Q & A of the Day - Why is this phase conductor insulation lighting my neon screwdriver?

BookmarkThis 26.07.2010
BASEC (The British Approvals Service for Cables)
 

Our Voltimum Experts answer your questions on a daily basis in our Technical Expertise area. This Question of the Day, concerning possibly poor quality phase conductor insulation, is answered by BASEC:

This insulation will obviously cause problems!
This insulation will obviously cause problems!
pixel
Question: I'm UK electrician working in Thailand. On more than one occasion, I've come across installations where the insulation of the phase conductor is live - with enough voltage to illuminate a neon test screwdriver! Do you have an explanation for this phenomenon? I would be grateful to hear it.

Answer: Poor quality insulation can break down!

Insulation material should have a high resistance, and this is normally tested at 3kV during manufacture. Poor quality insulation can break down over time, or pinholes in the insulation can result in reduced insulation resistance values. Some types of insulation may degrade in wet conditions. Also, in a high humidity country like Thailand, there could be the effect of condensation, which can conduct significant electricity. Some neon test probes might also be subject to induced voltage, so check that too.

Any cable with insulation that has broken down sufficiently to cause a hazardous voltage to appear on other components should clearly be replaced.

To see many more Q & A in Voltimum UK's Experts Area, please click on the link:

www.voltimum.co.uk/consult.php?universe=consult.index.questions

 Back

 Related contacts
The British Approvals Service for Cables (BASEC)
23 Presley Way, Crownhill,
Milton Keynes MK8 0ES
Tel: 01908 267300
Fax: 01908 267255
Email: mail@basec.org.uk
Web: www.basec.org.uk
blue arrow pointing right   BASEC

 For latest electrical industry news, register for Voltimum's free newsletter.
Enter your email address here:
OK

Source: BASEC & James Hunt

Related information

Related contacts

More News...

Q & A of the Day - Is there a colour requirement for extension lead three-core flex?
Q & A of the Day - What is the minimum conduit size needing sealing to prevent fire spread?
Q & A of the Day - SY cable braids cannot simply be cut off and taped, can they?
Q & A of the Day - Can I use a larger cable for a final circuit than the consumer unit feed?
Q & A of the Day - CPC sizes in twin & earth cable - is there a table?
Q & A of the Day – What is the minimum conduit size needing sealing to prevent fire spread?
Q & A of the Day – Is PVC cable protection damaged by other insulations?
Q & A of the Day – Can I use a larger cable for a final circuit than the consumer unit feed?