Q & A of the Day – How high should a consumer unit be?

BookmarkThis 14.01.2009
SELECT
 

Our Voltimum Experts answer your questions on a daily basis in our Technical Expertise area. This one, about requirements for mounting heights of consumer units, is answered by SELECT:

Probably not a good place for a CU!
Probably not a good place for a CU!
pixel
Question: Can you please advise as to whether there is any legislation regarding mounting heights for consumer units in domestic situations? It has been suggested to me that these should now be installed at 1200mm AFFL. However, I can't find anything in the Scottish Building Regulations that states this.

Answer: There are no specific mounting heights for consumer units stated in either the IEE Regulations (BS7671) or in SBS Regulations.

However, BS7671:2008 - Regulation 132.12, requires that electrical equipment, which includes consumer units, should be accessible and should have sufficient space for inspection and testing etc. Therefore, consumer units should be mounted where they are readily accessible for such purposes. Mounting positions should be avoided where access is difficult i.e. some situations underneath stairs or high up on a wall.

To see many more Q & A in Voltimum UK's Experts Area, please click on the link:

www.voltimum.co.uk/consult.php?universe=consult.index.questions

 Back

 Related contacts
SELECT
The Walled Garden, Bush Estate,
Midlothian, Scotland EH26 0SB
Tel: 0131 445 5577
Fax: 0131 445 5548
Email: admin@select.org.uk
Web: www.select.org.uk
blue arrow pointing right   SELECT

 For latest electrical industry news, register for Voltimum's free newsletter.
Enter your email address here:
OK

Source: SELECT & James Hunt

Related information

Related contacts

More News...

Q & A of the Day – Can I wire to a pillar drill this way?
Q & A of the Day – Do we need to bond the metal studs in partition walls?
Q & A of the Day – Do I need earthing tails from back boxes?
Q & A of the Day – What is entered in ‘schedule of items inspected’?
Q & A of the Day - Requirements for a paint store – explosion-proof?
Q & A of the Day - Main equipotential bonding and plastic services – is bonding required?
Q & A of the Day – Guidance Note 1 - are there de-rating factors regarding cable?
Q & A of the Day - Cable routing