Read an rcd - Voltimum - Search | | Results of your search | Results 1 - 10 About 2680 For read an rcd (0.67 Seconds) | | | | I was reading the installation instructions for a shower I was installig and it said the shower should be protected by a 30mAmp RCD. The wiring regulations dont make it a requirement so which takes priority? IEE or manufacturer | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | | | | when installing additional socket outlets to a circuit and all bonding conductors are present and the Zs readings are ok, do you need to install an RCD? say when installing in a conservatory or downstairs circuit | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | | | | .(INSIDE THE PROPERTY) 1. The maximum Ze reading for P.M.E is 0.35 2. But if all circuits in the property are RCD protected is the reading I have of 0.55 ok.? [...] | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | | | | are the only circuits protected by RCD and the rest of my Zs readings are what I would expect.All bonding is present and correct but I can't understand these two readings - can you please [...] | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | | | | What would be the correct way to rectify a problem with high Zs readings found during a periodic test & inspection of a domestic installation. The Ze reading was fine, but a few radial [...] | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | | | | We have been asked to connect a machine to a generator supply ( generator 264KVA 3 phase with loop reading of 0.09 ohms) do we need to install an rcd and earth electrode at genarator ? what precautions do we need to consider [...] | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | | | | How do you test Double Pole RCD's in science labs that have 55v on each leg. I think they are 10ma. It is a question that puzzles me. We can trip it but due to the voltage we can not get any readings. Is there something we are missing | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | | | | Is the attached equation correct in relation to using an RCD/MCCB combined on a construction site? On a test certificate the section for maximum zs would read 250 ohms for a setting of 100ma | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | | | | HI, Thank,s for the last info . I guess with reference to the O.S.G section 11 (11.5) it should read exceeds 40Ms not (In less than)40Ms, Thank,s again.B.C | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | | | | of the 'off' main switch, with both RCDs and breakers off I get the >500 reading, as soon as I switch the first RCD on, all breakers still off I get a reading of 365vdc and 0.28Mohms, that [...] | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | |
|
|
|