Remote control Protection relays B-2 Protection relays Sepam series 10 MiCOM Px10 Sepam series 20 Sepam series 40 Vamp 50 series MiCOM Px20 Sepam series 60 Sepam series 80 MiCOM Px30 Functions Functions Provides protection of network for each applications: Substations (incomer or feeder type) / Transformers / Motors / Generators / Busbars / Capacitors (capacitor protection relay page C-3). Each relays serie offers all the functions required for:• effective protection of life and property• accurate measurements and detailed diagnosis• integral equipment control• local or remote indications and operation Self power / Auxiliary supply Self power / Auxiliary supply Auxiliary supply • Auxiliary supply• Self or Dual supply Auxiliary supply Auxiliary supply Auxiliary supply Auxiliary supply Auxiliary supply Auxiliary supply Auxiliary supply Protection Protection Current (1 or 5 A) Current (1 or 5 A) • Current (1 or 5 A)• Voltage • Current (1 or 5 A)• Voltage • Current (1 or 5 A)• Voltage • Current (1 or 5A)• Voltage • Current (1 or 5 A or LPCT)• Voltage • Current (1 or 5 A or LPCT)• Voltage • Current (1 or 5A)• Voltage Phase and Earth basic Phase and Earth basic Phase and Earth basic - Phase and Earth basic - Directional - Phase and Earth basic - Directional - Phase and Earth basic - Directional - Phase and Earth basic - Directional - Synchro-check - Phase and Earth basic - Directional - Synchro-check - Differential - Phase and Earth basic - Directional - Synchro-check - Differential - Line differential - Distance Display Display Standard UMI Standard UMI • Standard UMI• Remote UM • Standard UMI• Remote UM Standard UMI Standard UMI • Standard UMI• Remote UM• Mimic based UMI • Standard UMI• Remote UM• Mimic based UMI • Standard UMI• Remote UM• Mimic based UMI Other characteristics Other characteristics Withdrawable hardware Withdrawable hardware Removable S/W cartridge Removable S/W cartridge Input / Output (up to) Input / Output (up to) 4 / 7 6 / 6 10 / 8 10 / 8 7 / 5 7 / 8 28 / 16 42 / 23 50 / 26 I/O terminals I/O terminals Screw type Screw type • Screw type• Ring lug • Screw type• Ring lug Ring lug Ring lug • Screw type• Ring lug • Screw type• Ring lug • Screw type• Ring lug Temperature sensor (up to) Temperature sensor (up to) 8 8 to 16 External RTD input module 10 (motor) 8 to 16 8 to 16 1 / 9 / 10 Communication protocol Communication protocol • Modbus RTU• IEC 60870-5-103 • Modbus RTU• IEC 60870-5-103 • Modbus RTU• IEC 60870-5-103• DNP3• Modbus TCP/IP• IEC 61850 No GOOSE • Modbus RTU• IEC 60870-5-103• DNP3• Modbus TCP/IP• IEC 61850 No GOOSE• RSTP • Modbus TCP / RTU • Profibus DP• IEC 60870-5-101 • IEC 60870-5-103 • IEC 61850 with goose• DNP3• SPA-bus communication • DeviceNet • Modbus RTU• IEC 60870-5-103• DNP3 • Modbus RTU• IEC 60870-5-103• DNP3• Modbus TCP/IP• IEC 61850 Standard GOOSE• RSTP • Modbus RTU• IEC 60870-5-103• DNP3• Modbus TCP/IP• IEC 61850 Customised GOOSE• RSTP • Modbus RTU• IEC 60870-5-103• DNP3• IEC 61850 with GOOSE• RSTP / SHP / DHP Logic equations Logic equations Comprehensive logic equations Basic logic equations Comprehensive logic equations Control logic by ladder diagram Comprehensive logic equations Safety characteristics Safety characteristics Arc flash protection IEC 61508 - SIL2 IEC 61508-SIL2 IEC and specific country standards(UL, CSA, GOST...) IEC and specific country standards(GOST...) IEC and specific country standards(UL, CSA, GOST...) IEC and specific country standards(UL, CSA, GOST...) IEC and specific country standards(UL, CSA, GOST...) IEC and specific country standards (GOST...) IEC and specific country standards(UL, CSA, GOST...) IEC and specific country standards(UL, CSA, GOST...) IEC and specific country standards (GOST...) Ethernet high availability communication PE90366 PE90623 PE90624 PE90510 PE90511 PE90511 PE90625
Benefits Sepam• Hardware modularity and common Hardware modules• Large range of auxiliary power• Full range ROHS and conformal coated MiCOM• Complete and Comprehensive product offer• Full IEC 61850 solution with goose• All in the box solution Vamp 50• Powerful CPU supporting native IEC 61850 • Improved safety with economical and fast arc flash protection B-3 Protection relays Sepam series 10 MiCOM Px10 Sepam series 20 Sepam series 40 Vamp 50 series MiCOM Px20 Sepam series 60 Sepam series 80 MiCOM Px30 Functions Functions Provides protection of network for each applications: Substations (incomer or feeder type) / Transformers / Motors / Generators / Busbars / Capacitors (capacitor protection relay page C-3). Each relays serie offers all the functions required for:• effective protection of life and property• accurate measurements and detailed diagnosis• integral equipment control• local or remote indications and operation Self power / Auxiliary supply Self power / Auxiliary supply Auxiliary supply • Auxiliary supply• Self or Dual supply Auxiliary supply Auxiliary supply Auxiliary supply Auxiliary supply Auxiliary supply Auxiliary supply Auxiliary supply Protection Protection Current (1 or 5 A) Current (1 or 5 A) • Current (1 or 5 A)• Voltage • Current (1 or 5 A)• Voltage • Current (1 or 5 A)• Voltage • Current (1 or 5A)• Voltage • Current (1 or 5 A or LPCT)• Voltage • Current (1 or 5 A or LPCT)• Voltage • Current (1 or 5A)• Voltage Phase and Earth basic Phase and Earth basic Phase and Earth basic - Phase and Earth basic - Directional - Phase and Earth basic - Directional - Phase and Earth basic - Directional - Phase and Earth basic - Directional - Synchro-check - Phase and Earth basic - Directional - Synchro-check - Differential - Phase and Earth basic - Directional - Synchro-check - Differential - Line differential - Distance Display Display Standard UMI Standard UMI • Standard UMI• Remote UM • Standard UMI• Remote UM Standard UMI Standard UMI • Standard UMI• Remote UM• Mimic based UMI • Standard UMI• Remote UM• Mimic based UMI • Standard UMI• Remote UM• Mimic based UMI Other characteristics Other characteristics Withdrawable hardware Withdrawable hardware Removable S/W cartridge Removable S/W cartridge Input / Output (up to) Input / Output (up to) 4 / 7 6 / 6 10 / 8 10 / 8 7 / 5 7 / 8 28 / 16 42 / 23 50 / 26 I/O terminals I/O terminals Screw type Screw type • Screw type• Ring lug • Screw type• Ring lug Ring lug Ring lug • Screw type• Ring lug • Screw type• Ring lug • Screw type• Ring lug Temperature sensor (up to) Temperature sensor (up to) 8 8 to 16 External RTD input module 10 (motor) 8 to 16 8 to 16 1 / 9 / 10 Communication protocol Communication protocol • Modbus RTU• IEC 60870-5-103 • Modbus RTU• IEC 60870-5-103 • Modbus RTU• IEC 60870-5-103• DNP3• Modbus TCP/IP• IEC 61850 No GOOSE • Modbus RTU• IEC 60870-5-103• DNP3• Modbus TCP/IP• IEC 61850 No GOOSE• RSTP • Modbus TCP / RTU • Profibus DP• IEC 60870-5-101 • IEC 60870-5-103 • IEC 61850 with goose• DNP3• SPA-bus communication • DeviceNet • Modbus RTU• IEC 60870-5-103• DNP3 • Modbus RTU• IEC 60870-5-103• DNP3• Modbus TCP/IP• IEC 61850 Standard GOOSE• RSTP • Modbus RTU• IEC 60870-5-103• DNP3• Modbus TCP/IP• IEC 61850 Customised GOOSE• RSTP • Modbus RTU• IEC 60870-5-103• DNP3• IEC 61850 with GOOSE• RSTP / SHP / DHP Logic equations Logic equations Comprehensive logic equations Basic logic equations Comprehensive logic equations Control logic by ladder diagram Comprehensive logic equations Safety characteristics Safety characteristics Arc flash protection IEC 61508 - SIL2 IEC 61508-SIL2 IEC and specific country standards(UL, CSA, GOST...) IEC and specific country standards(GOST...) IEC and specific country standards(UL, CSA, GOST...) IEC and specific country standards(UL, CSA, GOST...) IEC and specific country standards(UL, CSA, GOST...) IEC and specific country standards (GOST...) IEC and specific country standards(UL, CSA, GOST...) IEC and specific country standards(UL, CSA, GOST...) IEC and specific country standards (GOST...) Ethernet high availability communication PE90622 PE90488 PE90512
Protection, Metering and Remote control Arc fault detectors Benefits • Personnel safety• Reduces production losses• Extended switchgear life cycle• Reduced insurance costs• Low investment costs and fast installation• Reliable operation B-4 Arc fault detector Vamp 120 Vamp 121 Vamp 221 (+I/0 units) Vamp 321 (+I/0 units) Functions The arc protection unit detects an arc flash in an installation and trips the feeding breaker.An arc flash protection maximises personnel safety and minimises material damage caused by arc faults System features • Typical operation on light only principle - Input for current criteria for I and L operation - Integrated 19 - 256 V AC/DC aux. supply • Optimised for wind power and other small applications • Up to 4 arc or smoke sensors • Selective trip for 2 zones and possibility for generator set emergency trip (separate contact) • Operation time 7 ms (including the output relay) • Non-volatile trip status • NO and NC trip outputs (Zone 1) - Self-supervision - Straight-forward installation - Cost efficient solution • Operation on light only • Up to 10 sensors arc or smoke sensors • Single trip contact • Straight-forward installation • Operation time 9 ms (including the output relay) • Cost efficient solution • Self-supervision • Binary input for blocking or resetting (programmable) the unit • Possibility for double arc channel activation trip criteria • BIO light transfer possibility to other Vamp device • Current and light tripping criteria (possibility of tripping by light only)• Operating time 7 ms or less (electromechanical contact)• Accurate location of arc fault utilising point sensors• Four selective protection zones per central unit• Self-supervision of the entire system• Easy interconnect using VX001 cables• Phase current measuring• Earth fault current measuring• Personal protector option• Panel or rail mount I/0 units• Circuit breaker fail protection (CBFP) • Three phase current, zero sequence voltage and current• Event logs, disturbance recording and real time clock• Operation on simultaneous current and light or light only• Informative display LCD (single line diagram)• Up to ten trip contacts• One normally open and one change over alarm contact• Less than 7 ms operation time (including the output relay)• Optionally 1 ms operation time when semi-conductor outputs are used• Programmable operation zones• Continuous system self supervision• PC configurable• Communication ports supporting a wide range of communication protocols which are intended for a SCADA interface Sensors Point sensor - surface Point sensor - surface Point sensor - surface - Arc detection from two compartements simultaneously - Self-monitored - Cable length adjustable from 6m to 20m down - Arc detection from two compartements simultaneously - Self-monitored - Cable length adjustable from 6m to 20m down - Arc detection from two compartements simultaneously - Self-monitored - Cable length adjustable from 6m to 20m down Point sensor - pipe Point sensor - pipe Point sensor - pipe - Self-monitored - Cable length adjustable from 6 to 20m down - Self-monitored - Cable length adjustable from 6 to 20m down - Self-monitored - Cable length adjustable from 6 to 20m down Portable sensor Portable sensor - Snap-in connection to I/0 unit - Enhanced work safety - Snap-in connection to I/0 unit - Enhanced work safetyLoop sensor (fibre)- Monitors various compartments - Small bending radius for easy installation IEC standards IEC standards IEC standards IEC standards I/0 units: 4 ref. available (VAM 3L, VAM 10L/LD, VAM 12L/LD, VAM 4C/CD). The choice is to be made according to the needs of type and number of sensors. Please contact us. PE90501 PE90502 PE90503 PE90626 VAM 3L VAM 10L VAM 12L VAM 4C VAM 3L VAM 10L VAM 12L VAM 4C
B-5 Current Transformers Voltage Transformers Low Power Current Transformers CT VT LPCT Functions For protection or metering purpose Allows protection and metering in the same product. Both are achieved in the same winding Rated voltage 40.5 kV 40.5 kV 24 kV 0.72 kV Max. rated short-circuit current 60 kA 50 kA 50 kA 50 kA 40 kA Max. rated current Max. rated voltage Max. rated current 5000 A 2500 A 2500 A 36 kV 1250 A 2500 A Technology MV insulation technology for MV applications LV insulation tech. for MV applications Main characteristics • PX accuracy class can be respected in accordance to the relay formula.• CT types available with primary winding (wounded or bar type) or without primary winding (toroid or window type).• Ratio change (tapping) on primary or secondary side according to CT types. • Available types for connection between phases or between phase and earth.• Voltage factor 1.9Um x 8h (phase-earth) or 1.2 Um continuously (phase-phase)• Rated primary voltage up to 35:√3 kV (phase-earth) or 35 kV (phase-phase) • Suitable for applications in earthed or insulated neutral systems.• Available types with metal screened surface according to application Rated nominalsecondary voltage22.5 mV. Rated nominalsecondary voltage 22.5 mV Insulation Class A (covering and insulation realized by vacuum casting EPOXY resin and APG technology with excellent electrical characteristics, high mechanical strength and high ageing resistance) IEC and specific country standards(IEEE, NBR, NFC, GOST…). IEC and specific country standards(IEEE, NBR, NFC, GOST…). IEC 60044-8 IEC 60044-8 Outdoor offer is also available. Please contact us. Protection, Metering and Remote control Medium Voltage instrument transformers Benefits • Wide range also available folllowing DIN standard• Lack of emissions of any harmful substances in case of fire Operating safety: no danger in the event of any accidental opening of the secondary circuit Can be installed in 24 kV, 36 kV or 40.5 kV networks without any specific MV insulation PE90296 PE90298 PE90529 PE90302 PE90303 PE90299 PE90300
Protection, Metering and Remote control Energy management and control Energy metering Power and Energy monitoring AMP - ammeter VLT - voltmeter PM3255 PM710 PM750 Functions Measures in amps the current flowing through an electrical circuit Measures in volts the potential difference (voltage) of an electrical circuit Offers the basic measurement capabilities required to monitor an electrical installation Offers all the measurement capabilities required to monitor an electrical installation • Flush mounted 72x72 - 96x96• 10 A direct currentmeasurement orvia external CT• Accuracy: class 1.5 • Flush mounted 72x72 - 96x96• 600 V AC directvoltage measurementor via external VT• Accuracy: class 1.5 • 5-module case (18 mm modules)• Energy accuracy: IEC 62053-21 class 1 • Panel front mounted 96x96• Energy accuracy: - PM710: IEC 62053-21 class 1- PM750: IEC 62053-22 class 0.5S Instantaneous rms values • Current, per Phase and Neutral• Voltage: Total, Phase-to-Neutral and Phase-to-Phase• Frequency• Power factor: Total • Active, reactive, partial active energy • Multi-tariff management • Current: Total, per Phase and Neutral• Voltage: Total, Phase-to-Neutral and Phase-to-Phase• Frequency• Power factor: Total - Signed• Active, reactive, partial active energy: Signed Power quality measurements THD Current, voltage Total harmonic distortion: Current, voltage, per phase Data recording • Min/Max/Demand values• Alarms• Data logging • Min/Max of instantaneous values• Alarms Communication • Modbus RS485 protocol • 2 digital inputs• 1 digital output Modbus RS485 protocol • Modbus RS485 protocol• 2 digital inputs• 1 digital output Display • Backlit LCD • Multi-language HMI LCD (features large 11 mm high characters and powerful backlighting for easy reading even in extreme lighting conditions viewing angles) IEC 60051-1, IEC 61013-1, IEC 61000-4 IEC 61557-12 PMD/S-/K55/1 IEC 62053-21 class 1IEC 61557-12 PMD/S/K55/1 IEC 62053-22 class 0.5SIEC 61557-12 PMD/S/K55/0.5 Benefits Local measurements • Panel instrumentation• Sub-billing / cost allocation• Remote monitoring of an electrical installation • Panel instrumentation• Sub-billing / cost allocation• Remote monitoring of an electrical installation• Harmonic monitoring (THD) PB101118 PE90491 PB108435 PE86157 B-6
B-7 Power and Energy monitoring Advanced energy metering PM820 PM850 PM870 ION7550 ION7650 Functions • Offers high-performance capabilities needed to meter and monitor an electrical installation• Comprehensive Power Quality Analysis • Offers unmatched functionality including advanced power quality analysis coupled with revenue accuracy• Flexible architecture for extensive user programmability • 96 x 96 mm DIN or Panel mount. RTU, integrated or remote display • Direct connection up to 600 Vac (no PTs) • Built in digital input and output. Additional I/Os optional • Energy Accuracy - ANSI 12.20 Class 0.2 and IEC 62053-23 Class 0.5S • 192 x 192 mm Panel mount • Five current and four voltage inputs (physical) • I/O options available • Revenue Class 0.2 grade metering Instantaneous rms and energy values Comprehensive RMS values or instrumentation Advanced RMS values or instrumentation • Active, reactive, apparent energy• Configurable accumulation mode • Active, reactive, apparent energy• Configurable accumulation mode Power quality measurements Individual harmonics (harmonic resolution up to the 63rd) - Current and Voltage • Harmonic resolution up to the 63rd. Interharmonics up to the 50th (ION7650 only)• Individual harmonics - Current and Voltage• Waveform capture of voltage disturbances with disturbance direction detection • Waveform capture (PM870: configurable)• EN50160 - ITI(CBEMA)/SEMI F-47• Power Quality compliance evaluation Sag and swell detection • Power quality compliance evaluation • Flicker detection Data recording • Min/max values with data and event logs• GPS synchronisation• Alarms with e-mail notification • Min/max values with data and event logs• GPS synchronisation• Alarms with e-mail notification• Trending / forecasting• Memory up to 10 MB Trending / forecasting80 kB memory 300 kB memory Communication • Built in Modbus RS485• Optional RS232 and second RS485 ports• Optional Ethernet port with gateway functionality and web server Extensive communications options and protocols.Serial RS232/485, Optical, Modem and/or Ethernet (gateway and web server) ports, Modbus RTU, DNP 3.0, Modbus TCP/IP, IEC 61850 or ION Display White backlit LCD display. Intuitive navigation with self-guided, language-selectable menus Programmable display. Integral LCD or remote color ANSI 12.20 Class 0.2, IEC 61557-12, ANSI C37.90.1 Surge Withstand Capability (SWC) and IEC 61000-4-12 Surge Immunity standards + many other international standards IEEE 519, IEEE 1159 and CBEMA/ITIC IEC 61000-4-30 Class A, IEC 61000-4-7 and IEC 61000-4-15 PE86149 PE86158 Protection, Metering and Remote control Energy management and control Benefits • For infrastructure, industrial and buildings • Highly accurate• Modular • Energy cost allocation and savings• Energy availability and reliability • For infrastructure, industrial, buildings and utilities • Revenue metering• Flexible architecture and programmability• Energy savings• Leverage existing infrastructure• Energy availability and reliability
Protection, Metering and Remote control Energy management and control Communication EGX100 EGX300 Functions Ethernet gateway• Serves as an Ethernet coupler for PowerLogic system devices and other communicating devices using the Modbus protocol• Offers complete access to status and measurement information provided by connected devices via PowerLogic PC-based software Web-enabled integrated gateway-server• Simplifies power utility monitoring: historical use patterns, which come from real-time electrical system loading data and trend plots, help optimise energy usage and existing electrical infrastructure• Monitors energy usage patterns, reveals opportunities, and helps verify results of efficiency improvements• Remotely monitors real-time conditions and profile energy use on your power distribution system DIN rail mounted Characteristics • Web interface allows for configuration, diagnostics and maintenance• Secure user interface via user name and password• User interface available in English, French, German and Spanish• Supports serial master to ModbusTCP/IP routing• Advanced security through ModbusTCP/IP filtering with configurable access levels (read-only or full access)• Receives control power through Power over Ethernet (PoE) or 24 Vdc power source• Includes one 10/100Base-Tx Ethernet port• RS485 2-wire and 4-wire compatibility• IP30-rated DIN rail mounted enclosure• Rated for use in industrial environments (-25 to 70°C) • View real-time and historical information from multiple locations via any Microsoft-compatible web browser; no need for additional software• Automatically email or FTP selected logged data to your PC for additional analysis• Select the logging intervals and topics you want logged.• Ensures data and system security through password protection and controlled network access to individual web pages and allows review of active and historical connections• Receives control power through Power over Ethernet (PoE) or 24 VDC power source• Provides serial support for Modbus RTU, Modbus ASCII, Jbus and PowerLogic protocols to support a wide range of devices.• Optically isolated serial port provides highly reliable communications in an industrial environment• Includes one 10/100BaseTx Ethernet port• Includes one serial port configurable for RS485 (2-wire or 4-wire) or RS232 (RJ45)• Compatible with all PowerLogic power monitoring software Communication • RS232 or RS485 (2-wire or 4-wire), depending on settings with Modbus RTU/ASCII, PowerLogic (SY/MAX), Jbus protocols• 10/100 Base TX Ethernet port with HTTP, Modbus TCP/IP, FTP, SNMP (MIB II) and BootP (EGX300 only) protocols• Web interface for configuration, diagnostics and maintenanceEN 610000, IEC 60950, UL508/UL60950, CSA C22.2, EN 60950, AS/NZS25 60950, EN55022/EN55011/FCC class A standards PowerLogic software Ethernet Modbus TCP/IP Ethernet Modbus TCP/IP Modbus RS485 serial link ION6200 ION6200 PM800 PM800 Micrologic Micrologic Sepam Sepam EGX100 gateway EGX300 integrated gateway- server EGX300 web pages Benefits • Simplifies installation by receiving control power through the Ethernet cable• Set up via an Ethernet network or a serial connection.• TCP/IP filtering security allows you to specify the level of access each master has to connected serial devices• Serial Master Support allows a serial Modbus master device connected to the gateway's serial port to access devices across a TCP/IP network• Compact DIN-rail mounted product • Simplifies installation by receiving control power through the Ethernet cable• Automatically detects networked devices for easy set-up• Allows creation of custom web pages; use web pages to view the real-time and logged data for an at-a-glance view of your energy consumption• Dashboards display energy consumption information aggregated over time• System Access Point shows networked Schneider Electric devices PE90492 DE90211 DE90212 B-8
B-9 Protection, Metering and Remote control Low Voltage protection Low Voltage protection C60N C60HDC C60 Electrical auxiliairies OF SD Functions DIN rail miniature circuit-breakers. Circuit-Breaker used in auxiliary power supply circuits providing overload and short circuit protection Open/closed contact Fault signalisation contact Rated voltage 12 to 240 VAC (Ph/N) 250 VDC/pole • 24...415 VAC• 24...130 VDC Number of poles 1, 2, 3, 4 1 or 2 Breaking capacity 10 kA at 240 VAC 6 kA at 250 VDC Nominal current Maximum operating current 0.5 to 63 A • 6 A at U ≤ 240 VAC and 3 A at U ≤ 415 VAC• 6 A at U = 24 VDC, 2 A at U ≤ 48 VDC, 1 A at U ≤ 130 VDC Type ol loads/ Tripping curve B, C, D C Connection Screw IEC 947-2 Tripping Curve Type of loads C (5In Im 10In) Standard D (10In Im 14In) Inrush current B (3In Im 5In Electronics or high cable length Benefits The Multi9 circuit-breaker is recognised in over 100 countries for its quality and the breadth of its range, making it an indispensable component for your Low Voltage cabinet with complete peace of mind PB104014 PE90505 PE90504 PB100221 054047_SE
Protection, Metering and Remote control Direct Current Power Supply Direct Current power supply Phaseo ABL8REM, ABL7RP ABL4RS ABL4WS ABL8RP ABL8WP Functions The electronic switch mode power supply is designed to provide the direct current voltage necessary for automation system equipment control units Rated input voltage 100 to 240 V AC 100 to 240 V AC 400 to 500 V AC 100 to 500 V AC 400 to 500 V AC Input type 1 phase 1 or 2 phases 3 phases 1 or 2 phases 3 phases Output voltage and current • 12 V DC / 5 A• 24 V DC / 3 A and 5 A• 48 V DC / 2.5 A 24 V DC / 3.5 A, 5 A, 10 A, 20 A 24 V DC / 20 A, 30 A, 40 A 24 V DC / 3 A, 5 A, 10 A, 20 A 24 V DC / 20 A, 40 A Power output 72 to 144 W 85 to 960 W 85 to 960 W 72 to 960 W 72 to 960 W IEC standards IEC standards IEC standards IEC standards IEC standards ABL4 and ABL8 only available in some countries Benefits Compact size • Compact size• Removable terminals• Diagnosis relay • Compact size• Diagnosis relay • Wide input volatge (100 - 500 VAC)• Power boost• Manual or automatic reset mode• Advanced diagnostic • Power boost• Manual or automatic reset mode• Advanced diagnostic PF106463 ABL4RSM24100 ABL4WSR24200 PE90167 PE90169 B-10
Protection, Metering and Remote control Low Voltage relays Electromechanical plug-in relays Zelio relays Miniature relays RXM Universal relays RUM Functions Designed for the adaptation, amplification, multiplication and processing of information in automated system Switching voltage 12/250 VAC/DC Number of contacts 2, 3 or 4 CO 2 or 3 CO Current 6 - 10 - 12 A 10 A Mounting Plugs into socket (DIN rail)IEC 61984-1 PE90199 PE90200 Benefits • Wide choice of number of contacts (up to 4)• Simplicity of installation and maintenance• Standardisation of relay pin arrangement on its socket.• TEST button for checking the relay functions, even in a remote enclosure• Clear indication: contact status mechanical indicator and RELAY ON @LED indicator• Suitable input/output currents and switching voltages B-11
Protection, Metering and Remote control Low Voltage Control and Signalling Pushbuttons and Switches ZB6/XB6 XB7 ZB5/XB5 ZB4/XB4 K1/K2 Functions Enables operation of the Low Voltage circuits of the Medium Voltage cubicle Mounting hole (mm) 16 22 16/22 Material Plastic Metallic Plastic or metallic Head shape Composition type Modular Unibody Modular Panel fixing with Plastic nut 3 points metal Plastic nut or 4 screws Degree of protection IP 65 IP 65 IP 66 IP 66 IP 40 / IP 65 Rated insulation voltage 250 V 250 V 600 V 600 V 690 V UL/CSA, IEC UL/CSA, IEC UL/CSA, IEC, CCC, GOST UL/CSA, IEC, CCC, GOST UL/CSA, IEC 109865 PF094400 107756 103060 107435 107747 PF569141 107439 107406 107395 107426 103515 101449 107433 107600 103502 Benefits • Easy to select and to install• A wide choice of functions• Robustness and mechanical durability• High protection degree• Excellent aesthetics and ergonomics B-12
Illuminated Pushbuttons, Pilot lights and Switches XVL ZB6/XB6 XB7 ZB5/XB5 ZB4/XB4 Functions Provides status information and enable control of Low Voltage circuits Mounting hole (mm) 8/10/12 16 22 Material Plastic Metallic Head shape Composition type Unibody Modular Unibody Modular Panel fixing with Plastic nut 3 points metal Degree of protection IP 40 / IP 65 IP 65 IP 65 IP 66 IP 66 Rated insulation voltage 50 V 250 V 250 V 600 V max 600 V max UL/CSA, IEC UL/CSA, IEC UL/CSA, IEC, CCC, GOST UL/CSA, IEC, CCC, GOST UL/CSA, IEC, CCC, GOST 107417 107416 107418 107436 PF100400 PF569141 107751 107432 107429 110030 PF569150 PF106192 Benefits • Long life resistance (LED technology)• True colours and excellent brightness• A wide choice of voltages• High protection degree• Easy mounting B-13
Protection, Metering and Remote control Low Voltage Control and Signalling Selector switches CMA CMV Functions CMA uses a single ammeter (by means of Current Transformers) for successive measurement of the currents of a three-phase circuit CMV uses a single voltmeter for successive measurement of voltages (phase-to-phase and phase-to-neutral) of a three-phase circuit 48 x 48 Flush mounted 48 x 48 Flush mounted Mechanical switching cycles 2 000 000 Electrical switching cycles 100 000 Max. rated voltage 500 V Max. rated current 20 AIEC 60947-3 N 1 2 3 4 3 A CMA S1 S2 S1 S2 S1 S2 4 10 2 3 9 1 3 O L3-1 L2-3 L1-2 L3-N L2-N L1-N 1 2 3 4 230 V N L V L3 L2 L1 N 12 10 6 2 • AgNi contact ensuring mechanical durability• IP65 on front face PE90493 PE90494 B-14
Protection, Metering and Remote control Low Voltage Control and Signalling New Linergy TR - Terminal Blocks Cable Ends NSY TRV NSY TRR NSY TRP DZ5 / AZ5 Functions Ensures connection of Low Voltage cables or wires • Facilitates the insertion of wires into the terminals and assures the insulation between adjacent connection• Allows the identification of the wires Technology Screw clamp technology Spring clamp technology Push-in technology Insulated cable ends Connection functions • Passthrough (2.5 - 250 mm²)• Protective earth• Disconnect type (blade or fuse)• Double deck, multi-pole• Multifunction• Neutral disconnect • Passthrough (2.5 - 16 mm²)• Protective earth• Disconnect type (blade or fuse)• Double deck, multi-pole • Passthrough (1 - 2.5 mm²)• Protective earth• Disconnect type (blade or fuse)• Double deck, multi-pole Three available versions:• Single conductor cable ends• Single conductor markable cable ends• Twin conductor cable ends Conductor nominal c.s.a. (cross section area) 2.5 mm² to 240 mm² 2.5 mm² to 16 mm² 2.5 mm² and 4 mm² 0.25 mm² to 50 mm² Number of poles 1 - 1 x 1 / 1 - 2 x 2 2 - 1 x 1 / 3 - 1 x 1 1 - 1 x 1 / 1 - 1 x 2 / 1 - 2 x 22 - 1 x 1 / 2 - 1 x 2 / 3 - 1 x 1 1 - 1 x 1 / 1 - 1 x 2 / 1 - 2 x 22 - 1 x 1 / 2 - 1 x 2 / 3 - 1 x 1 Clip-on mounting on rail type UL, CSA, VDE, ATEX UL, CSA, VDE, ATEX UL, CSA, ATEX UL, CSA available from January 2013 Benefits Rugged and reliableThis technology not only provides quality, safety and availability of equipment but optimises installation setup and operation with their simple integrated functions Cost effective (quick and reliable)Spring technology is a maintenance-free connection method assuring separation of mechanical and electrical functions. It also eliminates the need for regular re-tightening Quick and innovativeSolid conductors or conductors with cable-ends can be directly inserted into the terminal block without tools.The actuation lever can be operated with any tool for loosening conductors Fast and reliable wiringDon’t forget the AZ5 and DZ5 ranges of cable ends to simplify wiring and provide optimum electrical continuity between wire and terminal block. 817449_2 817449_1 PE90495 B-15 PE90628 PE90630 PE90632 PE90629 PE90631
Substation remote control and monitoring units EasergyT200I Flair 200C Functions • Provides switch remote monitoring and control• Option for Automatic Trans-fer System (ATS) using Voltage Presence Information from VD23 (see D-2) Provides remote access to fault detection and data monitoring of the substation • Capacity: 1-16 switches• Battery autonomy: 16 h• Fault indicator: phase and earth fault• Uninterruptible power supply: 24 or 48 Vcc• Option for IEC 61131 programming languages to develop automation functions • One or two Fault Indicators:phase and earth fault for all types of neutral arrangement• Integrated functions of measurement and monitoring of the substation and data transmission• Option for IEC 61131 programming languages to develop automation functions Protocols IEC 870-5-101 and 104, DNP3/DNP3 IP, Modbus/Modbus TCP and various customer owned protocols Transmission systems • Ethernet, RS232/485, radio, PSTN, GSM, GPRS• Periodic call management• Concentration of Modbus slave devices• Embedded web server• Local and remote configuration IEC standards IEC standards available from April 2013 Protection, Metering and Remote control Substation remote control and monitoring and fault indicators PE90513 PE90443 PE90444 PE90445 All-In-One device:- reliability- single configuration and diagnostic tool • All-In-One device:- reliability- single configuration and diagnostic tool• Opens the door to the most advanced Smart grid monitoring needs • Easy commissioning • Highly configurable• Long life time• Measurement functions included• Advanced fault detection features • Configurable fault detection settings• Ten years life time battery B-16 Fault Passage Indicators (FPI) EasergyFlair 21D-22D-23D-23DM Flair 219-279 Functions Provides phase and earth fault local indicationAmmetric FPI, self powered by measurement sensors, integrated in MV switchgear or in wall-mounted box Ammetric FPI, powered by LV supply and/or battery, wall-mounted installation Detection Phase and earth fault Setting By dip switches or menu on LCD display By dip switches Installation Embedded in the switchgear Wall mounted Earthing system Direct, impedant, compensated, isolated Supply Self powered by current sensor (+ Li battery on Flair 22D) • Flair 279: 230V AC + Li battery• Flair 219: Li battery Measurement • Ammeter• Maxmeter Communication • Dry output contact (Flair 21D-22D-23D)• Modbus RS485 (23DM) Dry output contact IEC standards IEC standards
Protection, Metering and Remote control Substation power supply Substation power supply Easergy PS100 Functions The PS100 associated with a back-up battery ensures the ininterrupted power supply up to 48 hours in the event of micro-outage and power interruptions for: • MV switchgear electrical mechanism ( motors and coils ) • Transmission equipment ( e.g. radio ) • Protection relays , Fault passage indicators or others IEDS • And all others devices in MV/LV substations (Low Voltage breakers, PLC concentrator..) Power supply outputs • 12 VDC - 100 W / 20 s (for modem, radio, RTU, etc) and 18 W permanent• 48 VDC or 24 VDC - 300 W / 1 minute (for switchgear operating mechanism motors) and 90 W permanent (for protection relays, electronic devices, etc) Protocols ModbusIEC 60255-5 (10 kV level) standard PM100615 • Transmission equipment such as radios• Control units such as Remote Terminal Units (RTU) or Automatic Transfer Systems (ATS)• Protection relays, Fault Passage Indicators and other Intelligent Electronic Devices (IED)• Robustness to the environment of a substation (10 kV insulation, -40° C + 70° C operating temperature)• Additional ENERGY BACK-UP to restart the installation after a prolonged network cut• Modbus communication port forwards monitoring data to allow optimised maintenance operations• Limitation, dedicated to radio units, to avoid the battery discharge B-17
Energy efficiency with Power Factor Correction Most utilities have specific policies for billing reactive energy. Price penalties are applied if the active power / apparent power ratio is not within the guidelines. Power Factor Correction solutions modify and control the reactive power to avoid utility penalties and reduce overall kVA demand. These solutions result in lowering utility power bills by 5 to 10%. C-0
Power Factor Correction Capacitors and Power Factor controller Relay and Switching devices Medium VoltageComponents panorama Circuit-Breakers - Contactors - Switches and Disconnectors - Fuses - Protection relays - Arc fault detectors - MV instrument transformers - Energy management and control - LV protection - Direct Current Power supply - LV relays - LV Control and Signalling - Substation remote control and monitoring and Fault indicators - Substation power supply - Capacitors and Power Factor controller - Relay and Switching devices - Accessories DE90210 C-1 C-2C-3
Power Factor Correction Capacitors and Power Factor controller Capacitors Power Factor controller Propivar NG Varlogic NR6 - NR12 - NRC12 Functions Propivar capacitors are used to build capacitor banks for power factor correction on medium voltage networks Measures the reactive power of the installation and controlconnection and disconnectionof capacitor steps in order toobtain the required power factor Maximum Voltage Um (kV) • NR6 - Control up to 6 capacitor steps• NR12 - Control up to 12 capacitor steps• NRC12 - Control up to 12 capacitor stepsand offer some more functionsand Modbus 36 kV 24 kV 17.5 kV 12 kV 7.2 kV Basic Impulse Level (BIL) (kV peak) 60 75 95 125 170 Technical specifications They allow by their different assembly combination to cover many power ratings depending on the insulation voltage, frequency and harmonic pollution level of the network• Single capacitor• 3 phase capacitor• Surge protection• Double capacitor unit • Panel mounting on 35 mm DINrail (EN 50022).• Insensitive to phase rotationpolarity.• Direct display of networkand capacitor bank stepcharacteristics• Automatic programmingand commissioning• Communication option Modbus RS485 network Maximum nominal reactive power 900 kvar (1p) - 600 kvar (3p) - 800 kvar (double capacitor unit)IEC 60871-1, 2 and 4, NEMA CP1.Other standards on request IEC 61326 (CEM), IEC 61010-1/EN 61010-1 standards PE90516 PB10032_SE Benefits • Safety: all Propivar NG capacitors are type tested• Reliability: 30 years design life• Green: no PCB full compliance with ROHS directive • Simplification of the installation,supervision and maintenanceof reactive power compensationequipment• Intuitive man/machine dialogue C-2
Power Factor Correction Capacitors and Power Factor controller Relay and Switching devices Benefits • Compliance with RoHS European directive • Low Energy consumption C-3 Protection relays Sepam series C86 Fonction Protection relay dedicated to capacitor application Self power / Auxiliary supply Auxiliary supply Protection • Current (1 or 5 A or LPCT)• Voltage- Phase and Earth basic - Directional - Synchro-check - Differential Display • Standard UMI• Remote UM• Mimic based UMI Other characteristics Removable S/W cartridge Input / Output (up to) 42 / 23 I/O terminals • Screw type• Ring lug Temperature sensor (up to) 8 to 16 Communication protocol • Modbus RTU• IEC 60870-5-103• DNP3• Modbus TCP/IP• IEC 61850 Customised GOOSE• RSTP Logic equations Control logic by ladder diagram Safety characteristics IEC 61508 - SIL2IEC standards Ethernet high availability communication Switching devices adapted to capacitor applications Circuit - Breakers • SF1 and SF2• HVX Contactors • Rollarc• CBX (specific version)• CPX (specific version up to 3.6 kV) PE90512
D-0
Accessories Medium VoltageComponents panorama DE90206_3 Circuit-Breakers - Contactors - Switches and Disconnectors - Fuses - Protection relays - Arc fault detectors - MV instrument transformers - Energy management and control - LV protection - Direct Current Power supply - LV relays - LV Control and Signalling - Substation remote control and monitoring and Fault indicators - Substation power supply - Capacitors and Power Factor controller - Relay and Switching devices - Accessories D-1
Accessories Accessories Sepam 100MI VPIS V2 and phase concordance unit VD23 Insulating holder w or w/o capacitive divider Functions Module with animated mimic diagram and selector switch / pushbutton for local or remote control, showing the cubicle single line diagram with devices symbolised • Self-powered Voltage Presence Indicating System• Including voltage output version (VPIS-VO) for connection to a VD23 Voltage presence relay• Needs Phase Concordance Unit for Phase concordance checking • Indicates presence or absence of voltage through 1 or 2 relays• For MV networks from 3 kV to 36 kV• Associated with VPIS-VO • Without capacitive divider: provides mechanical support and insulation through their rigid fin arrangement; used to support busbars and cable ends• With capacitive divider: provides mechanical support and insulation. The embedded capacitors in this insulating holder provide voltage output to indicate the voltage presence, up to 24 kV Technical specifications • Available in 14 standards types• 21-pin connector on the back for the connection of - supply voltage-device position indication output-circuit breaker control (open/close and disconnect) outputs.• Power supply: 24 to 127V AC/DC • Connectors on the front panel allowing to use a Phase Concordance Unit • Light indication using LEDs• Made in 2 parts: surge protection part, always connected and Voltage presence indication part, replaceable for maintenance • Self-adapted to network Voltage• Displays the voltage in % of nominal• Output contacts behaviour configurable according to various combinations of phase and unbalance voltage status• DIN format• Allows to address various applications: - Automatic transfer systems- Alarms on voltage loss- Automation on voltage loss- Earth locking on voltage presence- Alarms on voltage presence • Height: 175 mm• Capacitive divider: ISO 35 pf Reference numbers Each module is suited to a particular indication and local control application chosen according to:• Cubicle single-line diagram• Devices whose positions are to be indicated• Required local control functions • 4 versions according to voltage ranges:- VPI624x3 (2 kV-4 kV)- VPI624x4 (3 kV-6.3 kV)- VPI624x7 (9 kV-17 kV)- VPI624x8 (13 kV-25 kV)with 2 ref. for each version: - x=0 for VPIS- x=1 for VPIS-VO• Phase concordance unit: VPI62421 • Voltage presence relay (VD23): ref. EMS58421• Combined voltage presence relay + Fault Passage Indicator (Flair 23DV): ref. EMS58353 • 3 isolateurs standards :- 17.5 kV ref. 59431 - 24 kV ref. AAA10075• 3 isolateurs avec diviseurs capacitifs : - 17.5 kV ref. 59430 - 24 kV ref. AAA10074 IEC standards IEC 62271-206 IEC standards IEC standards PE90500 PE90514 PE90515 PE56830 Benefits • Includes all the animated mimic elements for viewing, breaking and disconnection devices status• Compact size and easy installation• Reduced cabling• Stand-alone or with Sepam High reliability thanks to:• Harsh environment design• LED indication: extended life time • Fits all MV network neutral systems• Compact (DIN format)• Output contact behaviour highly configurable according to configuration needs • Dielectric withstand• Mechanical robustness D-2 PE58141
AccessoriesAnti-condensation Heating element Insulation busbar cover High resistance plastic window Cubicle compartment handle Extraction table Functions Heating the inside of the cubicle when the ambient temperature is too low Set of 3 insulating covers which enables improved dielectric withstand at the busbars connections in the cubicle Located on the panel or the door, allows you to see inside a cubicle Enables the front panel door of the cubicle to be closed. Enables the circuit-breaker to be taken out of the cubicle and handled during maintenance operations or cubicle manufacturing Technical specifications • 220 V AC• 150 W• Length: 432 mm • Supplied with its support without thermostat For 1 to 4 busbars (100 m x 800 mm each) • 3 mm thick transparent Polycarbonate window• Dimensions:138 mm x 85 mm • Material: Zamak• A version with key is available • Height adjustment up to 250 mm• A latching device is provided between the extraction table and the cradle Reference numbers 59280 59420 59105 • 59270 (handle)• 59271 (handle with key) Available for respective circuit-breakers ranges.• For Evolis:- 59130 (full extraction table)- 59129 (top tray of the table + full device drawings for local manufacturing)• For other circuit-breakers, please contact us DE90207 DE90213 DE90214 DE90216 DE56927 Avoid condensation in the cubicle Can be adjusted according to number of busbars Internal arc withstand up to 31.5 kA Robustness Possibility to manufacture locally the table support frame D-3
UK contact details - 0870 608 8 608 Fax 0870 608 8 606 Ireland contact details - 01 601 2200 Fax 01 601 2201 As the global specialist in energy management with operations in more than 100 countries, Schneider Electric offers integrated solutions across multiple market segments, including leadership positions in energy and infrastructure, industrial processes, building automation and data centres/ networks, as well as a broad presence in residential applications. Schneider Electric is dedicated to making individuals’ and organisations’ energy safe, reliable, efficient, productive and green from Power Plant to Plug TM . We are changing our brand names and becoming one Schneider Electric. You’ll get the same great quality products, but from one name you can remember and trust. This provides you and your customers with the reassurance associated with Schneider Electric. Some of our market leading brands have already become Schneider Electric including Merlin Gerin, Telemecanique, Square D, GET, Mita, Sarel, Himel, Thorsman, Tower and TAC. Working as one Schneider Electric makes it clearer that our ranges are highly compatible for integrated solutions. Schneider Electric Ltd Schneider Electric Limited is a company registered in England and Wales. Registered number: 1407228. Registered office: Stafford Park 5, Telford, Shropshire TF3 3BL. © 2013 Schneider Electric. All Rights Reserved. Schneider Electric, Active Energy Management, Compact, EcoStruxure, ION Enterprise, iRIO, Make the most of your energy, Masterpact, Micrologic, Power Plant To Plug, Modbus and PowerLogic are owned by Schneider Electric Industries SAS, or its affiliated companies in the United States and other countries. As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication. NRJED111211EN-V2 SE8249 NOV 2013 United KingdomStafford Park 5, TelfordShropshire TF3 3BLTel: 0870 608 8 608Fax: 0870 608 8 606www.schneider-electric.com/uk IrelandHead office, Block aMaynooth Business CampusMaynooth, Co. KildareTel: (01) 601 2200Fax: (01) 601 2201www.schneider-electric.com/ie member of