17th Edition requirements for the testing of RCDs

2008-04-23
IEE
 

The 17th Edition of the Wiring Regulations (BS 7671: 2008) will introduce a number of new requirements for the installation of RCDs, therefore it is timely to look at the requirements within the 17th Edition for verification of RCDs.

17th Edition requirements for the testing of RCDs
pixel

The continuing effectiveness of these RCDs needs to be confirmed periodically. This article discusses the verification required where RCDs are used to provide automatic disconnection of supply in the event of a fault and additional protection. It should be stated at this point that the 17th Edition does not introduce any significant changes in the requirements for the testing of RCDs even where they are installed to provide automatic disconnection in the event of a fault.

Use of RCDs to achieve automatic disconnection in case of a fault 411.3.2.1 requires (in most cases) that a protective device shall interrupt the supply to a line conductor of a circuit or equipment in the event of a fault of negligible impedance between said line conductor and an exposedconductive- part or a protective conductor for the circuit or equipment within the appropriate required disconnection time. A disconnection time of 5 seconds for distribution equipment and final circuits of rating exceeding 32A is permitted by 411.3.2.3. Similarly, a disconnection time of 1 second for distribution equipment and final circuits of rating exceeding 32 A is permitted by 411.3.2.4.

To read the full article, please see attachment below.

Originally published in Wiring Matters, Spring Edition 2008, written by Jon Elliott


 Back

 Downloadable attachment(s)
bluearrow  Read the Full Article (981kb)

 Related contacts
The Institution of Engineering and Technology
Michael Faraday House
Stevenage
Herts
SG1 2AY
UK
Tel: +44 (0)1438 313 311
Fax: +44 (0)1438 765 526

 For latest electrical industry news, register for Voltimum's free newsletter.
Enter your email address here:
OK

Source: IET

Related information

Downloadable attachment(s)
Related contacts

More News...

Periodic inspection or planned maintenance?
Appendix 4 of BS 7671
Section 559 luminaires and lighting installations - An overview
17th Edition Training
IEE Ring final circuit meeting
Supplementary equipotential bonding
Requirements for cables concealed in a wall or partition – A brief overview
Protection against Electric Shock