Categories
Features
|
Duplex
|
-
|
|
Weight
|
9.999
|
|
AWG size
|
-
|
|
Category
|
Other
|
|
EFDE0051
|
-
|
|
EFFR0001
|
false
|
|
EFFR0002
|
false
|
|
EFUK0022
|
-
|
|
EFUK0023
|
-
|
|
EFUK0024
|
-
|
|
NVP value
|
-
|
|
Stranding
|
-
|
|
Cable type
|
-
|
|
Drain wire
|
-
|
|
UV resistant
|
yes
|
|
With rip cord
|
-
|
|
Cable geometry
|
Round
|
|
Number of cores
|
4
|
|
Conductor surface
|
Bare
|
|
Nominal voltage U
|
-
|
|
Protective sheath
|
-
|
|
Stranding element
|
No
|
|
Conductor category
|
Class 5 = flexible
|
|
Conductor material
|
-
|
|
Diameter conductor
|
-
|
|
Material armouring
|
Other
|
|
Cable width approx.
|
-
|
|
Colour outer sheath
|
Grey
|
|
Core identification
|
Colour
|
|
Cable height approx.
|
-
|
|
Material outer sheath
|
Polyurethane (PUR)
|
|
Screen over stranding
|
None
|
|
Outer diameter approx.
|
6.2
|
|
With rodent protection
|
-
|
|
Armouring/reinforcement
|
-
|
|
Number of sheath layers
|
-
|
|
Characteristic impedance
|
-
|
|
Material core insulation
|
-
|
|
Radial water blocking cable
|
-
|
|
Suitable as telephone cable
|
no
|
|
Number of stranding elements
|
-
|
|
Suitable as signalling cable
|
no
|
|
Screen over stranding element
|
None
|
|
Specification core insulation
|
Polyethylene (PE)
|
|
Nominal cross section conductor
|
0.75
|
|
Suitable as computer data cable
|
no
|
|
Longitudinal water blocking cable
|
-
|
|
Certified for shipboard application
|
no
|
|
Specification material outer sheath
|
-
|
|
Low smoke according to EN IEC 61034-2
|
-
|
|
Suitable for underground installation
|
-
|
|
Halogen free according to EN IEC 60754-1
|
-
|
|
Halogen free according to EN IEC 60754-2
|
-
|
|
Halogen free according to EN IEC 60754-3
|
-
|
|
Suitable for use as security alarm cable
|
-
|
|
Approved type of underground installation
|
Other
|
|
Max. tensile strength during installation
|
-
|
|
Segregation class according to EN 50174-2
|
C
|
|
Core identification according to HD 308 S2
|
no
|
|
Flame retardant according to IEC 60332-1-2
|
-
|
|
Circuit integrity according to IEC 60331-23
|
-
|
|
Oil resistant according to EN IEC 60811-404
|
-
|
|
Reaction-to-fire according to EN 13501-6: Class
|
-
|
|
Reaction-to-fire according to EN 13501-6: Acidity
|
-
|
|
Flame retardant according to IEC 60332-3-22 (Cat A)
|
-
|
|
Flame retardant according to IEC 60332-3-23 (Cat B)
|
-
|
|
Flame retardant according to IEC 60332-3-24 (Cat C)
|
-
|
|
Flame retardant according to IEC 60332-3-25 (Cat D)
|
-
|
|
Flame retardant according to IEC 60332-3-21 (Cat A F/R)
|
-
|
|
Reaction-to-fire according to EN 13501-6: Smoke production
|
-
|
|
Permitted cable outer temperature during assembling/handling
|
-30 - 80
|
|
Min. permitted bending radius, moving application/free movement
|
-
|
|
Permitted cable outer temperature after assembling without vibration
|
-30 - 80
|
|
Reaction-to-fire according to EN 13501-6: Flaming droplets/particles
|
-
|
|
Min. permitted bending radius, moving application with forced guidance
|
-
|
|
Min. permitted bending radius, stationary application/permanent installation
|
-
|