Peterborough Football Club - Flex Connectors - Case Study - 2016
flex7

Peterborough Football Club - Flex Connectors - Case Study - 2016

flex7 Lighting connection and control products have been used in the recent £9.5m redevelopment of The Moy’s End Stand at Peterborough United football stadium.

Peterborough  Football Club Leisure flex7 Lighting connection and control products have been used in the recent  £9.5m  redevelopment  of  The  Moy’s  End  Stand  at  Peterborough  United  football  stadium.  The  project  includes  a  3000sqm  specialist  education  centre, linked to the stand. The building was designed to reach a BREEAM excellent standard.

Absence control flex7 absence and daylight linking lighting control was installed throughout the building. flex7 absence sensors  save energy by turning lights off once an area has been occupied for a pre-determined period of time. This  length of time can be programmed using a setup remote control.  Daylight linking control flex7 daylight linking controls are programmed to adjust lights up or down, to take full advantage of natural  daylight. They will dim the lights up or down as daylight changes, to maintain a constant (preset) light level in  a room. Control packs simply plug in to any flex7 eZeBox connection unit. Emergency key switch The consultant requested a local emergency key switch with manual dimming and absence control in all  offices, store rooms and WC areas. A flex7 dimmable control unit with integrated emergency test facility  was used, which plugs directly into any of the eZeBox range of connection units or a 7-pole single socket  outlet. Working with a switch or together with a sensor head, the device controls the connected mains rated  luminaires ON/OFF and is able to carry out an emergency test. Any connected switch or sensor head will  operate at PELV. f l e x c o n n e c t o r s T r a c k i n g   =   2 7 7 Only 1 switch drop was needed to control both dimming and emergency switching in any room where an  fnc2000/E was used. Because the fnc2000E operates at protected extra low voltage, it does not need to be  enclosed, or require an RCD to be compliant with the 17th edition wiring regulations. Why use flex7? flex7 products were chosen because of the flexibility of the product range and because the system is pre-fab-ricated, which ensured quick and easy installation on site. Photo credits: Ben Kirkpatrick Flex Connectors Ltd Ruscombe Business Park Ruscombe Lane Twyford RG10 9LR t: 020 8580 1066 [email protected]

Published: 14 April 2016 Category: Case studies

Topics