Q & A of the Day – Does Part P cover holiday lodges?

BookmarkThis 19.12.2011
ECA
 

This Question of the Day concerns holiday complexes and lodges, and whether the scope of Part P of the Building Regulations applies to them. The question is answered by the ECA (Theme - Regulations & Legislation):

It depends upon the usage....
It depends upon the usage....
pixel
This Q & A is one of thousands posted in our Technical Expertise area, and answered on a daily basis by our Voltimum Experts.

Question: Can you please tell me, do holiday lodges (e.g. Centre Parks lodges etc) count as 'dwellings' under Part P of the Building Regulations?

I know of two complexes of this type where maintenance staff are employed who are not 'Part P registered' but who conduct all manner of electrical repairs.

I have been asked to perform a Periodic Inspection Report (PIR) of the lodges and want to know where I stand with regards to informing them of the requirements of Part P if applicable. Is it applicable?

There are numerous examples of bad work that I have seen, such asd 2.5mm twin & earth cable wired into the supply side of a main isolator!

Answer: No, holiday lodges and homes that are part of a managed complex/centre are not within the scope of Part P. However normal standalone homes/dwellings that are let for holidays and short breaks etc., ARE within the scope of Part P.

Note that the PIR will be changed to become the Electrical Installation Condition Report (EICR) from January 2012.

To see many more Q & A in Voltimum UK's Experts Area, please click on the link:

www.voltimum.co.uk/consult.php?universe=consult.index.questions

 Back

 Related contacts
The Electrical Contractors' Association (ECA)
ECA Head Office, ESCA House,
34 Palace Court, London W2 4HY
Tel: 020 7313 4800
Fax: 020 7221 7344
Email: electricalcontractors@eca.co.uk
Web: www.eca.co.uk
blue arrow pointing right   ECA

 For latest electrical industry news, register for Voltimum's free newsletter.
Enter your email address here:
OK

Source: ECA & James Hunt

Related information

Related contacts

More News...

Q & A of the Day – Is this 1970s electrical installation still OK today?
Q & A of the Day - Please clarify how to connect this smoke alarm circuit?
Q & A of the Day - Should a wind turbine supply cable be earthed both ends?
Q & A of the Day – What testing is needed for this altered domestic kitchen circuit?
Q & A of the Day – Is this garage sub-distribution board earth CPC adequate?
Q & A of the Day – Are smoke detectors necessary for this toilet?
Q & A of the Day – Can I use this T&E cable as the sub-distribution board CPC?
Q & A of the Day – What connection for this circuit having an extra consumer unit?
Q & A of the Day – Can I use T&E cable for this sub-distribution board CPC?