Prysmian protects cancer research findings at UCL

01.10.2007
Prysmian
 

University College London’s new Institute for Cancer Studies is using Prysmian’s FP200 Gold fire performance cable to help ensure the safety of over 350 scientists involved in critical research.



UCL's Institute for Cancer
UCL's Institute for Cancer
pixel

The 14 month-long development houses researchers investigating aspects of cancer prevention, early detection, basic biology and novel therapeutics. The £35 million research centre in Bloomsbury, London covers five floors, plus a basement and roof plant control rooms, and employs FP200 Gold cable to power the extensive analogue addressable fire alarm systems.

With the security and safety of the researchers and their work being paramount, Chelmsford-based contractor Fisk Fire Group had no doubts over which cable to use.

Tel Fisk, senior estimator, explains: “We always use Prysmian because it is the market-leading brand and we know it is proven to meet the requirements of BS5839-1:2002, which is crucial when installing essential life-saving systems.

There is no viable alternative to rival FP200 Gold. The closest is MICC but it’s harder to work with and less cost effective, as additional time and labour is required for the installation.”

FP200 Gold was installed in cable tray and the smooth installation process was made even easier with the application of Prysmian’s AP7 cable clips. “From a practical point of view the cables look good once installed, providing a clean finish to complement the building’s contemporary design,” Tel Fisk added.

For further information email cables.marketing.uk@prysmian.com


If you like this article and want to share it with friends, please use the social links below:

 Back

 Related links
blue arrow pointing right  Prysmian

 Related contacts
Prysmian Cables & Systems Limited
Chickenhall Lane
Eastleigh
SO50 6YU
Tel: +44 (0)23 8029 5029
Fax: +44 (0)23 8029 5437
blue arrow pointing right   Email Julie Mould

 For latest electrical industry news, register for Voltimum's free newsletter.
Enter your email address here:
OK

Source: Prysmian

Related information

Related links
Related contacts

More News...

Insudite™ Insulation Because you need more than fire resistance
Insudite™ Insulation Because you need more than fire resistance
SeaCity Enhanced with FP Plus™
Prysmian FP installed at MediaCityUK
Prysmian launches new Afumex cable range and website
St Helens RFC takes the advantage with Prysmian FP
The Highest Standard for Enniskillen’s New Acute Hospital
Leeds’ Elland Road Scores with FP200 Gold®
Pole Position for Prysmian