Metering - Voltimum - Search | | Results of your search | Results 71 - 80 About 1270 For metering (0.81 Seconds) | | | | A roll - out programme to introduce smart electricity meters into consumers' homes starts in 2012[...] smart electricity meters into consumers' homes in 2012. The programme is expected to run through until 2020 with the aim of helping customers | | http://www.voltimum.co.uk/news/15073/s/Smart-electricity-met[...] | | | | | Assuming we are working in the Domestic world, If the incoming tails are allowed to be 3 meters max. Is this 3 meters after the tails come out of the Service fuse enclosure ?Then one must fit a switch fuse, if the Consumer Unit is further away | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | | | | I may have to install meter tails as part of a new build project. The distance from the new CCU to the outside meter is approximately 5m so how would you suggest that the meter tails are run. There is a possibility that I may be able | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | | | | A dwelling in which I am working has meter tails of a smaller diameter than the 25mm sample I take[...] of the copper conductor of my 25mm sample. Two questions: 1) What size meter cable do you think I have encountered here? 2) What is the minimum | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | | | | Sirs A block of six flats, has six gas meters, all external in the normal wall boxes, section 4[...], or at point of entry to the building if service meter is external. Is there a limit, to the length of pipe from the meter, to the point | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | | | | If a set of 2m long meter tails are installed in a domestic situation, for example straight down[...] the wall into a meter enclosure, how do they comply with BS7671 522.6.6? Is there any exemption to meter tails or do they require installing | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | | | | Could you explain the requirements for metering laid out in Part l of the Building Regulations 2006? I know there is reference made to separately meter mechanical loads, [...] | | http://www.voltimum.co.uk/consult.php?action=main&mode=consu[...] | | | | | Plinths cannot be used when meter modules are fitted/extension boxes | | http://www.voltimum.co.uk/catalog/prod/ABU-ZL1000/prod-P/FOU[...] | | | | | Flat travelling PVC cables for elevators, for indoorapplications, with a freely suspended length up to 50 meters | | http://www.voltimum.co.uk/catalog/fam/NEU-/003/006/NEU-0191/[...] | | | | | Flat travelling PVC cables for elevators, for indoorapplications, with a freely suspended length up to 75 meters | | http://www.voltimum.co.uk/catalog/fam/NEU-/003/006/NEU-0201/[...] | | |
|
|
|